Page 5

Section 1 The LM520 Bar Code Scanner Overview The LM520 scanner is a compact, decoded, single-line scanner for fixed position or embedded applications, such as conveyor, library, document tracking, chemical analyzers, vending machines, point-of-sale (POS) terminals, and other attended or unattended scanning applications. The LM520 is a complete scanning system, ready to plug in and scan. The LM520 presents a fast, easy and low-cost way to incorporate scanning into any application where you need to read a bar code. A typical system using the LM520 scanner consists of the scanner itself and a host system such as a PC, POS system, or package sorting system. The host system controls the scanner and receives the decoded bar code data produced by the scanner. The laser in the LM520 scanner emits coherent visible light. When a bar code passes through the scanner’s beam, light is reflected off the bar code. The scanner collects this reflected light, processes it into a digital signal and decodes it into data that can be used by the host system. In some cases the data may be processed further by the scanner before being transmitted to the host. The LM520 has four different operational modes which can be used to scan a bar code. The four operational modes include: • an external switch such as an output line from a Programmable Controller (also known as a PLC) can be used to enable scanning • software commands from the host system • continuous scanning operations, and • a unique PSC motion detection circuitry called LaserSense™. This circuitry allows the LM520 to only scan when an object is passed in front of it. The various modes are selected via host commands or special programming bar codes.

R44-2016

1

Page 6

The LM520 Bar Code Scanner

Section 1

Unpacking the LM520 The LM520 bar code scan scanner is shipped in custom packaging. Carefully open the package, and remove the scanner from the packing material. The LM520 standard configuration includes: • LM520 scanner • power supply • mounting hardware (two bolt studs with nuts) • interface cable - male DB9 (scanner side) [with optional beeper if ordered] • diskette with this manual and other information When you open the shipping carton, visually inspect the package’s contents. If any parts are damaged or you need additional hardware, please contact your reseller or the PSC Customer Support Center at 1-800-547-2507.

Scanner Care The LM520 bar code scanner contains sensitive components which require special handling. PSC Inc. may not warrant damage due to improper handling. • Do not open the scanner’s case. Doing so will void the warranty. • Avoid touching the front window. Fingerprints will degrade the scanner’s performance. • Only clean the scan window when visual inspection reveals dirt or residue. Remove lint or foreign material be present with filtered clean air. Remove fingerprints or other residue using clean, cotton-tipped applicators dipped in isopropyl alcohol, or with soft tissues dipped in high-quality lens or eyeglass cleaner. Do not reuse cotton-tipped applicators or tissues. • Do not scrub the window. • Never wipe the window with a dry tissue or applicator.

2

LM520 Scanner Integration & Programming Manual

Page 7

Section 2 Mounting the LM520 The LM520 bar code scanner is designed to be mounted to a stand in a fixed position. This section describes the layout of the mounts for optimum scanner performance.

General Considerations Although the LM520 bar code scanner has been designed to be impact-resistant, it is important to consider the effect of the environment on the scanner. In particular, the mounting scheme should minimize the possibility of foreign objects contacting the window’s surface. Such contact will damage the window over time and reduce the scanner’s performance. The mounting design should also take into consideration the clearance needed for the power supply and interface cables. These cables should be routed away from the operator’s working area in attended applications.

Mounting System integration is made easy with the LM520’s unique mounting design. Six mounting grooves in the scanner’s sealed enclosure enable mounting on any one of four sides. When looking at the back of the scanner, these slots are located as shown in Figure 1. Figure 1. Mounting 1.00" (2.54cm)

Mounting Slots (6 total)

0.675" (1.71cm)

Mounting Slots 6 7 8 9 1 2 3 4 5

0.675" (1.71cm)

Mounting Slots

LM520 Scanner

0.50" (1.27cm)

0.50" (1.27cm)

Appendix B, Mechanical Specifications shows mechanical drawings of the precise position of the mounting slots relative to the scanning laser beam.

R44-2016

3

Page 8

Mounting the LM520

Section 2

Mounting the Scanner Stand-Alone For most instances using an adjustable mount is recommended. The position of the scan line can be fine-tuned during actual installation and the scanner’s distance from the scanned object can be easily changed. The location of the operator should also be considered for attended applications. Care should be taken to position the scanner to minimize the possibility of the operator overturning the scanner, spilling liquid on the scanner, inadvertently unplugging the cables, and so on.

Integrating the Scanner to Read at the Proper Distance When deciding how to mount the LM520, there are many criteria that must be considered. First, there are minimum and maximum distances that the bar code can be from the front of the scanner to properly read, depending on the size of the bar code. These distances, or depth of field, are specified in Appendix A, Technical Specifications. Second, the scanner must be positioned so that the bar code to be read is not “square” or parallel to the front of the scanner. The scanner must have at least 3 degrees skew angle to operate properly. See Appendix B, Mechanical Specifications for such information as skew, pitch, and the scanner’s mechanical parameters. Third, the scanner must be positioned so that the scan line will be long enough to cover the entire bar code. The scan line should exceed the width of the bar code since only about 80% of the scan line is usable (see Figure 2). Use the following formula to calculate the expected usable line length (l) at a given distance (d): l = [(d+0.88in) x 2 x tan (q)] x 0.8 (if d is measured in inches) or l = [(d+2.34cm) x 2 x tan (q)] x 0.8 (if d is measured in centimeters) where l = usable line length d = distance from the front of scanner q = half of the scan angle, (23° ± 2.0°)

4

LM520 Scanner Integration & Programming Manual

Page 9

Section 2

Mounting the LM520

Figure 2. Mounting the Scanner

LM520 scanner q= d l = 80% of scan line

.88" 2.34cm

Integrating the Scanner Behind a Window When the LM520 scanner is integrated into a larger system, additional factors must be taken into account. The most important of these is an additional window placed between the LM520 and the bar code to be read. While an additional window provides protection for the LM520, it will also degrade the scanner’s performance due to the need for the laser light to traverse two additional optical surfaces passing through to the bar codes, and the reflected light returning. Following the instructions in this section will help optimize the amount of outgoing light that reaches the bar code and the amount of reflected light that is collected by the scanner. The LM520 scanner emits a laser beam in the form of a scan line. The beam’s light exits the scanner’s window and reflects off the bar code symbol. The reflected light returns through the window, and is collected with a photodiode. As in any optical system, any type of window causes a reduction in the amount of light that exits or enters the scanner since some of the laser light is lost due to surface reflection.

R44-2016

5

Page 10

Mounting the LM520

Section 2

The design and placement of the window is critical for optimum system performance. The following issues must be considered. • The window must not block outgoing laser light. • The window must not block laser light reflected from the bar code. Figure 2 shows the minimum size and position of the window along the horizontal and vertical axes, respectively. The minimum window size must increase as the distance between the scanner and the window increases. This is necessary to accommodate the width of the scan line. • Reflections of outgoing laser light caused by the window or other reflective surfaces should not reach the front window of the scanner. Determine the window tilt based on your application. The tilt angle of the window (that is, its position relative to the optical axis or center-line) is important because a portion of the emitted light will always be specularly reflected from each of the two window surfaces. This reflected light must not reach the scanner’s window either directly or via multiple reflections from other parts of the system. Figure 3. Tilt Angle Reflected light

0.880" 22.34mm Angle = 103.7˚

Window

0.125" 3.18mm

Nominal Beam Path 0.820" 20.83mm d = 1.250" 31.74mm

[

(0.65 )] = 103.7

Angle = 90 + 0.5 arctan 1.25

6

LM520 Scanner Integration & Programming Manual

Page 11

Section 2

Mounting the LM520

An example of acceptable system window inclination is shown in Figure 2. As can be seen, moving the system window closer to the scanner makes it necessary to increase the window angle with respect to vertical. Less inclination is necessary if the reflection is directed below, rather than above the scanner, since laser light is emitted near the bottom of the scanner’s window and collected near the top of the scanner’s window. If the light reflected from the window will be deflected above the scanner, the required window angle (from horizontal) is given by:

[

Angle = 90 + 0.5 arctan

Angle = 90 + 0.5

(0.65d )] if d is measured in inches

[ arctan ( 1.65d )] if d is measured in cm

If the light will be deflected below the scanner, the required window angle (from horizontal) is given by:

Angle = 90 - 0.5

[ arctan ( 0.2d )] if d is measured in inches [

Angle = 90 - 0.5 arctan

( 0.51d )] if d is measured in cm

The window material you select depends on the anticipated environment and your scanner’s intended use. Appropriate window materials include glass, sapphire, and plastic. Glass, and especially sapphire, have adequate surface hardness for most applications. However, if you use any type of plastic, it should have a protective hard-coat on the exposed surface. The hard-coat will protect the plastic surface from damage if the system window needs to be cleaned. In addition to hard-coating, some window applications may require special treatment such as antistatic or antireflection coatings. In general, do not use antiglare coatings due to undesirable polarization and diffusion effects.

R44-2016

7

Page 12

Mounting the LM520

Section 2

Electrical Interface The LM520 scanner communicates with the host over a standard DB-9 connector. The pinouts for the connector are shown in Table 1. Table 1. Electrical Interface Specifications Direction Signal

Function

Pin #

(relative to LM520)

1

Output

Beeper/ Good Read 1

5VDC output signal used to drive an audio indicator.

2

Output

TX

Serial asynchronous RS232C level data transmitted to the host. NRZ format and user programmable for word format and baud rate. (Default: 9600 baud, 8 data bits, no parity, 1 stop bit).

3

Input

RX

Serial asynchronous RS232C level data received from the host. NRZ format and user programmable for word format and baud rate. (Default: 9600 baud, 8 data bits, no parity, 1 stop bit).

4

Output

No Read 2

This signal is asserted at the end of a scanning cycle if no label is decoded and will remain asserted until: 1. A successful decode occurs, or 2. A user specified timeout period elapses. This may be configured in 100ms increments from 100 ms to 9900 ms (9.9 seconds). Refer to the section titled No Read Output. NOTE: If the timeout is used, the signal will be immediately deasserted if a software scan command, hardware scan trigger on pin 9 or a LaserSense scan occurs before the user specified time elapses. Setting a timeout is not available in Continuous Scan mode.

5

Input

Gnd

Power supply/signal ground.

6

Input

Vcc

Power supply input voltage (4.75 - 12.0VDC)

7

Input

CTS

RS232C Clear to send control line.

8

Output

RTS

RS232C Request to send control line.

Scan Trigger 3

Ground on this input initiates bar code scanning. Scanning will continue until either: (a) this line returns to high (5VDC) level, or (b) this line is disconnected, or (c) the programmed time period expires, or (d) a bar code is decoded.

9

Input

1

Beeper Drive/Good Read source current must be limited to 50mA with a maximum voltage of 5VDC. No Read output will source 15mA @ 5VDC. The maximum sink current must be limited to 200mA with a maximum voltage of 14VDC. 3 Scan trigger signal must be limited to a maximum input voltage of 5VDC with a maximum input current of 10mA. 2

8

LM520 Scanner Integration & Programming Manual

Page 13

Section 2

Mounting the LM520

Interface Cable Schematic The drawing in Figure 4 shows a schematic view of the electrical connection between the scanner and the host. Figure 4. Interface Cable Schematic DB9-P

DB25-S

Power Supply 4.75 - 12VDC

1 2 3 4 5 6 7 8 9

ORANGE YELLOW VIOLET GREEN RED WHITE BROWN BLUE

3 2 7 4 5 1

BEEPER/GOOD READ TXD RXD NO READ GND VCC IN CTS RTS TRIGGER_IN

3

2 HOST END Connector is a 2.5 mm stereo plug for the scan trigger, no read signal and power supply ground.

R44-2016

SCANNER END Beeper (if applicable)

9