Page 5

Introduction The HS1250 is a compact high-performance horizontal scanner. Slide-through scanning enhances productivity and throughput, while eliminating the need to lift items being scanned. This Quick Reference Guide describes: • scanning with the HS1250

• the controls and indicators

• where to find additional information

In addition to this guide, a CD is packaged with the scanner that contains portable document format (PDF) copies of the User’s Guide and Programming Guide. These manuals are also available for download from the PSC website (www.pscnet.com). Print manuals may be ordered from your PSC representative (see back cover for contact information).

Operation The scanner’s Read Zone extends approximately 6" (15.24 cm) above the window, angled at approximately 40° from the counter and expands as you move away from the scanner's window.

Read Zone

40˚

When the bar code is swept through the Read Zone, the scanner immediately reads the label, successfully completing the scanning operation. To obtain optimum scanner performance, face the bar code toward the scanner and sweep it over the scan window. Refer to the arrow on the scanner's top, which indicates product flow direction.

Quick Reference Guide

1

Page 6

Controls & Indicators The scanner has a volume switch, speaker and indicator light. Note that two of these items, the speaker and volume switch, are located beneath the scanner’s top cover.

Volume Switch The scanner has three volume settings. When you press the switch or scan this label, the scanner sounds a tone three times at the new setting. Each time you press the switch or scan the label, the scanner sounds the next highest volume until it reaches the highest volume. After reaching the highest volume, pressing the switch again will return the volume to the lowest level.

Increment Volume

This volume setting will be lost when the scanner is turned off. Use the programming bar codes found in the Programming Guide for this product to permanently change the volume. The Manuals CD contains a copy of this programming Guide.

2

HS1250 Scanner

Page 7

Indicator lamp Lamp Activity

Indication

Off

No power or scanner is not operational

On dim

Scanner is on and ready for operation.

Flashes once

Occurs when a bar code is read. Accompanied by good read tone from the speaker (if on)

Flashes once per second

Scanner has automatically gone into “Sleep Mode”.

Flashes twice per second

Scanner is in Programming Mode; will not read or send data to the host

Flashes repeatedly

Along with repeated tones, indicates scanner failure

Speaker The speaker produces an audible indication of scanner operation. It sounds a normal tone, an alternate tone, or error tones (a repeating series of tones). •

Normal Tone - sounds when a bar code label is successfully decoded and transmitted to the host.

•

Alternate Tone - has a lower pitch than the normal tone. It sounds in Normal Mode if the scanner cannot successfully read a bar code label or reads a bar code but is not programmed to transmit that symbology to the host. It sounds in Programming Mode when a programming label is rejected because the scanner cannot use that feature (e.g. trying to set Baud Rate for any interface other than RS-232).

•

Error Tones - alert the operator when a problem is detected. See the User’s Guide for details.