The text of a manual · part 2 of 2
QuickScan QS6500BT General Purpose Handheld Linear Imager Bar Code Reader with Bluetooth Wireless Technology Quick Reference Guide, pages 11 to 20
Pages 11 to 20 of 20
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS6500BT and Datalogic QS6500BT Base
Page 11
Battery Warnings and Cautions
WARNING
Do not discharge the battery using any device except for the linear imager. When the battery is used in devices other than the linear imager, it may damage the battery or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become hot, explode or ignite and cause serious injury. Lithium-ion battery packs may get hot, explode or ignite and cause serious injury if exposed to abusive conditions. Be sure to follow the safety warnings listed below: • Do not place the battery pack in fire or heat. • Do not connect the positive terminal and negative terminal of the battery pack to each other with any metal object (such as wire). • Do not carry or store the battery pack together with metal objects. • Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks. • Do not solder directly onto the battery pack. • Do not expose the battery pack to liquids, or allow the battery to get wet. In the event the battery pack leaks and the fluid gets into your eye, do not rub the eye. Rinse well with water and immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye.
Quick Reference Guide
3
Page 12
Always charge the battery at 32°–113°F (0°–45°C) temperature range.
CAUTION
Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the linear imager and void your warranty. Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite. Do not place the battery in or near fire, on stoves or other high temperature locations. Do not place the battery in direct sunlight, or use or store the battery inside cars in hot weather. Doing so may cause the battery to generate heat, explode or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy. Do not place the battery in microwave ovens, high-pressure containers or on induction cookware. Immediately discontinue use of the battery if, while using, charging or storing the battery, the battery emits an unusual smell, feels hot, changes color or shape, or appears abnormal in any other way.
4
QuickScanTM QS6500BT
Page 13
Power Supply Models require either a Listed class II or class III with a Limited Power Source (LPS). For the safety certification to be valid, class III input power sources must be IEC/EN60950-1 (EN 60335series, EN 60065 or relevant) approved. Input: 100 - 240 VAC Output: 9 - 12 VDC Max. Current: 2.5 A Max. Power: 30 W For USB Power Off Terminal applications, attach to USB 1.0, 1.1 or 2.0 host device ONLY.
NOTE
LED and Beeper Indications Some LED and Beeper indications are user-configurable. Those listed in the following table are standard default settings. See the Product Reference Guide (PRG) for programming information. Condition Powering On Ready to Operate Good Read Error Indication
Quick Reference Guide
LED
Beeper
Bright Green Flash Configurable as OFF or ON DIM Bright Green Flash Red Flash
One Beep None One Beep None
5
Page 14
How to Scan The figure below shows the right and wrong ways to scan a bar code.
1
1
2 2
1. The linear imager must be pointed at a slight angle to the bar code so that the light reflected off the bar code can be “seen” by the linear imager. Do not hold the linear imager perpendicular to the bar code. 2. The targeting beam must cross the entire label. The linear imager cannot read the bar code data without seeing the entire label. Scanning PDF417 Bar Codes To read a PDF417 bar code, aim the targeting beam at the top of the bar code, and in a smooth motion, scan down through the bar code. You will hear a series of ticks, followed by a final beep when the bar code’s content has been completely decoded. You may need to sweep the bar code more than once in order to complete the read.
6
QuickScanTM QS6500BT
Page 15
Troubleshooting If the linear imager is not operating properly, the following checks should be performed: 1. The BT linear imager uses an internal battery and if the battery is fully depleted or failed, the linear imager will not operate. Exchange the battery with a known good unit and retest the linear imager.
uct Prod ence r Refe ide Gu
4
1
2
3
5
2. Verify the interface cable is securely attached to the host. Consult your technical support personnel or refer to your host system manual to verify the proper connection for the linear imager. 3. Verify that the interface cable is securely attached to the Base Station. 4. Check that the labels are of sufficient quality to be recognized by the linear imager. Wrinkled, smudged, or torn labels can cause the linear imager to not read at all. Scan a known good label to check the linear imager's read operation. 5. Ensure that the Base Station's interface type is compatible with the host terminal by consulting your POS system manual and/or the linear imager’s Product Reference Guide found on the CD included with your linear imager.
Quick Reference Guide
7
Page 16
6. Verify that the Base Station power cable is securely attached and the external power adapter is plugged in. If the linear imager still does not function properly, contact your local supplier or Datalogic Customer Support Services.
Statement of Compliance This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference; and 2. This device must accept any interference received, including interference that may cause undesired operation. FCC Class B Compliance Statement This Equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
8
•
Reorient or relocate the receiving antenna
•
Increase the separation between the equipment and receiver
QuickScanTM QS6500BT
Page 17
•
Connect the equipment into an outlet on a circuit different from that to which receiver is connected
•
Consult the dealer or an experienced radio I TV technician for help.
FCC Caution statement "The User is cautioned that changes or modifications not expresely approved by the part responsible for compliance could void the user's authorify to operate the equipment." LED Class CLASS 1 LED PRODUCT
APPARECCHIO LED CLASSE 1
LED KLASSE 1
APPAREIL A LED DE CLASSE 1 EN60825-1/All:2001
Quick Reference Guide
9
Page 18
NOTES
10
QuickScanTM QS6500BT
Page 19
EC DECLARATION OF CONFORMITY Datalogic hereby declares that the apparatus specified below and as referenced in the EC Type Approval Certificate has been tested and found compliant to the following European Council Directives and harmonized Standards. Equipment Type: Handheld Barcode Scanning Equipment Apparatus: QuickscanTM QS6500BT with Base Station Manufactured by: Placed into EU Service:
Datalogic Scanning, Inc. 959 Terry St. Eugene, Oregon USA, 541-683-5700 Oct 2002 under PSC logo, May 2007 under Datalogic logo. Updated June 2009
EMC 2004/1 08/EC (2004) Low Voltage 2006/95/EC (2006) EN 300 328 (2006) Council Directives: EN 301489-1/17 (2008) R&TTE 1999/5/EC (1999) Battery 2006/66/EC (2006) amended 2008/12/EC (2008) Standards: EN 55022: 2006 (Class B)
Description: Generic Emissions
AN/NZS CISPR22:2006
Generic Emissions
EN 301489-1/17:2008
Generic Immunity to EN61000 4-2: 1995 + A1:1998 + A2:2001 (ESD), 4-3: 2006 + A1:2008 (susceptibility), 4-4: 2004 (EFT), 4-5: 2006 (surge), 4-6: 2007 (conducted immunity) 4-11: 2004 (VDl)
EN61000-3-2:2006
Harmonic Current (power supply)
EN61000-3-3 : 1995 + A1:2001 + A2:2005
Voltage Fluctuation/Flicker (power supply)
EN/IEC 60950-1 :2001/ CB
Safety of ITE
United Nations
Manual of Tests and Criteria, Section 38.3
ST/SG/AC.10/11/Rev.3
Lithium batteries
UL2054
Safety for household and commercial batteries A technical construction file for this apparatus is retained at the above address.
Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC: English:
This apparatus is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC
Français:
Cet équipement répond aux exigences et provisions de la Directive 1999/5/EC.
Deutsch:
Diese Geräte entsprechen den Anforderungen und anderen relevanten Bestinunungen der Richtlinie 1999/5/EC.
Italiano:
Questa apparecchiatura rispetta i requisiti essenziali e Ie altre clausole rilevanti della Direttiva 1999/5/CE.
Espanol:
Este equipo cumple con los requisitos esenciales y otras provisiones relevantes de la Directiva 1999/5/EC.
June 11, 2009 Brad West Vice President, Supply Chain Operations Datalogic Scanning, Inc.
Page 20
Australia Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com
Japan Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com
France and Benelux Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com
Latin America Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com
Germany Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.com
Singapore Datalogic Scanning Singapore PTE LTD Telephone: (65) 6435-1311 singapore.scanning@datalogic.com
India Datalogic Scanning India Telephone: 91- 22 - 64504739 india.scanning@datalogic.com
Iberia Datalogic Scanning SAS Sucursal en España Telephone: 34 91 746 28 60 spain.scanning@datalogic.com
Italy Datalogic Scanning SpA Telephone: [39] (0) 39/62903.1 italy.scanning@datalogic.com
United Kingdom Datalogic Scanning LTD Telephone: 44 (0) 1582 464900 uk.scanning@datalogic.com www.scanning.datalogic.com Datalogic Scanning, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140
R44-3041 (Rev. A) ©2004-2009 Datalogic Scanning, Inc.
7/09