Page 10
D:\DOCS\PwrWedge\mini\refbook\ch1.fm
CODE PARAMETER
BETA DRAFT - Wednesday, 7/23/97 11:59 am
I.D. #
TYPE
Codabar/Ames
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
D1
D2
Enter 1 for On and 0 for Off.
Enable
20
On/Off
On or Off
Off
On
On
Minimum length
21
Value
01–50
01
01
04
Maximum length
22
Value
01–50
01
50
20
Send start/stop
23
On/Off
On or Off
Off
Off
Off
Codabar-to-CLSI conversion
24
On/Off
On or Off
Off
Off
Off
Wide intercharacter gaps allowed
25
On/Off
On or Off
Off
On
Off
MSI/Plessey
Enter 1 for On and 0 for Off.
Enable
26
On/Off
On or Off
Off
On
Off
Minimum length
27
Value
01–14
01
01
04
Maximum length
28
Value
01–14
01
14
10
Require 2 check digits
29
On/Off
On or Off
Off
Off
Off
2nd check digit Mod 11
2A
On/Off
On or Off
Off
Off
Off
Send check digit(s)
2B
On/Off
On or Off
Off
On
Off
Universal Product Code-A (UPC-A)
Enter 1 for On and 0 for Off.
Enable
30
On/Off
On or Off
Off
On
On
Send system digit
31
On/Off
On or Off
Off
On
On
Send check digit
32
On/Off
On or Off
Off
On
Off
Convert UPC-A to EAN-13
33
On/Off
On or Off
Off
On
Off
Universal Product Code-E (UPC-E)
Enter 1 for On and 0 for Off.
Use system digit 0
34
On/Off
On or Off
Off
On
On
Use system digit 1
35
On/Off
On or Off
Off
On
On
Convert UPC-E to UPC-A
36
On/Off
On or Off
Off
On
Off
Send system digit
37
On/Off
On or Off
Off
On
Off
Send check digit
38
On/Off
On or Off
Off
On
Off table continues
4
Mini PowerWedge
Page 11
D:\DOCS\PwrWedge\mini\refbook\ch1.fm
CODE PARAMETER
I.D. #
BETA DRAFT - Wednesday, 7/23/97 11:59 am
TYPE
European Article Numbering (EAN) Japan Article Numbering (JAN)
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
D1
D2
Enter 1 for On and 0 for Off.
Enable EAN-8/JAN-8
39
On/Off
On or Off
Off
On
On
Enable EAN-13/JAN-13
3A
On/Off
On or Off
Off
On
On
Convert EAN13 to ISBN
3B
On/Off
On or Off
Off
Off
Off
Transmit EAN/JAN checksum
3F
On/Off
On or Off
Off
Off
Off
UPC, EAN, JAN Extensions
Enter 1 for On and 0 for Off.
Allow 2-digit extensions
3C
On/Off
On or Off
Off
On
On
Allow 5-digit extensions
3D
On/Off
On or Off
Off
On
On
Require extensions
3E
On/Off
On or Off
Off
Off
Off
Enable
40
On/Off
On or Off
Off
On
On
Minimum length
41
Value
01–50
01
01
02
Maximum length
42
Value
01–50
01
50
20
Code 128
Enter 1 for On and 0 for Off.
Labelcode 4/5
Enter 1 for On and 0 for Off.
Enable
52
On/Off
On or Off
Off
On
Off
Convert
53
On/Off
On or Off
Off
Off
Off
Magnetic Stripe Channel 1
Enter 1 for On and 0 for Off.
Enable
44
On/Off
On or Off
Off
On
On
Required
45
On/Off
On or Off
Off
Off
Off
Preamble
48
String
*
//
†
1 //
//
//
1//§
//
Postamble
49
String
*
*Any supported keyboard keys, up to the maximum length supported by available total memory (about 80 characters) †Includes a space after the 1 § Includes a space before the 1 table continues
Programming Reference
5
Page 12
D:\DOCS\PwrWedge\mini\refbook\ch1.fm
CODE PARAMETER
I.D. #
BETA DRAFT - Wednesday, 7/23/97 11:59 am
TYPE
PREDEFINED DEFAULTS
ACCEPTABLE INPUT
Magnetic Stripe Channel 2
D0
D1
D2
Enter 1 for On and 0 for Off.
Enable
4A
On/Off
On or Off
Off
On
On
Required
4B
On/Off
On or Off
Off
Off
Off
Preamble
4E
String
*
//
†
2 //
// // On
Postamble
4F
String
*
//
2//§
California DL/ID alpha conversion
5C
On/Off
On or Off
Off
On
*Any supported keyboard keys, up to the maximum length supported by available total memory (about 80 characters) † Includes a space after the 2 § Includes a space before the 2
Other Controls
Enter 1 for On and 0 for Off.
Menu programming enable
B0
Value
00 = Menu off 02 = Menu on
02
02
02
Autoterminator
B1
Value
Any single ASCII character (00 = Off)
(CR)
(CR)
(CR)
ASCII capital to lowercase
B2
On/Off
On or Off
Off
Off
Off
Intercharacter delay
B3
Value
00–99 (milliseconds)
00
00
00
CCD/laser redundancy
B4
On/Off
On or Off
Off
Off
Off
Send assigned symbology identifiers*
B5
On/Off
On or Off
Off
On
Off
*A = UPC-A B = I 2 of 5 C = Code 39
G = EAN-8 H = MSI/Plessey I = Codabar/Ames
D = M 2 of 5 E = UPC-E F = S 2 of 5
J = Code 11 K = Code 128 M = EAN-13
N = Labelcode 4/5
Bar code preamble
B6
String
†
//
§
//
Bar code postamble
B7
String
†
//
**
//
†Any supported keyboard keys, up to the maximum length supported by available total memory (about 80 characters) CODEID // (includes a space after CODEID) ** (includes a space before § table continues
6
Mini PowerWedge
Page 13
D:\DOCS\PwrWedge\mini\refbook\ch1.fm
CODE PARAMETER
I.D. #
BETA DRAFT - Wednesday, 7/23/97 11:59 am
TYPE
Other Controls (continued)
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
D1
D2
Enter 1 for On and 0 for Off.
Good-read tone
B8
Value
00 = 3600 Hz 01 = 3840 Hz 02 = 4114 Hz 03 = 4430 Hz 04 = 2400 Hz 05 = 2618 Hz 06 = 2880 Hz 07 = 3200 Hz
Good-read number of beeps
B9
Value
01–04
01
01
01
00
00
00
04
04
04
Good-read beep duration
BA
Value
00 = 0.07 sec. 01 = 0.13 sec. 02 = 0.18 sec. 03 = 0.36 sec.
End-of-transmission beep
BB
On/Off
On or Off
Off
On
Off
03
03
03
Beeper volume
BC
Value
00 = Off 01 = Low 02 = Medium 03 = High
Interfunction delay
BE
Value
00–99 (milliseconds)
00
00
00
Use numeric keypad
BF
On/Off
On or Off
Off
Off
Off
Strip Motorola data identifiers
D3
On/Off
On or Off
Off
Off
Off
00
00
00
Laser/input modes
D4
Value
00 = Normal 01 = Autoscan 02 = Multiscan 03 = Symbol blinking 10 = Serial
Require keyboard
D5
On/Off
On or Off
On
On
On
Autoscan timeout
D6
Value
01–99 (minutes) 00 = 256 min.
30
30
30 table continues
Programming Reference
7
Page 14
D:\DOCS\PwrWedge\mini\refbook\ch1.fm
CODE PARAMETER
I.D. #
BETA DRAFT - Wednesday, 7/23/97 11:59 am
TYPE
Other Controls (continued)
ACCEPTABLE INPUT
PREDEFINED DEFAULTS D0
D1
Enter 1 for On and 0 for Off.
CTRL out at power-up
D7
On/Off
On = High Off = Low
Host device
C0
Value
*
On
On
On
None None None
*00 = IBM PC (international keyboard) 01 = IBM AT, PS/2 30-286, 50, 50Z, 60, 70, 80, 90, 95 (international keyboard) 02 = IBM PS/2 25, 30 (international keyboard) NOTE: Settings 00–02 work with DOS only. They transmit the ASCII character set and are not full-keyboard compatible. 10 = IBM PC (U.S. keyboard) 11 = IBM AT, PS/2 30-286, 50, 50Z, 60, 70, 80, 90, 95 (U.S. keyboard); ADDS terminals; NCR 2900 12 = IBM PS/2 25, 30 (U.S. keyboard) 15 = IBM and Telex terminals (102-key keyboard) 17 = IBM and Telex terminals (122-key keyboard); Decision Data models 3496 and 3781 21 = Macintosh (U.S. keyboard) 32 = TeleVideo models 935, 965, 9065, and 9320 40 = DEC (PowerWedge 10 Serial only) 42 = NEC PowerMate NOTE: The host devices listed above were supported at the time this user’s guide was printed. Additional devices may also be supported. Please contact your dealer or Customer Service for current information.
8
D2
Mini PowerWedge
Page 15
D:\DOCS\PwrWedge\mini\refbook\ch2.fm
BETA DRAFT - Wednesday, 7/23/97 11:59 am
2
CHAPTER
Full Keyboard Support Almost every key on your keyboard - including nonprinting keys, such as PGDN and CTRL - can be programmed into your Mini PowerWedge. The tables in this chapter list ASCII values, “mnemonic” values, and Code 39 equivalents for programming all keyboard keys. of the values listed in the ASCII column of the tables NOTE Some (for example, 03 for caps lock) are not really ASCII values.
T h e y a r e , h o w e v e r, t h e v a l u e s y o u s h o u l d u s e f o r programming the keys.
Use the ASCII values whenever you program your decoder with the menu method. For example, to turn on the caps lock key (value 03 from table 2-2) through menu programming, you would scan the bar codes for 0 and 3. Use the Code 39 values to create bar codes for batch programming or to include lowercase or nonalphanumeric characters in a bar code. For example, to include an exclamation mark (!) in a bar code, you would encode it as /A (slash capital a). ASCII mode for Code 39 must be enabled in the decoder NOTE Full for batch programming. Use mnemonics for on-screen and serial batch programming. For example, to encode the ENTER key, you would type (CR). sure to include the parentheses when you enter NOTE Be mnemonics. Some keys act immediately when read into the decoder. For example, the decoder transmits the page-down command to the computer as soon as it reads a bar code containing the characters %U$Z. Programming Reference
9
Page 16
D:\DOCS\PwrWedge\mini\refbook\ch2.fm
BETA DRAFT - Wednesday, 7/23/97 11:59 am
Other keys are not quite so simple. For example, the CTRL key has to be “turned” on and off. When you type CTRL+C, for instance, you hold the CTRL key down while you press C, and then you release the CTRL key. Three signals are sent to the host device: CTRL key on (down), C, CTRL key off (up). This is the way you need to think when encoding CTRL, ALT, SHIFT, and other keys requiring a key to be held down while another is pressed. To include the CTRL+C keystroke combination in a batch bar code, you would encode $RC$S. For on-screen programming for an IBM PC keyboard, you would need to enter (XC1)C(XC0). The ASCII equivalent for menu programming is 124313. Including a function key in a bar code can present a problem if your decoder is programmed to follow every bar code transmission with an autoterminator character. You can eliminate the autoterminator by including the “zap” character, $Z, in any bar code that you do not want followed by the autoterminator. For example, you would encode %U$A$Z to send function key F1 with no autoterminator after it. zap character does not eliminate preambles or NOTE The postambles. Table 2-1 lists the equivalents for keys that are common to many keyboards. For encoding keys from a specific keyboard, see the appropriate table from the following list: Computer or Terminal ADDS DEC Decision Data IBM PCs and compatibles IBM terminals Macintosh NCR 2900 NEC PowerMate TeleVideo Telex
Table 2-2 2-5 2-6 2-2 2-6 2-3 2-2 2-2 2-4 2-6
Page 12 16 20 12 20 14 12 12 15 20
For information about IBM terminals and illustrations of IBM keyboards, see the section beginning on page 17.
10
Mini PowerWedge
Page 17
D:\DOCS\PwrWedge\mini\refbook\ch2.fm
BETA DRAFT - Wednesday, 7/23/97 11:59 am
TABLE 2-1 Common keyboard keys Key
Code 39
ASCII Value
Key
Code 39
ASCII Value
Key
Code 39
ASCII Value
SP space
20
A
A
41 a
+A
61
!
/A
21
B
B
42 b
+B
62
"
/B
22
C
C
43 c
+C
63
#
/C
23
D
D
44 d
+D
64
$
/D
24
E
E
45 e
+E
65
%
/E
25
F
F
46 f
+F
66
&
/F
26
G
G
47 g
+G
67
'
/G
27
H
H
48 h
+H
68
(*
/H
28
I
I
49 i
+I
69
†
)
/I
29
J
J
4A j
+J
6A
*
/J
2A
K
K
4B k
+K
6B
+
/K
2B
L
L
4C l
+L
6C
,
/L
2C
M
M
4D m
+M
6D
-
- or /M
2D
N
N
4E n
+N
6E
.
. or /N
2E
O
O
4F o
+O
6F
/
/O
2F
P
P
50 p
+P
70
0
0 or /P
30
Q
Q
51 q
+Q
71
1
1 or /Q
31
R
R
52 r
+R
72
2
2 or /R
32
S
S
53 s
+S
73
3
3 or /S
33
T
T
54 t
+T
74
4
4 or /T
34
U
U
55 u
+U
75
5
5 or /U
35
V
V
56 v
+V
76
6
6 or /V
36
W
W
57 w
+W
77
7
7 or /W
37
X
X
58 x
+X
78
8
8 or /X
38
Y
Y
59 y
+Y
79
9
9 or /Y
39
Z
Z
5A z
+Z
7A
:
/Z
3A
@
%V
40
`
%W
60
;
%F
3B
[
%K
5B
{
%P
61
*When used as a string value in on-screen programming, must be entered as (( ) † When used as a string value in on-screen programming, must be entered as ( )) table continues
Programming Reference
11
Page 18
D:\DOCS\PwrWedge\mini\refbook\ch2.fm
BETA DRAFT - Wednesday, 7/23/97 11:59 am
Key
Code 39
ASCII Value
Key
Code 39
ASCII Value
Key
Code 39
ASCII Value
<
%G
3C
\
%L
5C
|
%Q
7C
=
%H
3D
]
%M
5D
}
%R
7D
>
%I
3E
^
%N
5E
~
%S
7E
?
%J
3F
_
%O
5F
Delete
%T
7F
Zap§
$Z
1A
§
Not an actual key; see information about the “zap” character on page 10
TABLE 2-2 IBM (or compatible) PC and NEC PowerMate keyboard keys Key
Mnemonic
Code 39
ASCII Value
Key
Mnemonic
Code 39
ASCII Value
F1
(X16)
%U$A
8001
↑
(UP)
%U%A
801B
F2
(X17)
%U$B
8002
↓
(DOWN)
%U%B
801C
F3
(X18)
%U$C
8003
←
(LEFT)
%U%C
801D
F4
(X19)
%U$D
8004
→
(RIGHT)
%U%D
801E
F5
(X20)
%U$E
8005
Caps Lock
(X3)
$C
03
F6
(X21)
%U$F
8006
Num Lock
(X4)
$D
04
F7
(X22)
%U$G
8007
Scroll Lock
(X5)
$E
05
F8
(X23)
%U$H
8008
Horizontal Tab
(TABR)
$I
09
F9
(X24)
%U$I
8009
Vertical Tab
(X10)
$K
0B
F10
(X25)
%U$J
800A
Enter
(CR)
$M
0D
F11
(X26)
%U$K
800B
Alt Off
(XA0)
$N
0E
F12
(X27)
%U$L
800C
Alt On
(XA1)
$O
0F table continues
12