QuickScan 3000 & 3500 Handheld Bar Code Scanner Product Reference Guide, pages 139 to 148

Pages 139 to 148 of 352: Chapter 10 Configurator ExpressTM; Chapter 11 Symbologies

The original document is the PDF (4.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC QS-3000, Datalogic QS-3000 and PSC QS-3500

Page 139

Chapter 10 Configurator ExpressTM Introduction This chapter includes the bar code you must scan to use the Configurator Express program. Configurator Express is a Windows® based utility that allows the scanner to be setup and programmed with all parameters including Advanced Data Formatting (ADF) rules. An ADF rule allows bar code data to be modified before it is sent on to the host. This ensures compatibility between bar coded data and the host application; the scanner is programmed rather than modifying the host software. Scanners can be programmed via PC download or by scanning a sheet of bar codes generated by the utility. Scanner programming is saved in a file that can be distributed electronically by e-mail. A help file is built into the Configurator Express program.

Communication With the Configurator Express PC Based Configuration Tool In order to communicate with the Configurator Express program, which runs on a PC with Windows, use an RS-232 cable to connect the scanner to the PC (see Connecting an RS232 Interface on page 6-2). You will need: •

PC with Windows

•

Scanner

•

RS-232 cable 10-1

Page 140

QuickScan QS3000/QS3500 Product Reference Guide

Configurator Express Parameter In order to communicate with the Configurator Express program, load Configurator Express onto your PC and scan the bar code below. Refer to Configurator Express instructions for programming your scanner. Note: Scanning this bar code enables the Configurator Express interface on the scanner.

³ Configurator S X S A C 1Express 0 1 0 Enable 1 0 1 6

10-2

Page 141

Chapter 11 Symbologies Introduction This chapter describes all symbology features and provides the programming bar codes necessary for selecting these features for your QS3x00 scanner. Before programming, follow the instructions in Chapter 1, Getting Started. Note: To program the undecoded QS3500 scanner, refer to the programming guide for your external interface controller or portable terminal. Your scanner is shipped with the settings shown in the Symbology Default Table on page 11-3 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous scanner defaults). If the default values suit your requirements, programming may not be necessary. Features values are set by scanning single bar codes or short bar code sequences. To return all features to their default values, all you need to do is scan the Set All Defaults bar code on page 4-4. If you are not using a Synapse or USB cable you must select a host type. Refer to each host chapter for specific host information.

11-1

Page 142

QuickScan QS3000/QS3500 Product Reference Guide

Scanning Sequence Examples In most cases you need only scan one bar code to set a specific parameter value. For example, if you want to transmit bar code data without the UPC-A check digit, simply scan the Do Not Transmit UPC-A Check Digit bar code listed under Transmit UPC-A/UPC-E/UPCE1 Check Digit on page 11-14. The scanner issues a short high beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5 require that you scan several bar codes in the proper sequence. Refer to the individual parameter, like Set Length(s) for D 2 of 5, for this procedure.

Errors While Scanning Unless otherwise specified, if you make an error during a scanning sequence, just re-scan the correct parameter.

11-2

Page 143

Symbologies

Symbology Default Parameters Table 11-1 lists the defaults for all symbologies parameters. If you wish to change any option, scan the appropriate bar code(s) provided in the Symbologies Parameters section beginning on 11-7. Note: See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.

Table 11-1. Symbology Default Table Parameter

Default

Page Number

UPC/EAN UPC-A

Enable

11-7

UPC-E

Enable

11-7

UPC-E1

Disable

11-8

EAN-13

Enable

11-9

EAN-8

Enable

11-9

Bookland EAN

Disable

11-10

Decode UPC/EAN Supplementals (2 and 5 digits)

Ignore

11-11

Decode UPC/EAN Supplemental Redundancy

7

11-13

Transmit UPC-A Check Digit

Enable

11-14

Transmit UPC-E Check Digit

Enable

11-14

Transmit UPC-E1 Check Digit

Enable

11-15

UPC-A Preamble

System Character

11-16

11-3

Page 144

QuickScan QS3000/QS3500 Product Reference Guide

Table 11-1. Symbology Default Table (Continued) Parameter

Default

Page Number

UPC-E Preamble

System Character

11-17

UPC-E1 Preamble

System Character

11-18

Convert UPC-E to A

Disable

11-19

Convert UPC-E1 to A

Disable

11-20

EAN-8 Zero Extend

Disable

11-21

UPC/EAN Security Levels

0

11-22

UCC Coupon Extended Code

Disable

11-24

Code 128

Enable

11-25

UCC/EAN-128

Enable

11-26

ISBT 128 (non-concatenated)

Enable

11-27

Code 39

Enable

11-28

Trioptic Code 39

Disable

11-29

Convert Code 39 to Code 32 (Italian Pharma Code)

Disable

11-30

Code 32 Prefix

Disable

11-31

Set Length(s) for Code 39

2 to 55

11-32

Code 39 Check Digit Verification

Disable

11-34

Transmit Code 39 Check Digit

Disable

11-35

Code 39 Full ASCII Conversion

Disable

11-36

Code 128

Code 39

11-4

Page 145

Symbologies

Table 11-1. Symbology Default Table (Continued) Parameter Code 39 Buffering (Scan & Store)

Default

Page Number

Disable

11-39

Code 93

Disable

11-43

Set Length(s) for Code 93

4 to 55

11-44

Code 11

Disable

11-46

Set Lengths for Code 11

4 to 55

11-47

Code 11 Check Digit Verification

Disable

11-49

Transmit Code 11 Check Digit

Disable

11-50

Interleaved 2 of 5 (ITF)

Enable

11-51

Set Length(s) for I 2 of 5

14

11-52

I 2 of 5 Check Digit Verification

Disable

11-54

Transmit I 2 of 5 Check Digit

Disable

11-55

Convert I 2 of 5 to EAN 13

Disable

11-56

Discrete 2 of 5

Disable

11-57

Set Length(s) for D 2 of 5

12

11-58

Disable

11-60

Code 93

Code 11

Interleaved 2 of 5 (ITF)

Discrete 2 of 5 (DTF)

Codabar (NW - 7) Codabar

11-5

Page 146

QuickScan QS3000/QS3500 Product Reference Guide

Table 11-1. Symbology Default Table (Continued) Parameter

Default

Page Number

Set Lengths for Codabar

5 to 55

11-62

CLSI Editing

Disable

11-63

NOTIS Editing

Disable

11-64

MSI

Disable

11-65

Set Length(s) for MSI

1 to 55

11-67

MSI Check Digits

One MSI Check Digit

11-68

Transmit MSI Check Digit(s)

Disable

11-69

MSI Check Digit Algorithm

Mod 10/Mod 10

11-70

RSS 14

Disable

11-71

RSS Limited

Disable

11-72

RSS Expanded

Disable

11-72

Linear Code Type Security Levels

Linear Security Level 1

11-73

Bi-directional Redundancy

Disable

11-76

MSI

RSS (Reduced Space Symbology)

Symbology - Specific Security Levels

11-6

Page 147

Symbologies

UPC/EAN Enable/Disable UPC-A/UPC-E To enable or disable UPC-A or UPC-E, scan the appropriate bar code below.

*Enable UPC-A

Disable UPC-A

*Enable UPC-E

Disable UPC-E

11-7

Page 148

QuickScan QS3000/QS3500 Product Reference Guide

Enable/Disable UPC-E1 UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. Note: UPC-E1 is not a UCC (Uniform Code Council) approved symbology.

Enable UPC-E1

*Disable UPC-E1

11-8