Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 14

SnapShot Bar Code Laser Scanners User's Guide for Decoded Models: Input Editing, pages 43 to 50

Pages 43 to 50 of 118, from SnapShot Bar Code Laser Scanners User's Guide for Decoded Models

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC Snapshot and Datalogic Snapshot

Page 43 read from a scan by OCR; it may hold reading errors

Understanding Output Sequences

Using Extra Fields

You can define up to 16 extra fields for input editing. Use the extra fields to include text strings or keyboard actions. For example, by defining one field to contain the word aisle, another field to contain the word bin, a third field to contain a tab, and another field to contain a space, you can change N21263 to aisle N21 bin 263

INN | Ze t282! number of NO T & Characters that can be stored in all string commands combined is Table 4-4 lists ID numbers and predefined defaults for extra fields. You can 120. change your SnapShot’s settings for these parameters using the bar code menu, bar code batch, serial batch, or on-screen method of programming.

You can include the value for each extra field in the output sequence of any or all of the qualification definitions.

TABLE 4-4 Extra-Field Parameters Predefined defaults Parameter ID # Type DO D1 D2

Extra field 0 60 String // Acc#// // Extra field 1 61 String // //* // Extra field 2 62 String // If // Extra fields 3-16 63-6F8 String // // //

*Two spaces

TA comma followed by a space

Extra field 3 = 63 Extra field 8 = 68 Extra field 4 = 64 Extra field 9 = 69 Extra field 5 = 65 Extra field A = 6A

Extra field D = 6D Extra field E = 6E Extra field F = 6F

Extra field 6 = 66 Extra field 7 = 67

Extra field B = 6B Extra field C = 6C

Percon SnapShot User’s Guide

37

Page 44 read from a scan by OCR; it may hold reading errors

Input Editing

TABLE 4-5 Output-Redirection Settings

An Input Editing Example

Redirecting Output

After input editing, data is normally output to the host computer or terminal. You can include output-redirection commands or system commands in the output sequence to redirect the data output (see table 4-5).

Value Used in Output Sequence Effect

Switches output back to the host after data has been

210 redirected

Redirects data as control commands to be sent to the

91 system's host-controlled indicator (HCI) parser (see page 25)

| ill ill lll | To read the bar codes in this example, your SnapShot must accept Code 39 bar

No T, codes with a maximum length of 26 characters. Scan the following bar code to reset your SnapShot to predefined default D2 and set the maximum length for Code 39 bar codes to 26:

$ - D288 22 6 E E *

* $ + Let’s say you are the head of security for a large manufacturing company. Each employee in your company has an identification badge with a Code 39 bar code containing the employee’s first name and last name, a five-digit employee number that begins with 0, and sometimes additional information. Names, numbers, and other information in the bar codes are separated by periods, as in the following example:

38, Percon SnapShot User’s Guide

Page 45 read from a scan by OCR; it may hold reading errors

An Input Editing Example

* S ALLEY . ROGERS . &©@ 18 3 6 .%M GR *

To enter certain areas of the building, employees must present their badges to a security guard, who scans the bar codes with a Percon SnapShot attached to a computer terminal. The information output to the computer also includes the location of the security station. The output is in the following format:

Last name, First name Emp. # Location

Today you are installing a SnapShot at a security station for Area M, and you need to program the SnapShot to output the data in the proper format. Using the example above, you want the output to be as follows:

Rogers, Sally 1836 Area M

To get the results you want, you need to complete three steps.

Step 1: Create a Qualification Definition

The definition will require the input to be Code 39 data of any length and will break that data down into seven fields, including (1) first name, (3) last name, (5) employee number with the leading zero dropped off, and (7) other information, as shown below:

* S ALLY . ROGERS . &@ 183 6.%M GR * eee ile! u - - 4

|

1 2 3 4 5 6 7

Any input that doesn’t meet the definition criteria will not be edited.

Percon SnapShot User’s Guide 39

Page 46 read from a scan by OCR; it may hold reading errors

Input Editing

TABLE 4-6 Parameter Settings for the Example

Table 4-6 lists the parameters and values you need to use. If you are using predefined defaults (see page 12), you need to program only the parameters whose values are different from the defaults. For example, the D1 default setting for ID #71 (definition 1 symbology) is C (Code 39); so if your SnapShot is using the D1 settings, you do not need to set ID #71.

Parameter | ID# | Value Meaning Enable Use definition 1 to filter incoming data. ar 70 1 definition 1 Symbology 71 C Only Code 39 input will be edited. Record length The incoming data can contain any number of 72 00 characters. Number of The incoming data contains seven fields. . 73 07 fields Field 1 7A 00(00) The first field can be of any length and can begin with any character. Field 2 The second field is exactly one character long and 75 01. . . that character is a period. Field 3 46 00(00) The third field can be of any length and can begin with any character. Field 4 The second field is exactly two characters long and 77 02. . . . the first character is a period. Field 5 78 04(00) The fifth field is exactly four characters long and can begin with any character. Field 6 The sixth field is exactly one character long and 79 01. : . that character is a period. Field 7 Ih 00(00) The seventh field can be of any length and can begin with any character.

40 Percon SnapShot User’s Guide

Page 47 read from a scan by OCR; it may hold reading errors

An Input Editing Example

If you are using the bar code batch programming method and the D2 predefined defaults, your bar codes for the definition should look like the following:

* 1 7 1 . EE

$ + $ - 7 Q 7 1C0C 7 3 & 7 5 ¥ x §$ $6 - 7 78 2.7828 4% U 7928 1. EE *

% Notice that the bar codes do not include settings for record length or for fields 1, 3, and 7. Since these parameters use the defaults, it is not necessary to include them in the bar codes. Also notice the %U in the second bar code. This is the Code 39 equivalent for the null character, which is used in place of 00 in bar code batch programming.

*

+

Step 2: Program Extra Fields

Set parameters for three extra fields to contain the following:

_} The security station's location

(_} A comma and a space to separate the first name from the last name _} A tab to separate columns in the output

Table 4-7 lists the parameters and data strings you need to use. Each string ends with the end-of-string character (//).

Percon SnapShot User’s Guide

Al

Page 48 read from a scan by OCR; it may hold reading errors

Input Editing

TABLE 4-7 :

Parameter Settings Parameter | ID # String Contents for the Extra Fields Extra field 0 60 Area M//_ |The location of the security station Extra field 1 61 /// A comma followed by a space Extra field 2 62 (TABR)//_|A tab character

Your bar codes for the extra-field settings should look like the following:

* 6 &@ A R A M / E E *

+ - + E + * - 6 1 / -L / / 62 $ | / / E E *

Notice the use of the plus symbols (+) before the R, the E, and the second A. These cause the letters to be output as lowercase (a, r, and e). In the second bar code, /L is the Code 39 equivalent for a comma, and $1 is the Code 39 equivalent for a tab character. Also notice that each extra-field setting ends with an end-of-string character (//).

+ /

+

42 Percon SnapShot User’s Guide

Page 49 read from a scan by OCR; it may hold reading errors

An Input Editing Example

N O TE

The output sequence must be programmed with a single bar code, since you cannot break a string into two bar codes.

Step 3: Program the Output Sequence Enter the following codes: 03610162056260B1// where

03 is field 3 (last name)

61 is extra field 1 (comma and space)

01 is field 1 (first name)

62 is extra field 2 (tab)

05 is field 5 (employee number without the leading 0) 62 is extra field 2 (tab)

60 is extra field 0 (“Area M”)

B1 is the autoterminator (a carriage return)

// is the end-of-string character

Your bar code for the output sequence should look like the following:

* + $ - 7 C 3.6 «1 6 2 5 6 2 68 B11 / EE *

QR 1 Once you've completed these steps, your SnapShot should be able to read the bar code on each employee’s badge and report that the employee has entered Area M.

$ Q Q /

Percon SnapShot User’s Guide

43

Page 50