Page 28
General Features
START
BAR
CODE
END NUL
LENGTH
140msec
160msec
180msec
200msec
3-10 QuickScan® QS6500/QS6500BT
Page 29
LED and Beeper Indicators
Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are five selectable volumes, with each volume increment adding approximately five decibels to the previous level. START VOLUME
BARCODE
Off
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
END
Product Reference Guide
3-11
Page 30
General Features
Scanning/Imaging Features Scan Mode Selects the scan operating mode for the imager. Selections are: •
Good read off, The trigger must be pressed to activate scanning. The light source stops scanning when there is a successful read or no bar code is decoded after the ”Imager Timeout” has elapsed.
•
Momentary, The trigger acts as a switch. Pressing the trigger activates scanning; releasing it stops scanning.
•
Alternate, The trigger acts as a toggle switch. Pressing the trigger activates scanning; pressing it a second time stops scanning
•
Timeout off, The trigger must be pressed to activate scanning, The imager stops scanning if no barcode is decoded within the time duration set for the ”Imager Timeout” period.
•
Stand Mode, The imager continuously reads regardless of whether the trigger is pressed or ”Imager Timeout” has elapsed.
3-12
QuickScan® QS6500/QS6500BT
Page 31
Scanning/Imaging Features
Scan Mode, continued START MODE
BARCODE
Good read off
Momentary
Alternate
Timeout off
Stand mode
END
Product Reference Guide
3-13
Page 32
General Features
Stand Mode LED When this feature is set to ON while in stand mode, the illumination LEDs go to a dim state after a timeout of reading no labels. When set to OFF in stand mode, the illumination LEDs go off after a timeout of reading no labels. In both cases, the illumination LEDs come back on when something passes in front of the imager. START STATE
BARCODE
LED OFF
LED ON
END
Scan Illumination LED Timeout Limits the time following pressing the trigger that the illumination LED (aiming light) is lit. Disabling this feature turns the illumination off. Selecting “Continue” means the imager always keeps reading regardless of whether the trigger button is pressed or the standby duration has elapsed. START DURATION
BARCODE
Disable
30 Seconds
60 Seconds
3-14
QuickScan® QS6500/QS6500BT
Page 33
Scanning/Imaging Features START DURATION
BARCODE
90 Seconds
120 Seconds
150 Seconds
180 Seconds
Continue
END
Inverted Image Scan With this option enabled, the imager will scan black/white bar codes with a white/black background. START MODE
BARCODE
Disable Enable END
Product Reference Guide
3-15
Page 34
General Features
Global Features Global Minimum Code Length Global minimum length can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. bar code labels with lengths exceeding these limits will be rejected. Ensure that the minimum-length setting is no greater than the maximum-length setting; otherwise, the labels of the symbology will not be readable. In particular, you can set the same value for both minimum and maximum lengths to force decoding of only fixed-length bar codes. This setting has no effect on certain symbologies of fixed length. START MODE
BARCODE Global Minimum length can be set from 0 to 255. To set this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set Global Minimum Length,” followed by the digits from the Alphanumeric table in Appendix B, AlphaNumeric Pad representing your desired minimum length. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 4
Set Global Minimum Length SET
END
3-16
QuickScan® QS6500/QS6500BT
Page 35
Global Features
Global Maximum Code Length Global maximum length can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. bar code labels with lengths exceeding these limits will be rejected. Ensure that the minimum-length setting is no greater than the maximum-length setting; otherwise, the labels of the symbology will not be readable. In particular, you can set the same value for both minimum and maximum lengths to force decoding of only fixed-length bar codes. This setting has no effect on certain symbologies of fixed length. START MODE
BARCODE Global Maximum length can be set from 0 to 255. To set this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set Global Maximum Length,” followed by the digits from the Alphanumeric table in Appendix B, AlphaNumeric Pad representing your desired maximum length. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 64
Set Global Maximum Length SET
END
Product Reference Guide
3-17
Page 36
General Features
NOTES
3-18
QuickScan® QS6500/QS6500BT