The text of a manual · part 10 of 11
Installation and Operation Manual, LazerData Series 9000E Barcode Scanner/Decoder, pages 91 to 100
Pages 91 to 100 of 104
The original document is the PDF (714 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC 9000 and Datalogic 9000
Page 91
HOST PROGRAMMING
COMMAND
FUNCTION
GLEVHIGH GLEVLOW
Gate Level high Gate Level low Example: >:GLEVHIGH<enter>
Gate input is active high. COMMAND
FUNCTION
GRLOGALL GRLOGFIRST GRLOGANY
Good Read logic all fields Good Read logic first field Good Read logic any field Example: >:GRLOGALL<enter>
Every code type for each field must be identified for a Good Read Pulse.
6-13
Page 92
Series 9000E Bar Code Scanner/Decoder COMMAND
FUNCTION
XNCON XNCOFF VER SHOGATE SHOHOST SHOLOCAL SHOIO SHODIAG SHOCMP SHOFLD1 SHOFLD2 SHOFLD3 SHOFLD4 SHOFLD5 SHOFLD6 SHOALL
Transmit NoCompare on NoRead on Transmit NoCompare on NoRead off Shows software version Shows all settings for menu page 1 Shows all settings for menu page 3 Shows all settings for menu page 4 Shows all settings for menu page 5 Shows all settings for menu page 7 Shows all settings for menu page 8 Shows all settings for menu field 1 Shows all settings for menu field 2 Shows all settings for menu field 3 Shows all settings for menu field 4 Shows all settings for menu field 5 Shows all settings for menu field 6 Dumps all the configuration setting out host port Example: >:VER<enter>
Shows software version currently running. COMMAND
FUNCTION
SAV LDF
Save settings Loads and saves Default configuration and automatically EXITS Host Commands Example: >:SAV<enter>
Saves changes made in setup.
6-14
Page 93
HOST PROGRAMMING
COMMAND
FUNCTION
EXIT
Exit Host Commands Example: >:EXIT<enter>
Exits Host Commands mode. COMMAND
FUNCTION
ENB
Enable
6-15
Page 94
Series 9000E Bar Code Scanner/Decoder OPTIONS TO ENABLE FLD (1-6) LINE (1-10) CODE TYPE:
SS CD LEN RDC HGRT xx HNRT xx HRCT xx LGRT xx LNRT xx LRCT xx LMS
C39 UPCA UPCE I25 C128 EA13 EAN8
CDBR C93 C49 AS10 BINY C11 SUPP5
PHRM ISTR SUPP2
Start/Stop transmit (on) Check Digit transmit (on) Set Length (0-60) Set Read Count (0-99) Host Good Read text (blank spaces must be entered as <SP>) Host No Read text (blank spaces must be entered as <SP>) Host Read Conflict text (blank spaces must be entered as <SP>) Local Good Read text (blank spaces must be entered as <SP>) Local No Read text (blank spaces must be entered as <SP>) Local Read Conflict text (blank spaces must be entered as <SP>) Label Mask String (on)
Example: >:ENB FLD # LINE # CODE TYPE SS CD LEN# RDC##<enter> Example: >:ENB FLD 1 LINE 1 I25<enter> Inserts Interleaved 2 of 5 in first field. When enabling a code type the FLD and LINE number must be specified.
6-16
Page 95
HOST PROGRAMMING
SS will enable start/stop character transmission for the specified field and line. CD will enable check digit transmission for the specified field and line. LEN will default to 0 if not specified. RDC will default to 0 if not specified. Example: >:ENB FLD # HGRT xx<enter> Note: xx is text to insert When enabling a text string the FLD (1-6) must be given. Example: >:ENB FLD # LINE # LMS CODE TYPE TEXT STRING<enter> When enabling the Label Mask String the FLD (1-6) and the LINE (1-5) must be given. Code Type must be specified, followed by the text string.
6-17
Page 96
Series 9000E Bar Code Scanner/Decoder COMMAND
FUNCTION
DSB
Disable
OPTIONS TO DISABLE FLD (1-6) LINE (1-10) CODE SS CD LEN RDC HGRT HNRT HRCT LGRT LNRT LRCT LMS
Disables any code type Start/Stop transmit (off) Check Digit transmit (off) Set Length (0) Set Read Count (0) Host Good Read text Host No Read text Host Read Conflict text Local Good Read text Local No Read text Local Resd Conflict text Label Mask String (off)
Example: >:DSB FLD # LINE # CODE SS CD LEN RDC<enter> When disabling a code type the FLD and LINE number must be specified. If they are not, they will default to FLD 1 LINE 1.
6-18
Page 97
HOST PROGRAMMING
SS will disable start/stop character transmission for the specified field and line. CD will disable check digit transmission for the specified field and line. LEN will be set to 0 for the specified field and line. RDC will be set to 0 for the specified field and line.
When disabling a text string the FLD (1-6) must be given. The text string will be set back to the factory default setting when disabled. Example: >:DSB FLD # HGRT<enter> When disabling the Label Mask String the FLD (1-6) and the LINE (1-5) must be given. Code Type will be set to off and the string will be set to null. Example: >:DSB FLD # LINE # LMS<enter> LMS master switch will only turn off when Line 1 of the masks are disabled. Otherwise it must stay enabled to check the other lines.
6-19
Page 98
Series 9000E Bar Code Scanner/Decoder
6-20
Page 99
APPENDIX
GLOSSARY OF TERMS
Alphanumeric Display - A display that presents the alphabetic characters A thru Z as well as the numbers 0 thru 9. Bar Code - An array of rectangular marks and spaces in a predetermined pattern. Bar Code Character - A single group of bars and spaces which represent an individual number, letter, punctuation mark or other symbol. Baud - The signalling rate at which serial data transmissions are sent. It is the switching speed, or number of transitions (voltage or frequency changes) that are made per second. Only at low speeds are bauds equal bits per second; for example, 300 baud equals 300 bits per second equals 30 characters per second. Baud Rate - A redundant reference to baud, which is a rate. See Baud. Check Digit - A calculated character included in a barcode, that is used for error detection. Code Density - The number of characters per inch of length that the bar code symbol contains. Code Length - The number of characters contained in the bar code symbol. Does not include start or stop patterns. APPENDIX-1
Page 100
SERIES 9000E Decoder - A microprocessor based device that accepts a digital input signal from a scanner, decodes that signal, and transmits the barcoded data to another device. Depth of Field - The distance between the maximum and minimum plane from which a bar code symbol can be read. EAN - European Article Numbering System, the international standard bar code for retail food packages. EIA - Electronic Industries Association. Laser Diode - A semiconductor device that emits a highly concentrated beam of light. Misalignment - Misorientation of the code from its normal position. Non-Volatile Memory - Memory that will not lose its contents with an interruption of power. No Read - Inability to read a barcode because of a defective code symbol, missing code symbol, or decoder failure. Omni-Directional - A bar code reading system that can read a code regardless of orientation. Usually this type of scanner emits multiple scanning beams. Pitch - Misalignment of the bar code symbol around the xaxis.
APPENDIX-2