Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 4

Mini PowerWedge Fixed-Station Decoder Programming Reference, pages 1 to 9

Pages 1 to 9 of 34

The original document is the PDF (935 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC Mini and Datalogic Mini

Page 1

MINI POWERWEDGE™ Fixed-Station Decoder

Programming Reference

Page 2

BETA DRAFT - 7/23/97 11:57 am D:\DOCS\PwrWedge\mini\refbook\copyrite.fm

© 1996

All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by a reviewer, who may quote brief passages in a review, or as provided for in the Copyright Act of 1976.

Apple™ and Macintosh™ are trademarks of Apple Computer, Inc. IBM® and PS/2® are registered trademarks of International Business Machines Corporation. Many of the designations used by manufacturers and sellers to distinguish their products are claimed as trademarks. Where these designations appear here and the authors were aware of a trademark claim, the designations have been printed with a trademark (™) symbol. The information contained in this document is subject to change without notice.

00-69N-00 3/96

Page 3

D:\DOCS\PwrWedge\mini\refbook\refbookTOC.fm

BETA DRAFT - Wednesday, 7/23/97 11:58 am

Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v CHAPTER 1

Programming Options . . . . . . . . . . . . . . . . . . . . . . . 1 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Matrix 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Standard 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Code 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Codabar/Ames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 MSI/Plessey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Universal Product Code-A (UPC-A) . . . . . . . . . . . . . . . . . 4 Universal Product Code-E (UPC-E) . . . . . . . . . . . . . . . . . 4 European Article Numbering (EAN), Japan Article Numbering (JAN). . . . . . . . . . . . . . . 5 UPC, EAN, JAN Extensions . . . . . . . . . . . . . . . . . . . . . . . 5 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Labelcode 4/5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Magnetic Stripe Channel 1 . . . . . . . . . . . . . . . . . . . . . . 5 Magnetic Stripe Channel 2 . . . . . . . . . . . . . . . . . . . . . . 6 Other Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

CHAPTER 2

Full Keyboard Support . . . . . . . . . . . . . . . . . . . . . . . 9 IBM Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Mini PowerWedge Programming Reference iii

Page 4

D:\DOCS\PwrWedge\mini\refbook\refbookTOC.fm CHAPTER 3

BETA DRAFT - Wednesday, 7/23/97 11:58 am

Connector Configurations . . . . . . . . . . . . . . . . . . . . 23 Host Interface Connector . . . . . . . . . . . . . . . . . . . . . . . 23 Input Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Serial Input Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Cloning Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Bar Code Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 iv

Mini PowerWedge

Page 5

D:\DOCS\PwrWedge\mini\refbook\intro.fm

BETA DRAFT - Wednesday, 7/23/97 11:58 am

Introduction This programming reference is a supplement to the Mini PowerWedge User’s Guide. The user’s guide contains programming bar codes that will meet the needs of most users. However, additional programming of the Mini PowerWedge may be required for some applications. This booklet provides the information you need. Chapter 1 contains all the parameter settings for the Mini PowerWedge. Chapter 2 provides information about using ASCII values, mnemonics, and Code 39 equivalents for programming keyboard keys into the Mini PowerWedge. Chapter 3 identifies pin assignments for the connectors on the Mini PowerWedge and for the cloning cable and serial cable that are used with the decoder. complete information about the Mini PowerWedge, NOTE For including installation and programming instructions, see the Mini PowerWedge User’s Guide.

Programming Reference v

Page 6

D:\DOCS\PwrWedge\mini\refbook\intro.fm

BETA DRAFT - Wednesday, 7/23/97 11:58 am

Mini PowerWedge

Page 7

D:\DOCS\PwrWedge\mini\refbook\ch1.fm

BETA DRAFT - Wednesday, 7/23/97 11:59 am

CHAPTER

1

Programming Options This chapter contains parameter settings for the Mini PowerWedge. You can use the bar code menu on the last page of this book or another method to program the decoder. (For information on programming the Mini PowerWedge, see chapter 3 of the Mini PowerWedge User’s Guide.) Table 1-1 lists programming I.D. numbers for predefined defaults. Table 1-2 lists cloning, display, and save-and-exit settings. Table 1-3 provides the following information:

q Code Parameter is the “human” name for programming options. q I.D. # is the “decoder” name for programming options. For example, if you wanted to set a Code 39 minimum label length, you would enter 01 when programming the decoder. Programming I.D. numbers given in this appendix can be used with all programming methods.

q Type tells what kind of setting to use for each code parameter: q On/Off is a toggle. 1 turns the parameter on, and 0 turns it off. q Value requires a two-character entry (e.g., 02 for two beeps after each good read, or 05 for a length of five).

q String uses one or more ASCII characters, followed by // to indicate the end of the string.

q Immediate takes effect as soon as the I.D. number is entered. q Acceptable Input gives the settings or range of settings that you can use for each code parameter.

q Predefined Defaults tells how the parameter is set when you select predefined default D0, D1, or D2.

Programming Reference

1

Page 8

D:\DOCS\PwrWedge\mini\refbook\ch1.fm

BETA DRAFT - Wednesday, 7/23/97 11:59 am

TABLE 1-1 Predefined defaults SETTING

I.D. #

TYPE

Predefined default set 0

D0

Immediate

Predefined default set 1

D1

Immediate

Predefined default set 2

D2

Immediate

TABLE 1-2 Cloning, display, and save-and-exit settings SETTING

I.D. #

TYPE

Cloning

EC

Immediate

Display settings (on-screen programming only)

ED

Immediate

Save and exit

EE

Immediate

Exit only, no save

EF

Immediate

TABLE 1-3 General programming parameters

CODE PARAMETER

I.D. #

TYPE

Code 39

ACCEPTABLE INPUT

PREDEFINED DEFAULTS D0

D1

D2

Enter 1 for On and 0 for Off.

Enable

00

On/Off

On or Off

Off

On

On

Minimum length

01

Value

00–50

00

00

00

Maximum length

02

Value

01–50

01

50

20

Enable checksum

03

On/Off

On or Off

Off

Off

Off

Send checksum

04

On/Off

On or Off

Off

Off

Off

Full ASCII mode

05

On/Off

On or Off

Off

On

On

MIL-STD-1189 support

07

On/Off

On or Off

Off

On

Off table continues

2

Mini PowerWedge

Page 9

D:\DOCS\PwrWedge\mini\refbook\ch1.fm

CODE PARAMETER

I.D. #

BETA DRAFT - Wednesday, 7/23/97 11:59 am

TYPE

Interleaved 2 of 5

ACCEPTABLE INPUT

PREDEFINED DEFAULTS D0

D1

D2

Enter 1 for On and 0 for Off.

Enable

08

On/Off

On or Off

Off

On

On

Minimum length

09

Value

02–50

02

02

06

Maximum length

0A

Value

02–50

02

50

10

Enable checksum

0B

On/Off

On or Off

Off

Off

Off

Send checksum

0C

On/Off

On or Off

Off

Off

Off

Use lengths 6 and 14 only

0D

On/Off

On or Off

Off

Off

Off

Matrix 2 of 5

Enter 1 for On and 0 for Off.

Enable

10

On/Off

On or Off

Off

On

Off

Minimum length

11

Value

01–50

01

01

06

Maximum length

12

Value

01–50

01

50

10

Enable checksum

13

On/Off

On or Off

Off

Off

Off

Send checksum

14

On/Off

On or Off

Off

Off

Off

Standard 2 of 5

Enter 1 for On and 0 for Off.

Enable

15

On/Off

On or Off

Off

On

Off

Minimum length

16

Value

01–50

01

01

06

Maximum length

17

Value

01–50

01

50

10

Enable checksum

18

On/Off

On or Off

Off

Off

Off

Send checksum

19

On/Off

On or Off

Off

Off

Off

Use 2-bar start/stop

1A

On/Off

On or Off

Off

Off

Off

Enable

1B

On/Off

On or Off

Off

On

Off

Minimum length

1C

Value

01–50

01

01

04

Maximum length

1D

Value

01–50

01

50

10

Require 2 check digits

1E

On/Off

On or Off

Off

Off

Off

Send check digit(s)

1F

On/Off

On or Off

Off

On

Off

Code 11

Enter 1 for On and 0 for Off.

table continues

Programming Reference

3