The text of a manual · part 10 of 38
QuickScan QS6500/QS6500BT Product Reference Guide: Data Editing
Pages 75 to 88 of 336, from QuickScan QS6500/QS6500BT Product Reference Guide
The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS6500BT and Datalogic QS6500BT Base
Page 75
Chapter 5
Data Editing Data Editing Overview It is not recommended to use these features with IBM 46xx or IBM interfaces. CAUTION
When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.” The features in this chapter can be used to build specific user-defined data into a message string. There are several types of selectable data characters that can be sent before, after, and even between scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. Figure 5-1 shows the available elements you can add to a message string: Figure 5-1. Breakdown of a Message String Code Length Transmission: A number of data digits can be transmitted before the code data. The total length of the bar code is the number of characters of bar code data without truncated leading or ending digits.
Data Groups 1, 2, 3 and 4: Can be variably inserted into positions within the bar code data itself. One ASCII character per Data Group, with character selectable from 00 (none) to 63. Insert Groups
Prefix Symbology Preamble ID Code Length
Bar Code Data
ID Postamble Sufffix
Code ID Transmission: Enable this option to transmit the code ID. See page ?. 00 - 22 Characters (ASCII) Symbology Name: This function is used to identify and display the scanned bar code's symbology (from among any of the symbologies readable by the imager). When enabled, the code name (symbology) will be transmitted before the bar code data. 00 - 22 Characters (ASCII)
Product Reference Guide
5-1
Page 76
Data Editing
Please Keep In Mind... •
Modifying a message string is not a mandatory requirement. Data editing is sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE.
•
A prefix or suffix may be applied to one symbology (reference the Symbologies chapter for these settings) or across all symbologies (set via the features in this chapter).
•
You can add any prefix or suffix from Appendix A, ASCII Conversion Chart, plus Code I.D/AIM I.D.
•
Several entries for several symbologies can be strung together at one time.
•
Enter prefixes and suffixes in the order in which you want them to appear on the output.
Prefix/Suffix Up to 22 ASCII characters may be added as a prefix (in a position before the bar code data) and/or as a suffix (in a position following the bar code data) as indicated in Figure 5-2. Figure 5-2. Prefix and Suffix Positions
Insert Groups Prefix Symbology Preamble ID Code Length
Bar Code Data
ID Postamble Sufffix
00 - 22 Characters (ASCII)
5-2
QuickScan® QS6500/QS6500 BT
Page 77
Data Editing Overview
Prefix/Suffix, continued Example: Setting a Prefix
In this example, we’ll set a prefix for all symbologies. 1. Determine which ASCII character(s) are to be added to scanned bar code data. In this example, we’ll add a dollar sign (‘$’) as a prefix. 2. Scan the START bar code. 3. Scan the SET PREFIX CHARACTER(S) bar code. 4. Reference Appendix A, ASCII Conversion Chart, to find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is 24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from Appendix B, Alpha-Numeric Pad. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 7. The resulting message string would appear as follows: Scanned bar code data: 12345 Resulting message string output: $12345
Product Reference Guide
5-3
Page 78
Data Editing
Prefix/Suffix, continued START MODE
BARCODE Sets up to 22 characters each from the set of ASCII characters or any hex value from 0 to FF. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set Prefix” or “Set Suffix,” followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing your desired character(s). Reference the section, Example: Setting a Prefix, for more information. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None)
Set Prefix
Set Suffix
SET
END
5-4
QuickScan® QS6500/QS6500 BT
Page 79
Data Editing Overview
Preamble/Postamble Similar to the Prefix/Suffix, up to 22 ASCII characters may be added as a preamble (in a position before the bar code data) and/or as a postamble (in a position following the bar code data) as indicated in Figure 5-3. Figure 5-3. Preamble and Postamble Positions
Insert Groups Prefix Symbology Preamble ID Code Length
Bar Code Data
ID Postamble Sufffix
00 - 22 Characters (ASCII)
Example: Setting a Postamble
In this example, we’ll set a postamble for all symbologies. 1. Determine which ASCII character(s) are to be added to scanned bar code data. In this example, we’ll add the percent character (‘%’) as a postamble. 2. Scan the START bar code. 3. Scan the SET POSTAMBLE CHARACTER(S) bar code. 4. Reference Appendix A, ASCII Conversion Chart, to find the hex value assigned to the desired character. The corresponding hex number for the ‘%’ character is 25. To enter this selection code, scan the ‘2’ and ‘5’ bar codes from Appendix B, Alpha-Numeric Pad. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the TRANSMIT POSTAMBLE bar code to allow transmission of the postamble. 7. Scan the END bar code to exit Programming Mode. 8. The resulting message string would appear as follows: Scanned bar code data: 12345 Resulting message string output: 12345%
Product Reference Guide
5-5
Page 80
Data Editing
Preamble/Postamble, continued START MODE
BARCODE Sets up to 22 characters each from the set of ASCII characters or any hex value from 0 to FF. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “SET PREAMBLE” or “SET POSTAMBLE,” followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing your desired character(s). Reference the section, Example: Setting a Postamble, for more information. Accept your selection by scanning the “SET” bar code below, scan the “TRANSMIT PREAMBLE” (or “TRANSMIT POSTAMBLE” as applicable) bar code, then finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None)
Set Preamble Disable Preamble Transmit Preamble Set Postamble Disable Postamble
5-6
QuickScan® QS6500/QS6500 BT
Page 81
Data Editing Overview
START UU
MODE BARCODE
Transmit Postar PAUL e WTA END UT
Product Reference Guide 5-7
Page 82
Data Editing
Symbology, I.D. and Code Length Useful information, such as the scanned bar code’s symbology type, code I.D. and character length can all be variously added to the message string. The following are descriptions for each of these elements: Symbology, This function is used to identify and display the scanned bar code's symbology name (from among any of the symbologies readable by the imager). When enabled, the code name (symbology) will be transmitted in a position before the bar code data. Code I.D., The Code I.D. is an alpha-numeric code representing the bar code (symbology) type. It can be appended previous to and/or following the transmitted bar code data depending upon how this feature is enabled.
NOTE
An extra step is required in enabling this feature. Selection of Code I.D. Positon (either before or after bar code data) must be made PRIOR to selecting either Proprietary or AIM I.D.
In addition to message string positioning (before or after bar code data), options for this feature include: •
Disable
•
Proprietary I.D., Symbologies are identified by an associated alpha-numeric code developed by the manufacturer.
•
AIM I.D., Symbologies are identified by a standardized alphanumeric code list established by AIM (Association for Automatic Identification and Mobility).
Code Length, When enabled, this feature will calculate the total character length of the scanned bar code (minus truncated leading or ending digits) and transmit this information just previous to the actual scanned data.
5-8
QuickScan® QS6500/QS6500 BT
Page 83
Data Editing Overview Figure 5-4. Code Data Elements Code Length Transmission: A number of data digits can be transmitted before the code data. AND The total length of the bar code is the number OR of characters of bar code data without truncated leading or ending digits. Prefix Symbology Preamble ID Code Length
Bar Code Data
ID Postamble Sufffix
Code ID Transmission: Enable this option to transmit the code ID. Symbology Name: This function is used to identify and display the scanned bar code's symbology (from among any of the symbologies readable by the imager). When enabled, the code name (symbology) will be transmitted before the bar code data.
Product Reference Guide
5-9
Page 84
Data Editing
Symbology, I.D. and Code Length, continued START MODE Disable Symbology Name Enable Symbology Name Code I.D. Position: Before Bar Code Data Code I.D. Position: After Bar Code Data Code I.D. Transmission: Disable Code I.D. Transmission: Proprietary I.D. Code I.D. Transmission: AIM I.D. Disable Code Length Transmission Enable Code Length Transmission
BARCODE
END
5-10
QuickScan® QS6500/QS6500 BT
Page 85
Data Editing Overview
Data Group Characters Options are available to insert characters in up to four positions between the scanned bar code data. This is accomplished by selecting the position and up to 22 ASCII characters for each for Data Group 1, Data Group 2, Data Group 3 and Data Group 4 settings.
NOTE
The options in this chapter set Data Group Characters globally for all symbologies. If you wish to enable this feature only for a single symbology, turn to the options for that symbology in the Symbologies chapter.
Example: Setting Position and Characters for Data Group 1
In this example, we’ll set a positon and select two characters for Data Group 1. Select Data Group 1 Position
1. Determine which position in the bar code data you wish to insert character(s). In this example, we’ll select a position three characters from the left within the bar code data.
NOTE
Make sure the insertion position you select is not greater than the total number of bar code characters scanned; otherwise, the Data Group character(s) will not be inserted.
2. Scan the START bar code. 3. Scan the SET DATA GROUP 1 POSITION bar code. 4. In this step, we select the three-spaces-from-the-left position in which to place the characters we’ll select later. Scan first the 0 (zero) bar code, then the 3 bar code from the numeric digit bar codes provided in Appendix B, Alpha-Numeric Pad. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. Select Data Group 1 Character(s)
1. Determine which ASCII character(s) is/are to be added to scanned bar code data. In this example, we’ll add two characters: + (the plus sign) and # (the pound, or number sign).
Product Reference Guide
5-11
Page 86
Data Editing
2. Scan the START bar code. 3. Next, scan the SET DATA GROUP 1 CHARACTER bar code. 4. Reference Appendix A, ASCII Conversion Chart, to find the hex value assigned to each desired character. The corresponding hex number for the ‘+’ character is 2B; for the ‘#’ sign, the hex equivalent is 23. To enter the selection code, scan first the ‘2’ and ‘B’ bar codes from Appendix B, Alpha-Numeric Pad, then the ‘2’ and ‘3’ bar codes. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode. 7. Data Group Characters are configured individually for each symbology type, enabling or disabling the Data Groups you’ve created using the options provided in the Symbologies chapter. The resulting message string after completing the steps above would appear as follows: Scanned bar code data:
12345
Resulting message string output:
12+#345
Data Group Characters, continued START MODE
BARCODE Sets position and up to 22 ASCII characters each or any hex value from 0 to 64. To configure this feature, reference the section, Example: Setting Position and Characters for Data Group 1 for more information. DEFAULT SETTING FOR THIS FEATURE: 00 (None)
Set Group 1 Position Set Group 1 Character(s) Set Group 2 Position
5-12
QuickScan® QS6500/QS6500 BT
Page 87
Data Editing Overview
Data Group Characters, continued START MODE
BARCODE
Set Group 2 Character(s) Set Group 3 Position Set Group 3 Character(s) Set Group 4 Position Set Group 4 Character(s) SET END
Product Reference Guide
5-13
Page 88
Data Editing
Case Conversion This feature can convert scanned bar code data to either all lower case or all upper case characters. Case conversion affects ONLY scanned bar code data, and does not affect Code I.D., Preamble, Postamble, or other appended data. NOTE START MODE
BARCODE
Disable Convert to Upper Case Convert to Lower Case END
5-14
QuickScan® QS6500/QS6500 BT