The text of a manual · part 6 of 13
Falcon PT40 Product Reference Guide, pages 51 to 60
Pages 51 to 60 of 122
The original document is the PDF (6.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC PT40 and Datalogic PT40
Page 51
2340.book Page 27 Wednesday, January 29, 2003 12:50 PM
Reviewing the Collected Data
2. If the displayed date is correct, press the <ENTER> key. If the date is wrong, enter the correct date. Use two digits each for the month, for the day, and for the year (e.g. 101602). The program will automatically format the entry (e.g. 10/16/02). Current Date: 10/16/02 Enter New Date: ¤
3. If the displayed time is correct, press the <ENT> key. If the time is wrong, enter the correct time in 24-hour format. Use two digits each for the hour, minute, and seconds (e.g., 211732). Current Time: 21:17:32 Enter New Time: ¤
Reviewing the Collected Data Before uploading collected data, review it on the PT40 and delete incorrect or unnecessary records. 1. From any screen that offers REV as an option, select <F3> to display the data-review screen (shown in Figure 2-14 on page 2-28). ITEM ID ¤ F3=REV F4=EXIT
• The last data that was input is displayed on the third line of the screen. • If the record includes a quantity, the quantity is given after a comma at the end of the line.
Product Reference Guide
2-27
Page 52
2340.book Page 28 Wednesday, January 29, 2003 12:50 PM
Data Collection with PT40 Software Applications
• The second line of the data-review screen tells the number of the currently displayed record and the total number of records. The top line of the data-review screen offers options for moving through the records in memory. Figure 2-14. Data Review Displays
F1=PREV F2=NEXT REC#65 OF 65¤ R44-2342 F3=DEL F4=EXIT¤
F1=PREV F2=NEXT REC#65 OF 65¤ R44-2342, 15 F3=DEL F4=EXIT¤
Item-only data
Item-and-quantity data
2. Press the <F2> key to move to the next record. • If the currently displayed record is the last one, the PT40 will briefly display END OF FILE on the second line. 3. Press the <F1> key to move to the previous record. • If the currently displayed record is the first one, the PT40 will briefly display START OF FILE on the second line. 4. The 4th line of the screen offers options for deleting records and returning to the data-collection screen. • To delete the currently displayed record, press the <F3> key. The message ARE YOU SURE? appears on the first line of the screen. • To delete the record, press <F3> again; to cancel, press <F4>. 5. When finished reviewing the data records, press <F4> once to return to the data-collection screen or twice to return to the application menu.
2-28
Falcon® PT40
Page 53
2340.book Page 1 Wednesday, January 29, 2003 12:50 PM
Chapter 3 Transferring Files and Data Overview When you are finished inputting data by scanning bar codes or collecting data in a file, transmit (upload) the files from the PT40 to the host PC using XFER32. XFER32 is a data transfer application that is included on the CD that came with your Falcon PT40. Refer to Using XFER32 on page 3-2. XFER32 runs on Microsoft Windows versions ‘98, 2000, Me, NT, and XP.
Utilities are available on the CD that cam e with your PT40 and updates are free from PSC’s website. Click on the Support link at www.pscnet.com to download the most current file transfer program. You can also download PDTFER from PSC’s website if you use a DOS Host PC. PDTFER is a DOS file transfer program that runs on a DOS Host PC by issuing commands on the DOS command line. Refer to PT40 Dock, Serial Cable, and Power Adaptor on page B-1 for detailed information on how to connect the PT40 to a PC. Use only the Falcon PT40 Dock or PT40 serial cable for data transfer. The use of another dock or serial cable could void your warranty. For a list of PT40 accessories and part numbers, refer to PSC’s Price Book at: http: www.pscnet.com.
The following topics are covered in this section of this manual: •
Uploading Data to the Host PC starting on page 3-2.
•
Using XFER32 starting on page 3-2.
• XFER32 Setup starting on page 3-3. • Sending and Receiving Data with XFER32 starting on page 3-6 •
Downloading Applications with PPGXFER starting on page 3-8
•
Removing Collected Data from Memory starting on page 3-13.
Product Reference Guide
3-1
Page 54
2340.book Page 2 Wednesday, January 29, 2003 12:50 PM
Transferring Files and Data
Uploading Data to the Host PC To upload data to the Host PC from the PT40, complete the following steps: 1. Prepare the Host PC to receive the collected data. 2. Prepare the Falcon PT40 to upload (transmit) the collected data. From the program menu on the PT40; select <F3> to display the File Options menu. INV MGMT¤ F2=COLLECT F3=FILE OPTIONS F4=EXIT
3. Select <F2> to display the Send File menu. *FILE OPTIONS* F2=SEND FILE F3=ERASE FILE F4=EXIT¤
4. Select <F2> to upload the data via the serial connection. *SEND FILE* F2=SERIAL F4=EXIT ¤
Using XFER32 XFER32 is a communications application used to transfer data between the Falcon PT40 and a Host PC A copy of XFER32 was included on the CD that came with your Falcon PT40 and is installed with the PT40 applications automatically.
3-2
Falcon® PT40
Page 55
2340.book Page 3 Wednesday, January 29, 2003 12:50 PM
Using XFER32
XFER32 Setup When you start XFER32, the user interface, shown in Figure 3-1, opens. Figure 3-1. XFER32 User Interface
To prepare for data transfer between the PC and the PT40, click on the Setup button to open the Setup dialog box, which contains three tabbed sections: • General Tab on page 3-3. • Transfer Tab on page 3-5. • Logging Tab on page 3-6. The settings in these dialogs can be modified or customized to meet your communications requirements.
General Tab The General tab is the first tab displayed on the XFER32 Setup dialog box. Modify the PT40’s Connection, Baud Rate, Flow Control, Protocol (ACK/ NAK and XModem are the only protocols supported by the PT40) on this tab. Figure 3-2. General Tab
Product Reference Guide
3-3
Page 56
2340.book Page 4 Wednesday, January 29, 2003 12:50 PM
Transferring Files and Data
Connection
Enter the Connection port for file transfers. Select from the list of detected serial ports or modems.
Baud Rate
Select a Baud Rate for serial communications from the pull-down list. The default value for XFER32 is 19200. The default value for the PT40 is 9600. Note: The PT40 supports only baud rates up to 38400.
Protocol
Select either XModem or ACK/NAK as the file transfer Protocol for sending and receiving files. NOTE: ZModem Protocol is NOT supported by the Falcon PT40. NOTE: The PT40 defaults to the ACK/NAK protocol unless you select XModem. XFER32 defaults to the ZModem Protocol. ACK/NAK and XModem Protocol are the only two protocols supported by the PT40.
Maximum Errors Enter the maximum number of Errors permitted before a file transfer is aborted. Range: 1 to 50. 0 specifies no limit to the number of file transfer errors. Flow Control
Select the mechanism used to control the flow of data. Sender and receiver must agree on the flow control method.
Note: RTS/CTS is the default. Use either None or RTS/CTS. XON/XOFF is not supported by the PT40. None
No flow control used.
XON/XOFF
NOTE: ZModem Protocol is NOT supported by the Falcon PT40. This feature is only available with ZModem protocol.
RTS/CTS
Hardware flow control that uses Request to Send (RTS), and Clear to Send (CTS) serial port lines to communicate when to suspend and resume data transfer.
Window Size
3-4
NOTE: ZModem Protocol is NOT supported by the Falcon PT40. This feature is only available with ZModem protocol. Falcon® PT40
Page 57
2340.book Page 5 Wednesday, January 29, 2003 12:50 PM
Using XFER32
Crash Recovery NOTE: ZModem Protocol is NOT supported by the Falcon PT40. This feature is only available with ZModem protocol.
Transfer Tab Select the Transfer tab to establish file transfer settings. Figure 3-3. Transfer Tab of the File Transfer Utility
Sender Timeout (Seconds)
Enter the maximum number of seconds to wait for a connection when sending files. A value of 0 waits indefinitely.
Receiver Timeout
Enter the maximum number of seconds to wait for a connection when receiving files. A value of 0 waits indefinitely.
Path/Filename Transmission
NOTE: ZModem Protocol is NOT supported by the Falcon PT40. This feature is only available with ZModem protocol.
Overwrite
Select to determine the action the receiver takes when a received file already exists.
Source Longer or Overwrites the existing file if the received file is longer or Newer newer. CRCs Don’t Match
Overwrites the existing file if the CRCs of both files don’t match.
Append
Appends the received file to the existing one.
Always
Overwrites the existing file with the one received.
Source Newer
Overwrites the existing file if the received file is newer.
Date/Length Don’t Match
Overwrites the existing file if the dates or lengths of both files don’t match.
Never
Skips the transfer if the received file already exists.
Product Reference Guide
3-5
Page 58
2340.book Page 6 Wednesday, January 29, 2003 12:50 PM
Transferring Files and Data
File Transfer Default
Enter the File Transfer Default folder for storing received files. Use the Browse button to locate a new location.
Logging Tab Select the Logging tab to establish settings for the communications log. The communications log can be helpful as a trouble-shooting aid. Figure 3-4. Logging Tab of the File Transfer Utility
Log To File
Specifies that the log is to be written to a text file.
Log To Screen
Specifies that the log is displayed on screen.
Append to Log
This option becomes available when you select Log to File. When enabled, Append to Log adds log information to the end of the log file. If not enabled, new log information replaces the previous log file.
Log Path/ Filename
Specify the location for storing the communications log. If a path is not given, the file is stored in the Default File Transfer folder.
Browse
Use the Browse button to locate a new log file.
Sending and Receiving Data with XFER32 Verify that the PT40 is properly attached to the host PC. If you have a PT40 dock for your PT40, make sure that the dock is properly attached to the PC. Refer to Transmit Files, below for specifics on sending files. Refer to Receive Files on page 3-7 for specifics on receiving files
3-6
Falcon® PT40
Page 59
2340.book Page 7 Wednesday, January 29, 2003 12:50 PM
Using XFER32
Transmit Files 1. To transmit files from the Host PC to the PT40, select the Transmit Files button from the XFER32 user interface. Figure 3-1 on page 3 illustrates the user interface. Figure 3-5. Send File to PT40 Window
2. Select the file to send. 3. Click Open to send the file to the data collection terminal
Receive Files When receiving files from a data collection terminal, a prompt appears. Enter the name of the incoming file. 1. To receive files from the Host PC to the PT40, select the Receive Files button from the XFER32 user interface. Figure 3-1 on page 3 illustrates the user interface. 2. Select (or enter) a filename for the file.
Product Reference Guide
3-7
Page 60
2340.book Page 8 Wednesday, January 29, 2003 12:50 PM
Transferring Files and Data
Figure 3-6. Receive File from PT40 Window
3. Click Open to begin receiving the file.
Downloading Applications with PPGXFER The Falcon PT40 comes with a collection of applications and utilities. This collection is called the PALPRO40. Use PPGXFER to download programs to the PT40 from your Windows compatible PC. A copy of PPGXFER is included on the CD that came with your Falcon PT40 and is installed automatically when you install PPG. The windows shown for PPGXFER were captured on a PC running Microsoft Windows® 2000. If your PC uses another version of Windows, PPGXFER windows may appear slightly different. PPGXFER checks the version number of the PT40's operating system. If it is different from the PALPRO40 version, it installs the operating system along with the application. During the application download process, a number of steps take place.
1. The downloader checks the version number of the portable’s operating system. 2. If the portable’s operating system is out-dated, the downloader allows you to choose from three different options.
3-8
Falcon® PT40