Page 13

VERIFYING SCANNER OPERATION Prior to installation, we recommend that you connect the scanner and power supply to AC power to ensure that the scanner is fully functional. 1. 2. 3.

Plug the DC power connector from the AC/DC power supply into the scanner. Connect the IEC end of the AC power cord into the AC/DC power supply. Plug the AC power cord into an AC power outlet.

1.

2.

The scanner should emit a tone indicating that it has passed the PowerUp Self-Test routine, and the green lamp will light continuously indicating that the scanner is ready for operation. Since the scanner is not connected to a host terminal, it may only read one or two labels before it must be reset. This is normal because some terminal interfaces require the scanner to store label data until the POS terminal signals that it is ready to receive the data. If the scanner powers-up, but the green lamp begins flashing and the speaker repeats a series of tones, go to the section titled, Problem Isolation.

3. R44-1430

11

Page 14

INSTALLATION COUNTER MODIFICATION The HS1250 scanner is designed to optimize usable counter space by mounting horizontally flush with the counter. The following instructions provide optional mounting plans, allowing flexibility in method, while ensuring a stable and secure installation. 1.

Choose the installation location. Product flow, cable routing and ease of use should all be considered.

2.

Because of its durable construction, the HS1250 can be mounted with support from the bottom (Option a) or it can be mounted using a routed ledge to support only the “wings” located on both ends of the scanner (Option b).

1.

Product Flow

Cable Routing

2.

Mount Option a

12

Mount Option b

HS1250 User's Guide

Page 15

3.

For Option a, cut a hole in the countertop using the dimensions below, with a corner radius of !f" (6.35mm). The shelf supporting the scanner should be 3.45" (closest fractional = 3@h(f") (8.76cm) below the top of the counter.

OPTION A Radius !f" (6.35mm) 4x

9(ds" (23.57cm)

7!a!h" (19.52cm)

Counter Cut-Out

3.45" 3@h(f" (8.76cm)

Shelf Depth

R44-1430

13

Page 16

4.

For Option b, reference the counter cutout dimensions below. Radius corners at !f" (6.35mm). To adequately support the scanner, counter thickness must be at least #f" (19mm).

OPTION B Radius !f" (6.35mm) 4x

Routed Edge

8#f" (22.22cm)

7!a!h" (19.52cm)

Routed Edge

Counter Cut-Out

Rout (ds" (7.1mm) 2x

Rout #k" (9.5mm) 2x Min. Thickness #f" (19mm)

Rout Detail

14

HS1250 User's Guide

Page 17

HOOKUP 1.

Route all cables up through the opening.

2.

Connect the interface cable to the scanner and secure it with the mounting screw, ensuring that the cable is routed inside the cable clip.

3.

Attach the DC power connector from the AC/DC power supply to the scanner's power connector.

4.

Connect the IEC power cord to the AC/DC power supply.

You are now ready to power-up the scanner and POS system. Since powerup procedures vary for different systems, contact the site technical support specialist, reference the POS system operator's manual, or consult the manufacturer to ensure that these procedures are performed properly.

R44-1430

1.

2.

3.

4. 15

Page 18

POWER-UP PROCEDURE The system power-up procedure may vary depending on the requirements of your Point-of-Sale (POS) system. It is always a good idea to power-down (switch off) all equipment prior to connecting cables. Check with your system supervisor and/or refer to the terminal operator's manual for proper power-down and power-up procedures for your system. Before beginning this procedure, disconnect power from the scanner (if connected). 1.

Power-down your terminal.

2.

Connect the scanner interface cable to the POS terminal.

3.

Connect the IEC power cord to the AC/DC Power Supply and then to an AC outlet. It is recommended that the IEC power cord of the AC/DC power supply be connected to the same AC outlet as used by the POS terminal.

4.

Power-up the terminal.

5.

Power-up the scanner.

6.

Verify that data is being properly communicated between the scanner and your POS terminal by scanning a few items.

You have completed the scanner installation and power-up procedures. If problems occur, follow the procedures titled Problem Isolation on the next page. If you want to modify the scanner's interface parameters or change the user interface (e.g. volume), order the HS1250/VS1200 Programming Kit (PSC Part Number R44-1340).

16

HS1250 User's Guide

Page 19

CONNECTING THE SCANNER

On I

1

1.

Switch the terminal power off.

Off O

2.

Connect the interface cable to the terminal.

2

To Scanner

3

4.

3.

Connect the IEC power cord to the AC outlet

Switch on the terminal power. Verify the system's operation by scanning a few product labels.

On I

4

Off O 5.

You have completed the installation procedures.

R44-1430