General Features

START

BAR

CODE

END NUL

LENGTH

140msec

160msec

180msec

200msec

3-10 QuickScan® QS6500/QS6500BT

Page 29

LED and Beeper Indicators

Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are five selectable volumes, with each volume increment adding approximately five decibels to the previous level. START VOLUME

BARCODE

Off

Level 1

Level 2

Level 3

Level 4

Level 5

Level 6

Level 7

END

Product Reference Guide

3-11

Page 30

General Features

Scanning/Imaging Features Scan Mode Selects the scan operating mode for the imager. Selections are: •

Good read off, The trigger must be pressed to activate scanning. The light source stops scanning when there is a successful read or no bar code is decoded after the ”Imager Timeout” has elapsed.

•

Momentary, The trigger acts as a switch. Pressing the trigger activates scanning; releasing it stops scanning.

•

Alternate, The trigger acts as a toggle switch. Pressing the trigger activates scanning; pressing it a second time stops scanning

•

Timeout off, The trigger must be pressed to activate scanning, The imager stops scanning if no barcode is decoded within the time duration set for the ”Imager Timeout” period.

•

Stand Mode, The imager continuously reads regardless of whether the trigger is pressed or ”Imager Timeout” has elapsed.

3-12

QuickScan® QS6500/QS6500BT

Page 31

Scanning/Imaging Features

Scan Mode, continued START MODE

BARCODE

Good read off

Momentary

Alternate

Timeout off

Stand mode

END

Product Reference Guide

3-13

Page 32

General Features

Stand Mode LED When this feature is set to ON while in stand mode, the illumination LEDs go to a dim state after a timeout of reading no labels. When set to OFF in stand mode, the illumination LEDs go off after a timeout of reading no labels. In both cases, the illumination LEDs come back on when something passes in front of the imager. START STATE

BARCODE

LED OFF

LED ON

END

Scan Illumination LED Timeout Limits the time following pressing the trigger that the illumination LED (aiming light) is lit. Disabling this feature turns the illumination off. Selecting “Continue” means the imager always keeps reading regardless of whether the trigger button is pressed or the standby duration has elapsed. START DURATION

BARCODE

Disable

30 Seconds

60 Seconds

3-14

QuickScan® QS6500/QS6500BT

Page 33

Scanning/Imaging Features START DURATION

BARCODE

90 Seconds

120 Seconds

150 Seconds

180 Seconds

Continue

END

Inverted Image Scan With this option enabled, the imager will scan black/white bar codes with a white/black background. START MODE

BARCODE

Disable Enable END

Product Reference Guide

3-15

Page 34

General Features

Global Features Global Minimum Code Length Global minimum length can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. bar code labels with lengths exceeding these limits will be rejected. Ensure that the minimum-length setting is no greater than the maximum-length setting; otherwise, the labels of the symbology will not be readable. In particular, you can set the same value for both minimum and maximum lengths to force decoding of only fixed-length bar codes. This setting has no effect on certain symbologies of fixed length. START MODE

BARCODE Global Minimum length can be set from 0 to 255. To set this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set Global Minimum Length,” followed by the digits from the Alphanumeric table in Appendix B, AlphaNumeric Pad representing your desired minimum length. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 4

Set Global Minimum Length SET

END

3-16

QuickScan® QS6500/QS6500BT

Page 35

Global Features

Global Maximum Code Length Global maximum length can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. bar code labels with lengths exceeding these limits will be rejected. Ensure that the minimum-length setting is no greater than the maximum-length setting; otherwise, the labels of the symbology will not be readable. In particular, you can set the same value for both minimum and maximum lengths to force decoding of only fixed-length bar codes. This setting has no effect on certain symbologies of fixed length. START MODE

BARCODE Global Maximum length can be set from 0 to 255. To set this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set Global Maximum Length,” followed by the digits from the Alphanumeric table in Appendix B, AlphaNumeric Pad representing your desired maximum length. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 64

Set Global Maximum Length SET

END

Product Reference Guide

3-17

Page 36

General Features

NOTES

3-18

QuickScan® QS6500/QS6500BT