SnapShot Bar Code Laser Scanners User's Guide for Decoded Models: Programming Options

Pages 51 to 62 of 118, from SnapShot Bar Code Laser Scanners User's Guide for Decoded Models

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC Snapshot and Datalogic Snapshot

Page 51 read from a scan by OCR; it may hold reading errors

LOO “3<G - (LL

NOTE

For input-editing parameters, see chapter 4.

APPENDIX

Programming Options

This chapter contains information about programmable settings for the Percon SnapShot. You can use the bar codes provided in appendix E to program your SnapShot. You can also use the bar code menu on the last page of this book or another method to program it (see chapter 3).

Table A-1 lists programming |.D. numbers for predefined defaults. Table A-2 lists display and save-and-exit settings.

Table A-3 provides the following information:

|} Code Parameter is the “human” name for programming options.

L} 1.D. # is the SnapShot's “decoder” name for programming options. For example, if you wanted to set a Code 39 minimum label length, you would enter 01 when programming the SnapShot. Programming |.D. numbers given in this chapter can be used with all programming methods.

(_} Type tells what kind of setting to use for each code parameter: _} On/Off is a toggle. 1 turns the parameter on, and 0 turns it off.

(_} Value requires a two-character entry (e.g., 02 for two beeps after each good read, or 05 for a length of five).

Percon SnapShot User’s Guide

45

Page 52 read from a scan by OCR; it may hold reading errors

Programming Options

_} String uses one or more ASCII characters, followed by // to indicate the end of the string.

|_} Immediate takes effect as soon as the I.D. number is entered.

_} Acceptable Input gives the settings or range of settings that you can use for each code parameter.

|) Predefined Defaults tells how the parameter is set when you select predefined default DO, D1, or D2 (see page 12).

Table A-4 (on page 55) lists parameter settings for serial communications.

TABLE A-1 7

Predefined Defaults Setting 1.D. # Type Predefined default set 0 DO Immediate Predefined default set 1 D1 Immediate Predefined default set 2 D2 Immediate

TABLE A-2 :

Display and Save-and- Setting .D. # Type

Exit Settings Display settings (on-screen programming ED Immediate only) Save and exit EE Immediate Exit only, no save EF Immediate

46 Percon SnapShot User’s Guide

Page 53 read from a scan by OCR; it may hold reading errors

General Programming Parameters

TABLE A-3 General Programming Parameters

Predefined Code Parameter I.D. #| Type eet Defaults

DO D1 D2

Code 39 Enter 1 for On and 0 for Off. Enable 00 On/Off On or Off Off On On Minimum length 01 Value 00-50 00 00 00 Maximum length 02 Value 01-50 01 50 20 Enable checksum 03 On/Off On or Off Off Off Off Send checksum 04 On/Off On or Off Off Off Off Full ASCII mode 05 On/Off On or Off Off On On Alternate AIAG checksum 07 On/Off On or Off Off Off Off

Interleaved 2 of 5 Enter 1 for On and 0 for Off. Enable 08 On/Off On or Off Off On On Minimum length 09 Value 02-50 02 02 06 Maximum length OA Value 02-50 02 50 10 Enable checksum OB On/Off On or Off Off Off Off Send checksum le On/Off On or Off Off Off Off Use lengths 6 and 14 only OD On/Off On or Off Off Off Off

Matrix 2 of 5 Enter 1 for On and 0 for Off. Enable 10 On/Off On or Off Off On Off Minimum length 11 Value 01-50 01 01 06 Maximum length 12 Value 01-50 01 50 10 Enable checksum 13 On/Off On or Off Off Off Off Send checksum 14 On/Off On or Off Off Off Off table continues

Percon SnapShot User’s Guide 47

Page 54 read from a scan by OCR; it may hold reading errors

Programming Options

Predefined Code Parameter _ | 1I.D. #| Type eet Defaults

DO D1 D2

Standard 2 of 5 Enter 1 for On and 0 for Off. Enable 15 On/Off On or Off Off On Off Minimum length 16 Value 01-50 01 01 06 Maximum length 17 Value 01-50 01 50 10 Enable checksum 18 On/Off On or Off Off Off Off Send checksum 19 On/Off On or Off Off Off Off Use 2-bar start/stop 1A On/Off On or Off Off Off Off

Code 11 Enter 1 for On and 0 for Off. Enable 1B On/Off On or Off Off On Off Minimum length 1C Value 01-50 01 01 04 Maximum length 1D Value 01-50 01 50 10 Require 2 checksums 1E On/Off On or Off Off Off Off Send checksum(s) 1F On/Off On or Off Off On Off

Codabar/Ames Enter 1 for On and 0 for Off. Enable 20 On/Off On or Off Off On On Minimum length 21 Value 01-50 01 01 04 Maximum length 22 Value 01-50 01 50 20 Send start/stop 23 On/Off On or Off Off Off Off Codabar-to-CLSI conversion 24 On/Off On or Off Off On On table continues

48 Percon SnapShot User’s Guide

Page 55 read from a scan by OCR; it may hold reading errors

General Programming Parameters

Predefined Code Parameter _ | 1I.D. #| Type eet Defaults DO D1 D2 Codabar/Ames (continued) Enter 1 for On and 0 for Off. Wide intercharacter gaps 25 On/Off On or Off Off On Off allowed Checksum 2F Value 00 = Disable 00 00 00 01 = Enable 02 = Send MsI Enter 1 for On and 0 for Off. Enable 26 On/Off On or Off Off On Off Minimum length 27 Value 01-14 01 01 04 Maximum length 28 Value 01-14 01 14 10 Require 2 checksums 29 On/Off On or Off Off Off Off 2nd checksum Mod 11 2A On/Off On or Off Off Off Off Send checksum(s) 2B On/Off On or Off Off On Off Code 93 Enter 1 for On and 0 for Off. Enable 2C On/Off On or Off Off On On Minimum length 2D Value 00-50 00 01 02 Maximum length 2E Value 01-50 00 50 20 Universal Product Code-A (UPC-A) Enter 1 for On and 0 for Off. Enable 30 On/Off On or Off Off On On Send system digit 31 On/Off On or Off Off On On Send checksum 32 On/Off On or Off Off On Off Convert UPC-A to EAN-13 33 On/Off On or Off Off On Off table continues

Percon SnapShot User’s Guide 49

Page 56 read from a scan by OCR; it may hold reading errors

Programming Options

Predefined Code Parameter _ | 1I.D. #| Type eet Defaults

DO D1 D2

Universal Product Code-E (UPC-E) Enter 1 for On and 0 for Off. Use system digit 0 34 On/Off On or Off Off On On Use system digit 1 35 On/Off On or Off Off On On Convert UPC-E to UPC-A 36 On/Off On or Off Off On Off Send system digit 37 On/Off On or Off Off On Off Send checksum 38 On/Off On or Off Off On Off

European Article Numbering (EAN)

Japan Article Numbering (JAN) Saar (vor Oly imal war Ont

Enable EAN-8/JJAN-8 39 On/Off On or Off Off On On Enable EAN-13/JAN-13 3A On/Off On or Off Off On On Convert EAN-13 to ISBN 3B On/Off On or Off Off Off Off Send EAN/JJAN checksum 3F On/Off On or Off Off Off Off UPC, EAN, JAN Extensions Enter 1 for On and 0 for Off.

Allow 2-digit extensions 3C On/Off On or Off Off On On Allow 5-digit extensions 3D On/Off On or Off Off On On Require extensions 3E On/Off On or Off Off Off Off Code 128 Enter 1 for On and 0 for Off.

Enable 40 On/Off On or Off Off On On Minimum length 4) Value 01-50 01 01 02 Maximum length 42 Value 01-50 01 50 20 Enable UCC128 43 On/Off On or Off Off Off Off table continues

50, Percon SnapShot User’s Guide

Page 57 read from a scan by OCR; it may hold reading errors

General Programming Parameters

Predefined Code Parameter I1.D. #| Type Acceptable Defaults nput

DO D1 D2 Labelcode 4/5 Enter 1 for On and 0 for Off. Enable 52 On/Off On or Off Off On Off Convert 53 On/Off On or Off Off Off Off Other Controls Enter 1 for On and 0 for Off. Menu programming mode BO Value 00 = Off 03 03 03

01 = Serial batch 02 = Menu 03 = Both Autoterminator B1 Value Any single (CR) (CR) (CR) ASCII character (00 = Off) ASCII capital to lowercase B2 On/Off On or Off Off Off Off Intercharacter delay B3 Value 00-99 00 00 00 (milliseconds)

CCD/laser redundancy B4 On/Off On or Off Off Off Off Send assigned symbology B5 On/Off On or Off Off On Off identifiers* *A = UPC-A D=M2of5 G = EAN-8 J = Code 11 N = Labelcode 4/5 B=/20f5 E = UPC-E H = MSI K = Code 128 C = Code 39 F=S2of5 | = Codabar/Ames M = EAN-13 Bar code preamble B6 String r // § // Bar code postamble B7 String r // = // TAny supported keyboard keys, up to the maximum length supported by available total memory (about 80 characters) SCODEID // (includes a space after CODEID) ** PERCON// (includes a space before PERCON)

table continues

Percon SnapShot User’s Guide 51

Page 58 read from a scan by OCR; it may hold reading errors

Programming Options

Predefined Code Parameter I.D. #| Type Acceptable Defaults nput DO D1 D2 Other Controls (continued) Enter 1 for On and 0 for Off. Good-read tone B8 Value 00 = 3600 Hz 04 04 04 01 = 3840 Hz 02 = 4114 Hz 03 = 4430 Hz 04 = 2400 Hz 05 = 2618 Hz 06 = 2880 Hz 07 = 3200 Hz Good-read number of beeps} B9 Value 01-04 01 01 01 Good-read beep duration BA Value 00 = 0.07 sec. 00 00 00 01 = 0.13 sec. 02 = 0.18 sec. 03 = 0.36 sec. End-of-transmission beep BB On/Off On or Off Off On Off Beeper volume BC Value 00 = Off 03 03 03 01 = Low 02 = Medium 03 = High Interfunction delay BE Value 00-99 00 00 00 (milliseconds) Use numeric keypad BF On/Off On or Off Off Off Off Strip Motorola data identifiers | D3 On/Off On or Off Off Off Off table continues

52

Percon SnapShot User’s Guide

Page 59 read from a scan by OCR; it may hold reading errors

General Programming Parameters

Predefined Code Parameter _ | 1I.D. #| Type Acceptable Defaults nput DO D1 D2 Other Controls (continued) Enter 1 for On and 0 for Off. Trigger modes for wedge D4 Value 00 = Normal 00 00 00 mode (not used in wand 01 = Autoscan emulation mode) 02 = Multiscan Timing speed for wand D4 Value 00 = 500 us 00 00 00 emulation mode (CO=03) 01 = 300 us 02 = 200 pS Require keyboard D5 On/Off On or Off On On On Autoscan timeout for wedge} D6 Value | 01-99 (minutes) | 30 30 30 mode (not used in wand 00 = 256 min. emulation mode) Idle mode timeout D6 Value | 01-99 (seconds) 30 30 30 00 = Off CTRL out at power-up D7 On/Off On = High On On On Off = Low table continues

Percon SnapShot User’s Guide 53

Page 60 read from a scan by OCR; it may hold reading errors

Programming Options

Predefined Code Parameter _ | 1I.D. #| Type eet Defaults DO D1 D2 Other Controls (continued) Enter 1 for On and 0 for Off. Host device | CO | Value | * | None | None | None

*00 = IBM PC/XT (international keyboard)

01 = IBM AT, PS/2 30-286, 50, 50Z, 60, 70, 80, 90, 95 (international keyboard)

02 = IBM PS/2 25, 30 (international keyboard) Note: Settings 00-02 work with DOS only. They transmit the ASCII character set and are not full-keyboard compatible.

03 = Wand emulation mode

10 = IBM PC/XT (U.S. keyboard)

11 = IBM AT, PS/2 30-286, 50, 50Z, 60, 70, 80, 90, 95 (U.S. keyboard); ADDS; IDEA 276, 277,

486, 487; I/O CORP 2476; NCR 2900

12 = IBM PS/2 25, 30 (U.S. keyboard)

15 = IBM and Telex terminals (102-key keyboard)

17 = IBM and Telex terminals (122-key keyboard); Decision Data models 3496 and 3781

21 = Macintosh ADB (U.S. keyboard)

25 = Data General D213, D413

32 = TeleVideo

40 = DEC

42 = NEC PowerMate Note: The host devices listed above were supported at the time this user’s guide was printed. Additional devices may also be supported. For current information, please contact your dealer or Percon Technical Support (see page 79).

54

Percon SnapShot User’s Guide

Page 61 read from a scan by OCR; it may hold reading errors

Serial Parameters

TABLE A-4

Serial Parameters

Acceptable Predefined Code Parameter I.D. #| Type Input Default (C8) Serial Parameters Enter 1 for On and 0 for Off. Data type CO Value 50 = ASCII 50 51 = PC scan codes Baud rate C1 Value 00 = 300 05 01 = 600 02 = 1200 03 = 2400 04 = 4800 05 = 9600 06 = 19200 07 = 38400 08 = 57600 Data bits C2 Value 07 = 7 Bits 08 08 = 8 Bits Parity C3 Value 00 = None 00 01 = Mark 02 = Space 03 = Odd 04 = Even Stop bits C4 Value 01 = 1 Bit 01 02 = 2 Bits Xon/Xoff handshaking C5 On/Off On or Off Off Predefined serial defaults C8 Protocol CA Value 00 = EOR only 00 01 = ACK/NAK End-of-record (EOR) character] CC Value Any single (CR) ASCII character table continues

Percon SnapShot User’s Guide 55

Page 62 read from a scan by OCR; it may hold reading errors

Programming Options

Acceptable Predefined Code Parameter I.D. #| Type Input Default (C8)

Serial Parameters (continued) Enter 1 for On and 0 for Off. Timeout CD Value 01-99* 03

00 = 2.55 sec. Require host response CE On/Off On or Off Off (laser models only) Use host-controlled CF On/Off On or Off Off indicators (laser models only)

*710-millisecond increments, the default setting (03) means 30 milliseconds

56

Percon SnapShot User’s Guide