APPENDIX B SPECIFICATIONS PHYSICAL SPECIFICATIONS SCANNER

Depth = 3.45" (8.76cm) Length = 7.6" (19.3cm) Width = 9.0" (22.9cm) Weight = 4 lb 11oz (2.13 kg)

AC/DC POWER SUPPLY

Length = 5.0" (12.7 cm) Width = 3.0" (7.6 cm) Height = 1.5" (3.8 cm) Weight = 1.0 lb (.6 kg)

30

HS1250 User's Guide

Page 33

ENVIRONMENTAL SPECIFICATIONS OPERATION TEMPERATURE

10°C (50°F)

40°C (104°F)

HUMIDITY

5 - 90 % (non-condensing)

AMBIENT LIGHT

200 footcandles (2150 Lux) maximum

STORAGE TEMPERATURE

-40°C (-40°F)

70°C (158°F)

HUMIDITY

5 - 95 % (non-condensing)

R44-1430

31

Page 34

ELECTRICAL SPECIFICATIONS USE ONLY POWER SUPPLY (P/N 8-0133) OR OTHER PSC APPROVED POWER SUPPLY. The AC/DC Power Supply provides three dc voltages to the HS1250 ; +12 volts, -12 volts and +5 volts. Typical current draw is: +12vdc ................................... 315mA (normal operation) ...............................................665mA (during start-up) -12vdc .................................... 45mA +5vdc ..................................... 230mA Typical power consumption is approximately 5.5 watts during operation, 9.7 watts during start-up and 4.4 watts in Sleep Mode.

INPUT POWER The HS1250 scanner receives DC power from an external power supply.

EXTERNAL POWER SOURCE 90- 265 VAC

47 - 63 Hz

< 10.0 Watts

AC TO DC POWER SUPPLIES HS1250 uses one power supply equipped with an IEC power cord that matches your country's requirements. This unit accepts all of the following line voltages. COUNTRY AC VOLTAGE Australia -------------------------------- 240 Benelux --------------------------------- 220 Canada ------------------------------ 115/120 France ---------------------------------- 220 Germany -------------------------------- 220 Italy ----------------------------------- 220 Japan ---------------------------------- 100 Mexico ------------------------------ 115/120 Scandinavia ------------------------------ 220 Spain ---------------------------------- 220 United Kingdom --------------------------- 240 United States -------------------------- 115/120