The text of a manual · part 16 of 38
QuickScan QS6500/QS6500BT Product Reference Guide: Symbologies, pages 139 to 148
Pages 139 to 148 of 336, from QuickScan QS6500/QS6500BT Product Reference Guide
The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS6500BT and Datalogic QS6500BT Base
Page 139
RSS Expanded
RSS Expanded, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.
NOTE
The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.
START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending
SET ³
.
END
Product Reference Guide
6-51
Page 140
Symbologies
RSS Expanded, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted RSS Expanded bar code data depending on how this feature is enabled. Example: Setting the RSS Expanded Code I.D.
To configure this feature: 1. Determine which character(s) you would like to use to represent the RSS Expanded symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “RX” to represent RSS Expanded. The value from the table corresponding to ‘’R’ is 52 and the value for ‘X’ is 58. These values will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET RSS Expanded CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘5’ and ‘2’ (the value determined in an earlier step to represent ‘R’). Then scan the bar codes ‘5’ and ‘8’ (hex equivalent for ‘X’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE
7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned RSS Expanded labels would appear as follows: Scanned bar code data:
0123456789123
Resulting message string output: RX0123456789123 6-52
QuickScan® QS6500/QS6500 BT
Page 141
RSS Expanded
RSS Expanded, continued START STATE
BARCODE
Set RSS Expanded Code I.D. Character(s)
DEFAULT SETTING FOR THIS FEATURE: RX (52 hex 58 hex) Select 0000 to disable Code ID for this symbology only.
SET
END
Product Reference Guide
6-53
Page 142
Symbologies
RSS Expanded, continued RSS Expanded Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever an RSS Expanded bar code is scanned.
NOTE
The options in this section set Data Group Characters for the RSS Expanded symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).
To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET RSS Expanded DATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever an RSS Expanded bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode.
1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.
6-54
QuickScan® QS6500/QS6500 BT
Page 143
RSS Expanded
RSS Expanded, continued START STATE
BARCODE
Set RSS Expanded Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET
END
Product Reference Guide
6-55
Page 144
Symbologies
RSS Limited The following options apply to the RSS Limited symbology.
Disable/Enable RSS Limited When this feature is disabled, the imager will not read RSS Limited bar codes.
Checksum Transmission Enable this option to transmit the checksum along with RSS Limited bar code data.
UCC/EAN 128 Emulation When enabled, RSS Limited bar codes will be translated to the UCC/ EAN 128 label data format.
6-56
QuickScan® QS6500/QS6500 BT
Page 145
RSS Limited
RSS Limited, continued START STATE
BARCODE
Disable RSS Limited Enable Limited Don’t Send Checksum Send Checksum Disable UCC/EAN 128 Emulation Enable UCC/EAN 128 Emulation END
Product Reference Guide
6-57
Page 146
Symbologies
RSS Limited, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.
NOTE
The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.
START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET
END
6-58
QuickScan® QS6500/QS6500 BT
Page 147
RSS Limited
RSS Limited, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted RSS Limited bar code data depending on how this feature is enabled. Example: Setting the RSS Limited Code I.D.
To configure this feature: 1. Determine which character(s) you would like to use to represent the RSS Limited symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “RL” to represent RSS Limited. The value from the table corresponding to ‘’R’ is 52 and the value for ‘L’ is 4C. These values will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET RSS Limited CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘5’ and ‘2’ (the value determined in an earlier step to represent ‘R’). Then scan the bar codes ‘4’ and ‘C’ (hex equivalent for ‘L’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE
7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned RSS Limited labels would appear as follows: Scanned bar code data:
Product Reference Guide
0123456789123
6-59
Page 148
Symbologies
Resulting message string output: RL0123456789123
RSS Limited, continued START STATE
BARCODE
Set RSS Limited Code I.D. Character(s)
DEFAULT SETTING FOR THIS FEATURE: RL (52hex, 4C hex) Select 0000 to disable Code ID for this symbology only.
SET
END
6-60
QuickScan® QS6500/QS6500 BT