The text of a manual · part 2 of 13
Falcon PT40 Product Reference Guide, pages 11 to 20
Pages 11 to 20 of 122
The original document is the PDF (6.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC PT40 and Datalogic PT40
Page 11
2340.book Page 1 Wednesday, January 29, 2003 12:50 PM
Chapter 1 Introduction Overview of the PSC Falcon PT40 The Falcon PT40 is a rugged, handheld, portable data-collection terminal that allows bar code scanning technology anywhere. The PT40 automatically recognizes and discriminates among the following bar code symbologies when using the laser scanner: Codabar
EAN-8
Interleaved 2 of 5
Code 39
EAN-13
UPC-A
Code 93
JAN-8
UPC-E
Code 128
JAN-13
UPC/EAN/JAN extensions
The PT40 verifies input by sounding a beep. The beeper’s tone, volume, pitch, and duration can be changed to suit your work environment and personal preferences. The PT40’s liquid crystal display (LCD) is easy to read and can be backlit for poorly lit work environments. Use the keypad to input numbers and letters, change input modes, and navigate the display and application menus. This introduction covers the basic functions of the PT40 operation, including turning the PT40 on and off, using action keys, inputting data and alphanumeric key use, navigating the display screen, scanning bar codes, an overview of PT40 applications, and accessories. •
PT40 Power Button and Reset starting on page 1-2.
•
The Keypad starting on page 1-3.
•
The Display Screen starting on page 1-6.
•
The PT40 Laser starting on page 1-8.
•
The Beeper on page 1-9.
•
PT40 Software Applications starting on page 1-9.
•
Accessories starting on page 1-12.
Product Reference Guide
1-1
Page 12
2340.book Page 2 Wednesday, January 29, 2003 12:50 PM
Introduction
PT40 Power Button and Reset Turning the PT40 On Press the green <PWR> key displayed at left to turn the PT40 on. The first screen that appears on the PT40, unless the software has been customized, is shown below. -Falcon PT40zVer 020.5/Z0.2 System RAM 256K 10/16/02 14:09 ¤ press any key If the unit had been running before it was turned off, the display screen returns to the view displayed when the unit was turned off.
Auto-Off Timeout The PT40 is programmed to shut itself off automatically if it is not used for ten (10) minutes. This Auto-Off timeout conserves power in the PT 40 by partially shutting down when it is not in use. Press the <PWR> key to return the PT40 to full power. The following Auto-Off timeout values can be customized: Auto-Off Timeout
Values
Value range
1 - 99 minutes
Default value
10 minutes
Disable value
00
Refer to Auto-Off on page E-11 for more information on customizing this feature.
Turning the PT40 Off Turn the PT40 off by pressing the <PWR> key displayed at left. This turns the screen display off, but does not clear any information in the PDT’s randomaccess memory (RAM). The PT40 will return to this location when it is turned on again. There is no beep when the <PWR> key is pressed to turn the PT40 off.
1-2
Falcon® PT40
Page 13
2340.book Page 3 Wednesday, January 29, 2003 12:50 PM
The Keypad
Resetting the PT40 Sometimes you will need to reset the PT40. Both Soft Reset and Hard Reset return the PT40 to the opening display screen (refer to Figure 1-1 on page 1-2) and return a unique series of beeps and tones to verify the reset. Resetting the PT40 is similar to pressing <Ctrl>+<Alt>+<Delete> on a PC. All data stored in the portable’s memory is cleared. CAUTION Soft Reset: Use a soft reset to reboot a PT40 when there is power available. Scan the following reset bar code: Reset *
+
.
*
Hard Reset: Use a hard reset to reboot a PT40 without power.
1. Remove the main battery or external power supply. 2. Press and hold the <CLR> and <ENT> keys while reinserting the main battery or reconnecting the power supply.
The Keypad The keypad on the PT40 has three types of keys: action keys, function keys, and data keys. Each key produces a beep when pressed. •
Refer to Figure 1-2 on page 1-4 for an illustration of the Falcon PT40.
•
Refer to Table 1-1 on page 1-5 for a list of data keys and cycles.
•
Refer to Table 1-2 on page 1-5 for a list of action keys and functions.
Product Reference Guide
1-3
Page 14
2340.book Page 4 Wednesday, January 29, 2003 12:50 PM
Introduction
Figure 1-1. Falcon PT40 Keypad
Function Keys Enter Key
Clear Key Scan Key
Data Keys
Navigation Keys Shift Key
Backlight Key
Power Key
Data Keys Use the twelve (12) data keys to enter letters, numbers, and other characters. If you enter an incorrect number or character, press the <CLR> key to move the cursor back one position. Press and hold the <CLR> key to clear an entire line. Normal Mode. By default, data keys yield numbers. Shift Mode. To input letters, press the <SH> key to enter Shift mode. The
Shift mode cursor is displayed with reverse video. The PT40 remains in Shift mode until you press <SH> again. Press the data key once, twice, or more times to cycle through the letters until the desired letter appears on the display. After the last letter in the sequence for that key, the next keypress yields the number. Another keypress starts the letter sequence again. Letters are only available in upper case.
1-4
Falcon® PT40
Page 15
2340.book Page 5 Wednesday, January 29, 2003 12:50 PM
The Keypad
Table 1-1. Inputting Characters Using Data Keys Normal Mode
Shift Mode
Number/Symbol
First Keypress
Second Keypress
Third Keypress
Fourth Keypress
Fifth Keypress
0 space
0 space
0 space
1
1
1
1
1
1
2
A
B
C
2
A
3
D
E
F
3
D
4
G
H
I
4
G
5
J
K
L
5
J
6
M
N
O
6
M
7
P
Q
R
S
7
8
T
U
V
8
T
9
W
X
W
Z
9
* (Asterisk)
In both Normal and Shift mode, press the * key to insert an asterisk.
. (Decimal/ Period)
In both Normal and Shift modes, press the Decimal/Period key to insert a decimal or period into a number sequence or character string.
There is a default one (1) second time-delay before the cursor moves to the next position. This duration value can be customized. Use the <RIGHT> arrow navigation key to move one position right before delay expires.
Function Keys There are four function keys, <F1> through <F4>, at the top of the keypad. Press the <SH> key to enter Shift mode and access function keys <F5> through <F8>. The actions for function keys are determined by the active program.
Product Reference Guide
1-5
Page 16
2340.book Page 6 Wednesday, January 29, 2003 12:50 PM
Introduction
Action Keys Ten action keys, including the four navigation keys, are described in Table 1-1. Table 1-2. Falcon PT40 Action Keys Button
1-6
Function /Mode
Description
Referred to As
Clear
Press <CLR> to move the cursor back one position. Press and hold <CLR> to clear an entire line of text.
<CLR>
Scan
Aim the PT40 at a bar code and press the <SCAN> key to activate laser scanning mode.
<SCAN>
Enter
Press the <ENT> key to enter the current data string and move to the next command.
<ENT>
Up Arrow
Press the <UP> arrow to move the actual display up one line in the virtual display.
<UP>
Down Arrow
Press the <DOWN> arrow to move the actual display down one line in the virtual display.
<DOWN>
Left Arrow
Press the <LEFT> arrow to move the actual display to the left 4 characters in the virtual display. I
<LEFT>
Right Arrow
Press the <RIGHT> arrow to move the actual display to the right 4 characters in the virtual display. In Shift mode, the <RIGHT> arrow key acts as an insert key to override the time delay.
<RIGHT>
Shift Mode
Press the <SH> key to enter Shift mode. Use Shift mode to access alpha characters or toggle the function keys between <F1>-<F4> and <F5>-<F8>.
<SH>
Power
Press the <PWR> key to turn the PT40 on and off. When the PT40 is turned on, it beeps and returns to the location at last shut off.
<PWR>
Press the <BL> key to turn the LCD backlight on or Backlight off. The default timeout on the backlight is 30 secOn/Off onds. The duration value can be customized.
<BL>
Falcon® PT40
Page 17
2340.book Page 7 Wednesday, January 29, 2003 12:50 PM
The Display Screen
The Display Screen The default system font for the PT40 is a 5x7 (width x height in pixels) font based on the Codepage 850 Western European character set. This size font allows the PT40's LCD display screen to show 6 lines of text with up to 16 characters on each line when using only the default system font.
Actual vs. Virtual Display The Falcon PT40's actual display screen is a window to a larger display area called the virtual display (refer to Figure 1-3). Most applications you will use will fit into the actual display. However, applications can sometimes contain data longer than the default 6 line x 16 character view of the actual display. Figure 1-2. Virtual vs. Actual Display Using Default System Font
0,0 Actual Display
16 characters wide 80 characters wide The shaded box F1=NEXT F2=PRE represents the PT40 REC#11 OF 16 display screen. 6 lines high 120850A30NME5274J400967629
25 lines high
F3=REV F4=EXIT F1=NEXT F2=PRE REC#12 OF 16 120850A30NME5274J400984019 F3=REV F4=EXIT F1=NEXT F2=PRE REC#13 OF 16 120850A30NME5274J400942885 F3=REV F4=EXIT
Virtual Display: The larger area represents the maximum size for the Virtual Display in some applications (visible to the user only by using the arrow navigation keys)
Adding or changing character sizes will change the appearance of the actual display. The number of lines and characters will vary with the character sizes.
The actual display screen shows only a portion of the available data in the virtual display. Use the arrow keys to navigate the actual display screen to view Product Reference Guide
1-7
Page 18
2340.book Page 8 Wednesday, January 29, 2003 12:50 PM
Introduction the virtual display data. The text in the virtual display remains in place and the actual display screen changes its view within the virtual display. If you scan longer bar codes or enter more data than can fit in a single line of the virtual display, the data automatically wraps to the next line. Because applications for the PT40 can contain and use different fonts, the amount of data that is available within the virtual display will vary. The virtual display maintains the latest lines of data once all lines of the virtual display are full. The oldest lines of data are “pushed off the top” as new data is added at the bottom.
Contrast To adjust the screen contrast while the PT40 is running an application, press the <SH> key to enter Shift Mode. Use the Up or Down arrow keys to increase or decrease the screen contrast.
Backlight The PT40’s liquid crystal display (LCD) is easy to read in all lighting situations using the backlight feature. Press the <BL> key to turn the backlight on or off.
Displaying Information about the PT40 Display information about the PT40 by scrolling the actual display past the last character on a current line. Press the <Right> arrow key until the version number and current application name are displayed. The actual display lists the system version number and the amount of random-access memory installed (refer to Figure 1-1 on page 1-2).
The PT40 Laser The PT40 laser is an integral part of the Falcon PT40. Use the PT40 to scan bar code labels on flat, curved, or irregular surfaces at distances ranging from one inch to 18 inches. The actual scan distance depends upon the symbology, density, and the lighting conditions.
1-8
Falcon® PT40
Page 19
2340.book Page 9 Wednesday, January 29, 2003 12:50 PM
The Beeper
Scanning Bar Codes with the PT40 Aim and press the <SCAN> key. Figure 1-4 illustrates the correct orientation for best scanning results. •
The laser should be pointed at a slight angle to the bar code. Do not orient the PT40’s laser parallel or perpendicular to the bar code.
•
The laser beam must cross the entire bar code. The PT40 cannot correctly read if the entire bar code is not scanned.
Figure 1-3. How to Scan
Verifying Operation A red LED (light-emitting diode) on the top right indicates laser activation and good reads. The PT40 verifies that it accepts the scanned input by sounding an audible tone.
The Beeper The PT40 provides audible feedback to indicate when a bar code has been scanned successfully and to acknowledge when a key has been pressed. The default setting provides one beep to indicate a good scan or key entry. Another beep sequence warns of possible problems. The tone, pitch, volume, number, and length of beeps can all be modified. Refer to Configuring with Bar Codes starting on page D-1 for more information on customizing your Falcon PT40.
Product Reference Guide
1-9
Page 20
2340.book Page 10 Wednesday, January 29, 2003 12:50 PM
Introduction
PT40 Software Applications The Falcon PT40 comes from the factory with PSC’s PALPRO40 application and three other data collection applications already installed. If your PT40 software has been customized, it may operate differently. Check with your systems administrator for instructions.
PALPRO40 PALPRO40 is part of the PSC Portable Applications Library (PAL). With PAL, you can customize the PT40 without programming. PALPRO40 consists of three programs, which coexist in memory: ASSETPRO Use ASSETPRO for tracking assets at various locations. INVPRO
Use INVPRO for inventory control. Customize it to collect item-and-quantity information or item-only data.
TRACKPRO Use TRACKPRO for tracking check-in and check-out of articles at one or more locations. An optional date-and-time stamp records when each item is checked in or out.
A password is required when all three PALPRO40 applications are loaded at the same time.
Data Collection Applications In addition to PALPRO40, the PT40 also comes with the following basic data collection applications loaded in memory: DESCRIPT
DESCRIPT is a description application.
INVMODEM INVMODEM is an inventory application with a modem option. TIMESTMP
TIMESTMP is an item-tracking application that records the date and time data was entered.
No password is required for these applications.
PT Program Generator (PPG) PT Program Generator™ v5.0 (PPG™) is an application designed to work with the Falcon PT40 to create custom applications that collect, verify, and
1-10
Falcon® PT40