The text of a manual · part 24 of 40
QuickScan 3000 & 3500 Handheld Bar Code Scanner Product Reference Guide, pages 209 to 216
Pages 209 to 216 of 352
The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS-3000, Datalogic QS-3000 and PSC QS-3500
Page 209
Symbologies
Transmit MSI Check Digit(s) Scan a bar code below to transmit MSI data with or without the check digit.
Transmit MSI Check Digit(s) (Enable)
*Do Not Transmit MSI Check Digit(s) (Disable)
11-69
Page 210
QuickScan QS3000/QS3500 Product Reference Guide
MSI Check Digit Algorithm Two algorithms are possible for the verification of the second MSI check digit. Select the bar code below corresponding to the algorithm used to encode your check digit.
MOD 10/MOD 11
*MOD 10/MOD 10
11-70
Page 211
Symbologies
RSS (Reduced Space Symbology) RSS 14 The variants of RSS are RSS 14, RSS Expanded, and RSS Limited. The limited and expanded versions have stacked variants. Scan the appropriate bar code below to enable or disable each variant of RSS.
Enable RSS 14
*Disable RSS 14
11-71
Page 212
QuickScan QS3000/QS3500 Product Reference Guide
RSS Limited
Enable RSS Limited
*Disable RSS Limited RSS Expanded
Enable RSS Expanded
*Disable RSS Expanded
11-72
Page 213
Symbologies
Symbology - Specific Security Levels Linear Code Type Security Level In most environments and applications the default setting provides an adequate level of security. However, some environments or applications may require an increased reading of security such as poorly printed bar codes, use of weak symbologies, or mission critical applications. As the security level increases, the scanner decode speed may decrease. Select the security level appropriate for your environment or application. Note: These security levels do not apply to UPC/EAN and RSS.
Linear Security Level 1 Level 1 affects only Codabar, MSI, D2 of 5 and I 2 of 5. The codes listed in Table 11-3 below will be successfully read twice before reporting a good decode. Table 11-3. Linear Security Level 1 Code Types Code Type
Length
Codabar
All
MSI
4 or less
D 2 of 5
8 or less
I 2 of 5
8 or less
*Linear Security Level 1
11-73
Page 214
QuickScan QS3000/QS3500 Product Reference Guide
Linear Security Level 2 Level 2 ensures that the enabled linear bar code types are read twice before reporting a good decode.
Linear Security Level 2
Linear Security Level 3 Level 3 ensures that the enabled linear bar code types are read twice before reporting a good decode. If scanning the codes in Table 11-4 below, level 3 ensures that the codes are read three times before reporting a good decode. Table 11-4. Linear Security Level 3 Code Types Code Type
Length
MSI
4 or less
D 2 of 5
8 or less
I 2 of 5
8 or less
Codabar
8 or less
Linear Security Level 3
11-74
Page 215
Symbologies
Linear Security Level 4 Level 4 ensures that all enabled linear bar code types are read three times before reporting a good decode.
Linear Security Level 4
11-75
Page 216
QuickScan QS3000/QS3500 Product Reference Guide
Bi-directional Redundancy Bi-Directional Redundancy is used for added security to linear code type security levels. When enabled, a bar code must be successfully scanned in both directions (forward and reverse) before reporting a good decode.
Enable Bi-directional Redundancy
*Disable Bi-directional Redundancy
11-76