The text of a manual · part 7 of 10
HS1250 User's Guide: Routine Maintenance
Pages 26 to 28 of 48, from HS1250 User's Guide
The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC HS-1250 and Datalogic HS-1250
Page 26
ROUTINE MAINTENANCE HS1250 maintenance procedures consist of window cleaning and window replacement.
CLEANING The scanner actually has two windows; upper and lower. While the top of the upper scan window may require periodic cleaning due to spillage, surface dust, etc., other window surfaces are unlikely to need much attention. In the event you do need to clean them, here's how:
NOTE ALCOHOL or ACETONE
Although the scanner windows are made of high quality, scratch resistant glass, they should not be subjected to abrasive cleaners or pads. Additionally, do not use alcohol or acetone.
ABRASIVES
Reference the illustrations on page 25. 1.
Insert a coin into the slot along the scanner’s edge and use it to gently pry the top cover from the scanner.
2.
Spray ordinary glass cleaner onto a lint free, nonabrasive cleaning cloth.
3.
Gently wipe the underside of the upper window.
4.
Clean the top surface of the lower window as needed.
5.
Reinstall the top cover, inserting the alignment tabs in their respective slots. Press down along all edges to seat.
6.
Clean the upper window top surface as described above.
This completes the window cleaning instructions.
24
HS1250 User's Guide
Page 27
1.
R44-1430
2.
3.
4.
5.
6.
25
Page 28
WINDOW REPLACEMENT If the scanner's upper window becomes scratched, it can be easily replaced by following the procedures on this page. 1.
Insert a coin into the slot on the scanner’s edge and use it to gently pry the top cover from the scanner.
2.
Grasp the top cover firmly and carefully press the window out from the bottom side. Use care to avoid dropping the window as it pops loose from the seal and remember to dispose of it properly.
3.
Press one edge of the window against its seal, aligning the notched corners and ensuring that the seal is not pinched or rolled.
4.
Tilt the window into place, pushing down firmly to seat the glass along all edges.
5.
Clean the windows and replace the top cover as described under Cleaning.
This completes the window replacement procedure.
1.
2.
3. 26
4. HS1250 User's Guide