Page 259
Standard 2 of 5
Standard 2 of 5, continued START STATE
BARCODE
Set Standard 2 of 5 Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET
END
Product Reference Guide
6-171
Page 260
Symbologies
Code 16K The following options apply to the Code 16K symbology.
Disable/Enable Code 16K When this feature is disabled, the imager will not read Code 16K bar codes. START STATE
BARCODE
Disable Code 16K Enable Code 16K END
6-172
QuickScan® QS6500/QS6500 BT
Page 261
Code 16K
Code 16K, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.
NOTE
The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.
START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET
END
Product Reference Guide
6-173
Page 262
Symbologies
Code 16K, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted Code 16K bar code data depending on how this feature is enabled. Example: Setting the Code 16K Code I.D.
To configure this feature: 1. Determine which character(s) you would like to use to represent the Code 16K symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “C” to represent Code 16K. The value from the table corresponding to ‘’C’ is 43. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET Code 16K CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘4’ and ‘3’ (the value determined in an earlier step to represent ‘C’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE
7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned Code 16K labels would appear as follows: Scanned bar code data:
0123456789123
Resulting message string output: C0123456789123
6-174
QuickScan® QS6500/QS6500 BT
Page 263
Code 16K
Code 16K, continued START STATE
BARCODE
Set Code 16K Code I.D. Character(s)
NO DEFAULT SETTING FOR THIS FEATURE Select 0000 to disable Code ID for this symbology only.
SET
END
Product Reference Guide
6-175
Page 264
Symbologies
Code 16K, continued Code 16K Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever a Code 16K bar code is scanned.
NOTE
The options in this section set Data Group Characters for the Code 16K symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).
To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET CODE 16KDATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever a Code 16K bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.
6-176
QuickScan® QS6500/QS6500 BT
Page 265
Code 16K
Code 16K, continued START STATE
BARCODE
Set Code 16K Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET
END
Product Reference Guide
6-177
Page 266
Symbologies
China Post The following options apply to the China Post symbology.
Disable/Enable China Post When this feature is disabled, the imager will not read China Post bar codes. START STATE
BARCODE
Disable China Post Enable China Post END
6-178
QuickScan® QS6500/QS6500 BT
Page 267
China Post
China Post, continued Minimum/Maximum Code Length Many symbologies have their own maximum and minimum code length, which can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with lengths below the minimum or above the maximum will be rejected. If the maximum code length is set to zero, the global maximum is in effect. If the minimum code length is set to zero, the global minimum is in effect.
NOTE
Ensure that the minimum length setting is not greater than the maximum length setting; otherwise, all the labels of the symbology will be unreadable. You can set the same value for both minimum and maximum length to force decoding of only bar codes of a certain length.
START MODE
BARCODE
Set Maximum Length DEFAULT SETTING FOR THIS FEATURE: 11 (0BHex) Set Minimum Length DEFAULT SETTING FOR THIS FEATURE: 11 (0BHex) SET
END
Product Reference Guide
6-179
Page 268
Symbologies
China Post, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.
NOTE
The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.
START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET
END
6-180
QuickScan® QS6500/QS6500 BT