Page 178

2342.book Page 166 Thursday, July 22, 2004 8:35 AM

PPG System Commands

Reset Mode CAUTION

166

Clears all memory and resets the portable. *

+

.

*

PT Program Generator (PPG) v5.0

Page 179

2342.book Page 167 Thursday, July 22, 2004 8:35 AM

Appendix E: ASCII/Hex Conversion Table ASCII NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

User’s Guide

Hex 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

ASCII SP ! “ # $ % & & ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

Hex 20 21 22 23 24 25 26 26 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F

ASCII @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _

Hex 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F

ASCII a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL

Hex 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F

167

Page 180

2342.book Page 168 Thursday, July 22, 2004 8:35 AM

ASCII/Hex Conversion Table

NOTES

168

PT Program Generator (PPG) v5.0

Page 181

2342.book Page 169 Thursday, July 22, 2004 8:35 AM

Appendix F Useful Bar Codes File Dump *

$ $

*

*

/

.

*

* % .

*

* % -

*

Program Mode

Set Date

Set Time

<CR> Only Protocol *

$ + $

- C A 0 0 E E *

*

$ + $

- C A 0 1 E E *

*

$ + $

- C A 0 2 E E *

ACK/NAK Protocol

Xmodem Protocol

User’s Guide

169

Page 182

2342.book Page 170 Thursday, July 22, 2004 8:35 AM

Useful Bar Codes

Reset Factory Defaults *

170

$ + S

- D 2 C 8 E E *

PT Program Generator (PPG) v5.0

Page 183

2342.book Page 171 Thursday, July 22, 2004 8:35 AM

Appendix G Troubleshooting Overview Use this section to solve common problems you might have while using PPG. Following is a list of troubleshooting topics: •

Fixing Corrupted Files on page 171.

•

Error Messages on page 173.

•

Technical Support on page 178.

Fixing Corrupted Files Occasionally a file becomes corrupt and won't open. The .scr file is highly structured. Several things can cause this problem. Open the .scr file using a word editor of some kind. Avoid any editors (such as Microsoft Word) which tend to add special control characters to the file. Notepad has been used successfully. Table 5. Conditions That Can Cause File Errors Output ‘SET DATE’( /* 250 100 */ Source(LITERAL "%."), Special(), Destination(SYSTEM), Branch(Output “SET TIME” , Output “SET TIME " /* 435 120 */ ) ), Broken lines Output “SET TIME”( /* 250 150 */ Source(LITERAL "%-"), Special(), Destination(SYSTEM), Branch(Output “SET BC” , Output “SET BC” ) ), As you can see the line after “SET TIME is out of place. User’s Guide

171

Page 184

2342.book Page 172 Thursday, July 22, 2004 8:35 AM

Troubleshooting

Call “REVIEW”( /* 420 30 */ Source(), Special(), Nodes copied from Destination(), another Branch(, Display “SCAN” ) ), application Pasting can cause the Branch line to remain blank or to have invalid Links. To avoid this problem, do not edit files manually. Always rely on PPG to create and edit the application files. Extra blank lines at the Place the cursor at the end of the file. Delete any extraneous characters end of the after the final ‘)’ character. file

Downloading the Program to the Portable If a few seconds pass with no messages, PPG was unable to make a connection with the portable •

Select a different serial port by selecting Options > Settings. Then select the File > Program the Portable to try again.

•

Make sure that the cable is firmly connected at both ends.

•

Try resetting the PT40 by pressing <CLR>+<ENT> while reloading the battery.

•

If you loaded a different program into your portable since downloading the sample program earlier, the portable may not be set to allow serial input, or the serial parameters may not be set correctly. In this case, scan the following bar code or select options in the portable to prepare it for downloading. *

172

/

.

*

PT Program Generator (PPG) v5.0

Page 185

2342.book Page 173 Thursday, July 22, 2004 8:35 AM

Error Messages

Error Messages This section lists error messages that you might come across in the PT Program Generator. Following each error message is a possible solution and, where applicable, a reference to the section of this manual in which you can find more information about solving the problem. If you continue to have trouble with your program, you can call PSC for technical assistance (refer to Technical Support on page 178).

PPG Error Messages Table 6. PPG Error Messages Error Message

Cannot start the PPG Compiler

Description The PPG Compiler application must be located in the same directory as the PPG application. If the PPG Compiler (PPGComp.exe) is missing, reinstall PPG to restore all files.

You have selected one or more nodes to delete. Removing these nodes could cause your applicaDeleting the selected node(s) could tion to behave unexpectedly. If you are sure you cause undesired results. Continue? want to delete the nodes, press Yes. If you want to cancel the delete command, press No.

User’s Guide

Do you want to overwrite the existing file?

You have selected the name of a file that already exists. Select Yes to overwrite the existing file with new information or select No to cancel the save process.

Duplicate node type and name. Enter a unique name for this node.

Each node in a frame or subroutine must have a unique type and name. You can have a copy node named “Start” and a Modify node named “Start” but you cannot have two copy nodes both named “Finish”. Rename one node so that each node has a unique type and name.

Error Connecting Nodes

The .scr file indicates a Link to a node that does not exist. This usually indicates that the .scr file has been corrupted. Contact Technical Support for assistance.

Error opening file

The file name may have been typed incorrectly or the file has been renamed or deleted.

173

Page 186

2342.book Page 174 Thursday, July 22, 2004 8:35 AM

Troubleshooting

Error Message

Description

Invalid file access code. 1 – 3 valid. Contact PSC Technical Support Invalid grid value. Enter any nonYou have entered a zero or no value for one or zero numeric value in both grid size both grid size fields. Set both grid size fields to fields and select OK. non-zero values and press OK. Invalid function node size. Enter any You have entered a zero or no value for one or non-zero numeric value in both size both function node size fields. Set both function fields and select OK. node size fields to non-zero values and press OK. Invalid operation node size. Enter You have entered a zero or no value for one or any non-zero numeric value in both both operation node size fields. Set both operation size fields and select OK. node size fields to non-zero values and press OK. This is not an international version of PPG. To Multiple-byte character sets are not support multiple-byte character sets such as Chisupported by this version of PPG. nese, you must obtain the international version of PPG. No active frame

The .scr file has been corrupted. Contact Technical Support for assistance

Please enter a name

The node has a blank name. Please enter a name up to 32 characters long.

PPG Graphics Library error. Contact An internal PPG error has occurred. Call PSC PSC technical support. technical support for assistance.

174

Subroutines cannot contain frame nodes

The .scr file indicates a frame within a subroutine. This usually indicates that the .scr file has been corrupted. Contact Technical Support for assistance

Subroutines cannot contain subroutine nodes

The .scr file indicates a subroutine within a subroutine. This usually indicates that the .scr file has been corrupted. Contact Technical Support for assistance

Too many display characters. Change your operation or create a new Output node.

Each output node can display up to 132 characters. To display more characters, create a second output node.

Unexpected type in destination

An unexpected value has been found in a node destination. This usually indicates that the .scr file has been corrupted. Contact Technical Support for assistance

PT Program Generator (PPG) v5.0

Page 187

2342.book Page 175 Thursday, July 22, 2004 8:35 AM

Error Messages

Error Message

Description

Unrecognized node type found

An unrecognized node type has been read. This usually indicates that the .scr file has been corrupted. Contact Technical Support for assistance.

PPGComp Error Messages Table 7. PPGComp Error Messages Error Message

Description

Can't access PPGXFER tool to download application

The PPGXfer application must be located in the same directory as PPGComp. If the PPGXfer (PPGXfer.exe) is missing, reinstall PPG to restore all files.

Can't allocate scanner to analyze source code

These errors indicate that there is insufficient memory available to run PPGComp. Close other applications and try again. If no other applications are open, you may need to reboot your PC before trying again.

An error occurred while creating the file. The directory may be write-protected or the drive may be full. Make sure there is Error creating <file name> room for the file and you are able to create files in that location. Error finding character

The specified character’s bitmap could not be found. Contact PSC Technical Support for assistance.

Error locating bitmap file

The file containing bitmaps for the selected language cannot be found. Reinstall PPG to restore all files. If the message persists, you may be running an outdated version of PPGComp. Contact PSC Technical Support for assistance.

Error opening <source file Error <source file name> is empty name>

User’s Guide