The text of a manual · part 5 of 19
Falcon DOS Portable Data Terminals Advanced User's Guide, pages 41 to 50
Pages 41 to 50 of 184
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic F330 and PSC F330
Page 41
advuser.book Page 13 Friday, September 27, 2002 4:22 PM
Using the Falcon Configuration Utility
2.
An Open dialog box appears.
3.
Use the Open dialog box to choose a configuration file from the Configs folder.
4.
If Browse is selected after making changes in this or any other File Configuration window and the changes are not saved, the prompt shown in Figure 2-5 on page 2-8 appears.
Add a 2nd VDISK: Select to add a 2nd VDISK in the extended memory area on the Falcon. (Refer to page 1-10.) Select Size: Use this drop down list box to select the size of the 2nd disk. ATA Memory Cards: Turn this switch on to transfer drivers for ATA memory cards to the Falcon. I/O Cards: Turn this switch on to transfer drivers for fax/modem cards to the
Falcon. Vendor Specific: Turn this switch on to transfer drivers for other types of PC cards. This option loads PC Card drivers for Card and Socket Services only. Generic client drivers such as ATA or I/O Card drivers are not loaded if this is the only card switch turned on. Use this for RF cards that have their own specific client drivers that will be loaded using application files in the first file configuration window. (refer to page 2-9) DOS Files: Turn this switch on to transfer files for DOS commands and utilities to the Falcon.
More Select More to add or remove DOS files from the custom installation. The Select DOS Files dialog box appears (Figure 2-11 on page 2-14). Highlight DOS files to download to portable: This field lists DOS files that are available. Files that are highlighted are currently selected to be included in the custom installation. Click on a file to select it or deselect it.
Advanced User’s Guide
2-13
Page 42
advuser.book Page 14 Friday, September 27, 2002 4:22 PM
The Falcon Configuration Utility Figure 2-11: The Select DOS Files Dialog Box
Directory on portable to store DOS files: Use this field to specify where the DOS files should be placed in the Falcon unit.
Done Select Done to return to the File Configuration window. Select Product: Select the appropriate radio-button for type the Falcon model being configured: 31x, 32x/33x/34x, or 51x.
Prev Select Prev to return to the previous file-configuration window. Next Select Next to move on to the next file-configuration window. The third File Configuration window (Figure 2-12) appears if Next is selected in the second window.
2-14
Falcon® DOS Portable Terminals
Page 43
advuser.book Page 15 Friday, September 27, 2002 4:22 PM
Using the Falcon Configuration Utility
Done Select Done when finished setting file-configuration options for the custom installation. Figure 2-12: The Third File Configuration Window
Configuration File: This field shows the configuration file used to specify the files that will be loaded into the Falcon.
Save After selecting options in this window, select Save to save the revisions in the current configuration file or in a new one. Browse
1.
Select Browse to use a different configuration file.
2.
An Open dialog box appears.
3.
Use the Open dialog box to choose a configuration file from the Configs folder.
Advanced User’s Guide
2-15
Page 44
advuser.book Page 16 Friday, September 27, 2002 4:22 PM
The Falcon Configuration Utility
4.
If Browse is selected after making changes in this or any other File Configuration window and the changes are not saved, the prompt shown in Figure 2-5 on page 2-8 appears.
AUTOEXEC.BAT: Select this option to insert new commands into the autoexec.bat file that will be transferred to the Falcon. CONFIG.SYS: Select this option to insert new commands into the config.sys file that will be transferred to the Falcon. Text File: Select this option to view or modify any text file that will be transferred to the Falcon. Select Product: Select the appropriate radio-button for type the Falcon model being configured: 31x, 32x/33x/34x, or 51x.
Prev Select Prev to return to the previous file-configuration window. Done Select Done when finished setting file-configuration options for the custom installation.
The Program Settings Windows 1.
Select the Program Settings from the Custom Configuration Menu and the first of six Program Settings windows appears.
2.
Use these windows to view or change settings for bar code symbologies and other programmable options. z The first window is shown in Figure 2-13 on page 2-17. z The next four windows are similar, and so are not shown.
Program Settings File: This field shows the program-settings file that will be loaded into the Falcon. Save After selecting options in this window, select Save to save the revisions in the current program-settings file or in a new one. Browse
2-16
1.
Select Browse to use a different program settings file.
2.
The Open dialog box appears.
Falcon® DOS Portable Terminals
Page 45
advuser.book Page 17 Friday, September 27, 2002 4:22 PM
Using the Falcon Configuration Utility
3.
Use the dialog box to choose a configuration file from the Progsets folder.
Figure 2-13: The First Program Settings Window
4.
If Browse is selected after making changes in this or any other Program Settings window and the changes are not saved, the prompt shown in Figure 2-6 on page 2-8 appears.
On/Off Switches: The smaller white boxes are on/off switches. Click in the box to toggle a switch. Input Fields: Enter specific settings for parameters in the larger white boxes.
(Refer to Appendix C for a table of parameters and settings.) Select Product: Select the appropriate radio-button for type the Falcon model being configured: 31x, 32x/33x/34x, or 51x.
Advanced User’s Guide
2-17
Page 46
advuser.book Page 18 Friday, September 27, 2002 4:22 PM
The Falcon Configuration Utility
Prev Select Prev to return to the previous program-settings window. Next Select Next to move on to the next program-settings window. Done
1.
Select Done when finished making program settings for the custom installation.
2.
The sixth Program Settings window (Figure 2-14) appears if Next is selected in the fifth window.
Figure 2-14: The Sixth Program Settings Window
Program Settings File: This field shows the program-settings file that will be loaded into the Falcon. Save After selecting options in this window, select Save to save the revisions in the current program-settings file or in a new one. Browse 2-18
1.
Select Browse to use a different program settings file.
Falcon® DOS Portable Terminals
Page 47
advuser.book Page 19 Friday, September 27, 2002 4:22 PM
Using the Falcon Configuration Utility
2.
The Open dialog box appears.
Figure 2-15: The Last Program Settings Window
3.
Use the Open dialog box to choose a configuration file from the Progsets folder.
4.
If Browse is selected after making changes in this or any other File Configuration window and the changes are not saved, the prompt shown in Figure 2-6 on page 2-8 appears.
Spotting Beam Enable: Select to enable the Spotting Beam. This feature is reviewed in the Falcon DOS Portable Data Terminal User’s Guide on page 58. On/Off Switches: The smaller white boxes are on/off switches. Click in the box to toggle a switch.
Advanced User’s Guide
2-19
Page 48
advuser.book Page 20 Friday, September 27, 2002 4:22 PM
The Falcon Configuration Utility Input Fields: Enter specific settings for parameters in the larger white boxes.
(Refer to page C-3 for a table of parameters and settings.) Double Action Key Mode: Select Double Strike or Press and Wait as the Double Action Key Mode. Both selections in the Falcon DOS Portable Terminals User’s Guide on page 38. Double Action Key Delay: Select Double Action Key delay. This feature is reviewed in the Falcon DOS Portable Terminals User’s Guide on page 38. Drop-Down Lists: Click on the list to view the options, and select the desired option. Radio Buttons: Select the desired setting by clicking on it.
Prev Select Prev to return to the previous program-settings window. Done Select Done when finished making program settings for the custom installation.
The Comm Settings Dialog Box
2-20
1.
Select Comm Settings from the main menu or the Custom Configuration menu.
2.
The Comm Settings dialog box (Figure 2-16 on page 2-21) appears.
3.
Use this dialog box to view or change settings for serial communications with the Falcon.
Falcon® DOS Portable Terminals
Page 49
advuser.book Page 21 Friday, September 27, 2002 4:22 PM
Using the Falcon Configuration Utility Figure 2-16: The Comm Settings Dialog Box
Comm Port: Select the desired serial port for the PC to communicate with the
Falcon. The default port is COM1. Baud Rate: Select the baud rate for serial communications between the PC and the Falcon. The default is 9600.
The File Transfer Window 1.
When selecting Transfer Files from the main menu, the File Transfer window appears (Figure 2-18 on page 2-22).
2.
Use this window to select data files for transfer between the Falcon and the computer.
List File: This field shows the name of the file-list file, when selected.
Transfer files can be selected without using or creating a list file.\
Save After making changes in the Files to Transfer list, select Save to save the revisions in the current file-list file (if any), in another existing file, or in a new file. Browse
1.
Select Browse to use a different file-list file.
2.
An Open dialog box appears.
Advanced User’s Guide
2-21
Page 50
advuser.book Page 22 Friday, September 27, 2002 4:22 PM
The Falcon Configuration Utility Figure 2-17: The File Transfer Window
3.
Use the dialog box to choose a configuration file from the Filelist folder.
4.
If Browse is selected after making changes in this or any other File Transfer window and the changes are not saved, the following prompt appears:
Figure 2-18: The Prompt for Saving Changes to the Current File List
Yes 2-22
1.
Select this option to save the changes.
Falcon® DOS Portable Terminals