Page 35
Chapter 3 Maintenance and Technical Specifications Introduction This chapter covers suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts).
Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. •
Do not allow any abrasive material to touch the window
•
Remove any dirt particles with a damp cloth
•
Wipe the window using a tissue moistened with ammonia/water
•
Do not spray water or other cleaning liquids directly into the window
•
Do not remove the rubber nose of the scanner.
3-1
Page 36
QuickScan QS3000/QS3500 Product Reference Guide
Troubleshooting Table 3-1. Troubleshooting Problem
Possible Causes
Nothing happens when No power to the scanner. you follow the operating instructions, or the scanner displays erratic behavior (laser does not come on, scanner emits frequent beeps). Interface/power cables are loose. Laser comes on, but Scanner is not programmed symbol does not decode. for the correct bar code type.
Symbol is decoded, but not transmitted to the host.
3-2
Possible Solutions Check the system power. Ensure the power supply is connected if your configuration requires a power supply.
Check for loose cable connections. Be sure the scanner is programmed to read the type of bar code you are scanning.
Bar code symbol is unreadable.
Check the symbol to make sure it is not defaced. Try scanning test symbols of the same bar code type.
Distance between scanner and bar code is incorrect.
Move the scanner closer to or further from the bar code.
Scanner is not programmed for the correct host type.
Scan the appropriate host type bar code.
Page 37
Maintenance and Technical Specifications
Table 3-1. Troubleshooting (Continued) Problem Scanned data is incorrectly displayed on the host.
Possible Causes
Possible Solutions
Scanner is not programmed to Be sure proper host is selected. (See the work with the host. Check host chapter for your scanner.) scanner host type parameters or editing options. For RS-232, ensure the scanner’s communication parameters match the host’s settings. For a USB HID keyboard or a keyboard wedge configuration, ensure the system is programmed for the correct keyboard type and language, and the CAPS LOCK key is in the correct state. Be sure editing options (e.g., ADF, UPCE to UPC-A Conversion) are properly programmed.
Note: If after performing these checks the symbol still does not scan, contact your distributor or call the local PSC Inc. Support Center. See page xii for the telephone numbers.
3-3
Page 38
QuickScan QS3000/QS3500 Product Reference Guide
Technical Specifications Table 3-2. Technical Specifications Item
Description
Power Requirements
QS 3000: 4.5 – 5.5 VDC @ 145 mA nominal QS3500: 4.5 – 5.5 VDC @ 145 mA nominal (decoded) 4.75 – 14.0 VDC @ 100 mA nominal (undecoded)
Stand-By Current
1 mA (max)
Power Source
Decoded: Depending on host: • Host powered • External power supply Undecoded: Power supplied by interface controller
Decode Capability
Decoded: UPC/EAN, UPC/EAN with supplementals, UCC/EAN 128, Code 39, Code 39 Full ASCII, Code 39 Trioptic, Codabar (NW7), Interleaved 2 of 5, Discrete 2 of 5, Code 128, Code 93, MSI, Code 11, UCC/EAN RSS, Code 32, Coupon Code, and Bookland EAN Undecoded: Determined by interface controller
3-4
Beeper Operation
User-selectable: Enable, Disable
Beeper Volume
User-selectable: three levels
Beeper Tone
User-selectable: three tones
Decode Depth of Field
Refer to QS3000 Decode Zone on page 2-7and QS3500 Decode Zone on page 2-8.
Scan Repetition Rate
Approximately 44 scans/sec. (bidirectional)
Skew Tolerance
± 60° min. (from normal)
Pitch Tolerance
± 65° (from normal)
Roll Tolerance
± 10° (from normal) dependent on bar code height
Page 39
Maintenance and Technical Specifications
Table 3-2. Technical Specifications (Continued) Item Print Contrast Minimum
Description 25% minimum reflectance differential, measured at 650 nm.
Ambient Light Immunity Indoor: Outdoor:
450 Ft Candles (4,842 Lux) 8,000 Ft Candles (86,112 Lux)
Durability
5 ft (1.5 m) drops to concrete
Operating Temperature
32° to 104° F (0° to 40° C)
Storage Temperature
-40° to 140° F (-40° to 60° C)
Humidity
5% to 95% (non-condensing)
Weight (without cable)
4.2 oz. (120 g)
Dimensions: Height Width Depth
5.3 in. (13.5 cm) 2.5 in. (6.4 cm) 2.2 in. (5.6 cm)
Laser
650nm laser diode
Laser Classifications
CDRH Class 2 (QS3500) IEC 825-1 Class 1 (QS3000)
ESD
15 kV air discharge 8 kV contact discharge
Minimum Element Width
5 mil (0.127 mm)
Interfaces Supported
Decoded: RS-232, Keyboard Wedge, Wand Emulation, IBM 468X/469X, USB, Synapse Undecoded: Undecoded (Decoding is based on interface controller)
3-5
Page 40
QuickScan QS3000/QS3500 Product Reference Guide
Scanner Signal Descriptions
Bottom of scanner
Cable interface port
PIN 10
PIN 1
Interface cable modular connector
Figure 3-1. Scanner Cable Pinouts
3-6
Page 41
Maintenance and Technical Specifications
The signal descriptions in Table 3-3 apply to the connector on the scanner and are for reference only.
Table 3-3. Scanner Signal Pin-outs QS3000 Pin
QS3500 IBM
Synapse
RS-232
Keyboard Wedge
Wand
USB
1
Reserved
Reserved
SynClock
Reserved
Reserved
Reserved Jump to Pin 6
2
Power
Power
Power
Power
Power
Power
Power
3
Ground
Ground
Ground
Ground
Ground
Ground
Ground
4
Enable
IBM_A(+)
Reserved
TxD
KeyClock
Bar Data
Reserved
5
SOS
Reserved
Reserved
RxD
TermData
CTS
D+
6
Trigger*
IBM_B(-)
SynData
RTS
KeyData
RTS
Jump to Pin 1
7
Good Read Reserved
Reserved
CTS
TermClock
Reserved D -
8
Bar Data
Reserved
Reserved
Reserved
Reserved
Reserved Reserved
9
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved Reserved
10
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved Reserved
3-7
Page 42
NO yA | |_! QuickScan QS3000/QS3500 Product Reference Guide
3-8