Appendix C: Factory Default Configuration Table C-1. Factory Default Configuration

C-1

Cmd

Description

@Z

Enable Scanning of Programming Labels

AE03

Beeper/Good Read duration = 135ms

AF03

Good Read LED = 135ms

BC

DisableRead Verification

BH60

Laser time-out = six seconds

DF

Select 9600 baud

EM

Set serial data word to 8 bits, one stop bit and no parity

FA

Clear Label Formats to Default (%D%)

HA

Disable all Flow Control Protocols. Xon/Xoff is off, CTS mode is None. RTS mode is forced to RTS high ready to receive (default for CTS)

HN

RTS High Indicates Scanning in Progress (default for RTS)

KA

Disable Preamble

LB

Postamble = CR, LF (0x0D 0x0A)

NA

Enable LaserSense mode

ND

Disable Continuous Scanning mode

NH24

Double Read timeout = 600ms

NJ/NL

Disable No Read timeout

NY

Disable No Read message.

OB

Enable standard Code 39

OD

Disable Code 39 check character

OF

Disable transmit of the Code 39 start/stop characters

OK

Disable transmission of the Code 39 check character

PA

Disable Interleaved two of five

PO

Disable transmission of Interleaved 2 of 5 check digit

PQ

Disable Standard two of five (STF)

PV

Disable transmission of STF check digit

LM520 Scanner Integration & Programming Manual

Page 47

Cmd

Description

QC

Enable UPC-A

QH

Disable expansion of UPC-E

QL

Enable UPC-E

QX

Disable all UPC 2 and 5 digits supplementals (UPC-A, UPC-E)

QY15

Number of scanning retries to build UPC/EAN supplementals = 15

RC

Enable EAN-13

RP

Enable EAN-8

RS

Disable all EAN 2 and 5 digit supplementals (EAN 8, EAN13)

TC

Enable Code 128

TE

Disable transmission of Code 128 function codes

UA

Disable Code 93

VA

Disable Codabar

VC

Disable transmission of Codabar start/stop characters

R44-2016

C-2

Page 48

Appendix D: LM520 Programming Labels The most common method of configuring the LM520 scanner is by sending commands from the host. (see Configuration of the LM520). The bar codes contained in this table are a limited set of the programmable options. Feature

Table D-1. Programming Labels Code Bar Code

Reset Factory Defaults

Baud rate - 9600

Data Format - 8 data bits, 1 stop bit, no parity

Z1 ³

Z

1

³

D

F

E

M

³

H

A

³

H

B

³

H

L

³

Q

M

A

E

0

³

@

Z

³

@

Y

DF

EM ³

Enable no flow control

Enable software flow control

Enable hardware flow control

Enable all symbologies

Turn beeper off

HA

HB

HL

QM

AE00 ³

Enable label programming

Disable label programming

D-1

0

@Z

@Y

LM520 Scanner Integration & Programming Manual

Page 49

Programming Labels (continued) Feature Set beeper duration to 135ms

Set scanner timeout to 6.0 seconds

Set scanner timeout to 9.9 seconds

Set scanner to no timeout until bar code is decoded

Scan now, until timeout

Continuous scan ON

Continuous scan OFF

LaserSense ON

LaserSense OFF

LaserSense Range (Default)

LaserSense Range Min.

LaserSense Range Max.

R44-2016

Code

Bar Code

AE03 ³

A

E

0

3

³

B

H

6

0

³

B

H

9

9

³

B

H

0

0

³

Z

D

0

0

³

N

C

³

N

D

³

N

A

³

N

B

BH60

BH99

BH00

ZD00

NC

ND

NA

NB

NG60 ³

N

G

6

0

³

N

G

4

5

³

N

G

7

0

NG45

NG70

D-2

Page 50

Appendix E: ASCII Conversion Table Table E-1. ASCII Conversion Table

E-1

CHAR

DEC

HEX

CHAR

DEC

HEX

CHAR

DEC

HEX

NULL

0

00

0

48

30

[

91

5B

SOH

1

01

1

49

31

\

92

5C

STX

2

02

2

50

32

]

93

5D

ETX

3

03

3

51

33

^

94

5E

EOT

4

04

4

52

34

_

95

5F

ENQ

5

05

5

53

35

`

96

60

ACK

6

06

6

54

36 a

97

61

BEL

7

07

7

55

37 b

98

62

BS

8

08

8

56

38 c

99

63

HT

9

09

9

57

39 d

100

64

LF

10

0A

:

58

3A e

101

65

VT

11

0B

;

59

3B f

102

66

FF

12

0C

<

60

3C g

103

67

CR

13

0D

=

61

3D h

104

68

SO

14

0E

>

62

3E i

105

69

SI

15

0F

?

63

3F j

106

6A

DLE

16

10

@

64

40 k

107

6B

DC1

17

11

A

65

41 l

108

6C

DC2

18

12

B

66

42 m

109

6D

DC3

19

13

C

67

43 n

110

6E

DC4

20

14

D

68

44 o

111

6F

NAK

21

15

E

69

45 p

112

70

SYN

22

16

F

70

46 q

113

71 72

ETB

23

17

G

71

47 r

114

CAN

24

18

H

72

48 s

115

73

EM

25

19

I

73

49 t

116

74

SUB

26

1A

J

74

4A u

117

75

ESC

27

1B

K

75

4B v

118

76

FS

28

1C

L

76

4C w

119

77

GS

29

1D

M

77

4D x

120

78

RS

30

1E

N

78

4E y

121

79

US

31

1F

O

79

4F z

122

7A

SP

32

20

P

80

50

{

123

7B

!

33

21

Q

81

51

|

124

7C

“

34

22

R

82

52

}

125

7D

#

35

23

S

83

53

~

126

7E

$

36

24

T

84

54

DEL

127

7F

%

37

25

U

85

55

&

38

26

V

86

56

*

39

27

W

87

57

(

40

28

X

88

58

)

41

29

Y

89

59

*

42

2A

Z

90

5A

+

43

2B

‘

44

2C

-

45

2D

.

46

2E

/

47

2F

LM520 Scanner Integration & Programming Manual