Page 239

UK-Plessey

UK-Plessey, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.

NOTE

The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.

START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET

END

Product Reference Guide

6-151

Page 240

Symbologies

UK-Plessey, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted UK/Plessey bar code data depending on how this feature is enabled. Example: Setting the UK/Plessey Code I.D.

To configure this feature: 1. Determine which character(s) you would like to use to represent the UK/Plessey symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “@” to represent UK/Plessey. The value from the table corresponding to ‘’@’ is 40. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET UK/PLESSEY CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘4’ and ‘0’ (the value determined in an earlier step to represent ‘@’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE

7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned UK/Plessey labels would appear as follows: Scanned bar code data:

0123456789123

Resulting message string output: @0123456789123

6-152

QuickScan® QS6500/QS6500 BT

Page 241

UK-Plessey

UK-Plessey, continued START STATE

BARCODE

Set MSI/Plessey Code I.D. Character(s)

DEFAULT SETTING FOR THIS FEATURE: @ (40 hex) Select 0000 to disable Code ID for this symbology only.

SET

END

Product Reference Guide

6-153

Page 242

Symbologies

UK-Plessey, continued UK-Plessey Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever a UK-Plessey bar code is scanned.

NOTE

The options in this section set Data Group Characters for the UK-Plessey symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).

To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET UK-PLESSEY DATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever a UK-Plessey bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.

6-154

QuickScan® QS6500/QS6500 BT

Page 243

UK-Plessey

UK-Plessey, continued START STATE

BARCODE

Set UK-Plessey Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET

END

Product Reference Guide

6-155

Page 244

Symbologies

Telepen The following options apply to the Telepen symbology.

Disable/Enable Telepen When this feature is disabled, the imager will not read Telepen bar codes.

Checksum Verification When enabled, the imager will verify the check sum of the labels.

Checksum Transmit When this option is enabled, the imager will transmit the checksum.

Format The Telepen symbology contains options for numeric only or full ASCII.

6-156

QuickScan® QS6500/QS6500 BT

Page 245

Telepen

Telepen, continued START STATE

BARCODE

Disable Telepen Enable Telepen Disable Checksum Verification Enable Checksum Verification Disable Checksum Transmission Enable Checksum Transmission Format = Numeric Only Format = Full ASCII END

Product Reference Guide

6-157

Page 246

Symbologies

Telepen, continued Minimum/Maximum Code Length Many symbologies have their own maximum and minimum code length, which can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with lengths below the minimum or above the maximum will be rejected. If the maximum code length is set to zero, the global maximum is in effect. If the minimum code length is set to zero, the global minimum is in effect..

NOTE

Ensure that the minimum length setting is not greater than the maximum length setting; otherwise, all the labels of the symbology will be unreadable. You can set the same value for both minimum and maximum length to force decoding of only bar codes of a certain length.

START MODE

BARCODE

Set Maximum Length DEFAULT SETTING FOR THIS FEATURE: 00 Set Minimum Length DEFAULT SETTING FOR THIS FEATURE: 00 SET

END

6-158

QuickScan® QS6500/QS6500 BT

Page 247

Telepen

Telepen, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.

NOTE

The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.

START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET

END

Product Reference Guide

6-159

Page 248

Symbologies

Telepen, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted Telepen bar code data depending on how this feature is enabled. Example: Setting the Telepen Code I.D.

To configure this feature: 1. Determine which character(s) you would like to use to represent the Telepen symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “S” to represent Telepen. The value from the table corresponding to ‘’S’ is 53. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET TELEPEN CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘5’ and ‘3’ (the value determined in an earlier step to represent ‘S’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE

7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned Telepen labels would appear as follows: Scanned bar code data:

0123456789123

Resulting message string output: S0123456789123

6-160

QuickScan® QS6500/QS6500 BT