The text of a manual · part 2 of 10
HS1250 User's Guide, pages 5 to 9
Pages 5 to 9 of 48: Product Overview; Manual Overview; Controls, Indicators
The original document is the PDF (3.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC HS-1250 and Datalogic HS-1250
Page 5
PRODUCT OVERVIEW The HS1250, a compact high-performance scanner, is designed to mount horizontally in your counter, leaving valuable checkstand ‘real estate’ clear for items and workspace. Designed for grocery and hypermarket applications, the HS1250's cast aluminum construction and rugged top design makes it ideal for high volume installations as well as moderate to low volume applications such as variety, drug and convenience stores. Slide-through scanning enhances productivity and throughput, while eliminating the need to lift items being scanned. The HS1250 also provides a connection for an optional undecoded handheld scanner, such as the PSC model SP400, allowing heavy or large items to be scanned without removal from the shopping cart. The HS1250's sturdy design allows a couple of different mounting options. Power to the scanner is supplied via a remote AC/DC power supply, adding to the ease of installation. Advanced hardware and software afford the highest levels of scanning performance in the smallest possible package.
HS1250 features include: • • • •
• • aggressive scan pattern minimizes the need for label orientation flush horizontal mounting leaves the entire counter work space clear modular design allows easy use within multiple applications programmable features let the user customize scanner settings, optimizing performance and tailoring advanced features for each installation automatic shutdown activates when the scanner is left idle, prolonging scanner life and conserving power integrated motion sensor "knows" when you are ready to use it
R44-1430
3
Page 6
MANUAL OVERVIEW International symbols are used throughout this manual to provide a simple visual indication of the information being discussed. In most cases, each topic's name is preceded by a simple graphic. For example is the internationally recognized symbol for a speaker. Appendix A, Symbol Definitions, shows all the symbols used in this manual and describes their meaning. These symbols come from the International Electrotechnical Commission (IEC) Publication 417G, Graphical Symbols for Use on Equipment.
OPERATIONAL OVERVIEW The scanner has three operational states: Normal Mode, Sleep Mode and Programming Mode.
NORMAL MODE Normal Mode is the scanner state when it reads barcodes and sends label data to the host. When the scanner is idle in Normal Mode for a prolonged period of time, it transitions into Sleep Mode to conserve power and prolong scanner life.
SLEEP MODE Sleep Mode is the term used to describe the scanner's condition after the motor and/or laser have automatically switched off due to a prolonged period of inactivity.
PROGRAMMING MODE Entering Programing Mode allows you to change scanner features such as the speaker volume, scanner to host interface parameters, barcode symbologies, and laser and motor time-outs. When the scanner is in Programming Mode, you cannot scan normal barcodes and the scanner will not send data to the host. A Programming Kit for the HS1250 is available from PSC or your dealer or distributor. Ask for part number R44-1340.
4
HS1250 User's Guide
Page 7
CONTROLS & INDICATORS The descriptions on the following pages detail the function of the controls and indicators for the HS1250. Note that two of these items, the speaker and volume switch, are located beneath the scanner's top cover.
VOLUME SWITCH While the scanner is in Normal Mode and the green lamp is on dim, you can easily change the volume on the HS1250 scanner by pressing the switch. The scanner has three volume settings available. When you press the switch, the scanner sounds a tone three times at the new volume setting. Each time you press the switch, the scanner sounds the next highest volume until it reaches the highest volume. After reaching the highest volume, pressing the switch again will return the volume to the lowest level. When the scanner is turned off, the volume setting you selected using the switch will be lost. To change the volume permanently, use the Volume Selection labels in the Programming Kit (R44-1340).
R44-1430
5
Page 8
INDICATORS INDICATOR LAMP The indicator lamp has six active modes; off, on dim, flash once, flashing continually once per second, flashing continually twice per second and repeating a series of flashes. Off indicates that either there is no power to the scanner or the scanner is not operational. On dim shows that the scanner is on and ready for operation. This is the normal operating condition. Flashes once brightly when the scanner has read a barcode label. This is accompanied by a good read tone from the speaker unless the speaker has been turned off using programming labels. Flashing once per second indicates the scanner has automatically shutdown due to a prolonged period of inactivity. This condition is referred to as "Sleep Mode" which extends the life of scanner components by removing power from the laser diode and motor when the scanner is not in use. The length of time that the scanner waits before going into Sleep Mode can be changed using the programming labels contained in the HS1250/VS1200 Programming Kit (P/N R44-1340). Flashing twice a second indicates that the scanner is in Programming Mode. The scanner will not read regular barcode labels or send data to the host when in this mode. Flashes repeatedly accompanied by a repeated series of tones indicates a scanner failure has occurred.
6
HS1250 User's Guide
Page 9
SPEAKER The speaker produces an audible indication of scanner operation. It sounds a normal tone, an alternate tone, or an error tone (a repeating series of tones). NORMAL TONE The normal tone sounds when a barcode label is recognized, its content is decoded and the data is transmitted to the host. ALTERNATE TONE The alternate tone has a lower pitch than the normal tone. It is sounded in four different situations: •
• •
In Normal Mode when the barcode has been read but the scanner is not programmed to transmit that symbology to the host. In Normal Mode when the HS1250 cannot successfully decode a barcode label. When in Programming Mode, any programming label that your scanner cannot use (e.g. Baud Rate for any interface other than RS-232) is rejected and the alternate tone is sounded.
ERROR TONE The error tone alerts the operator of possible system or component failure and only sounds when a problem is detected. Number of Tones
Failed Components
1
Digital Board
2
VLD (Visible Laser Diode) Module
3
Motor
4
Digital Board
7
VLD (End of life)
R44-1430