Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 3

PowerScan 7000 2D Imager Quick Reference Guide, pages 11 to 20

Pages 11 to 20 of 28

The original document is the PDF (714 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic 7000 (P70) and PSC 7000 (P70)

Page 11

LED and Beeper Indications

LED and Beeper Indications The imager is equipped with a beeper (speaker) and two indicator LEDs; one green and one yellow. These indicators “beep” or flash when certain actions take place:

NOTE

Some LED and Beeper indications are user-configurable for volume, pitch, quantity, duration, enable/disable, etc. Those listed in the following table assume the feature is enabled. See the Product Reference Guide (PRG) for detailed programming information.

Condition Powering On UKBW/RS-232 Models (using UKBW interface) Powering On UKBW/RS-232 Models (using RS-232 interface) Powering On All Other Models Good Read

Green LED

Beeper

2 normal flashes and 2 fast flashes (+ 1 normal flash with Smart cable)

One Beep

2 normal flashes and 1 long flash

One Beep

Bright Green Flash

One Beep

1 - 9 Bright Green Flash(es)a Green Flash

1 - 9 Beep(s)a Special Beep

Yellow LED

Beeper

Yellow LED on steady until trigger is pulled

None

Error Indication Condition Ready to Operate a. Good Read indications are synchronous. That is, if Good Read beeps are set via programming to five (for example), the Good Read LED will also flash five times.

Quick Reference Guide

3

Page 12

Plug and Play Plug and Play bar codes provide instant imager set up for commonly used interfaces. After you scan one of the codes, power cycle the host terminal to have the interface in effect. NOTE

Connecting the imager with an RS-232 Serial Port These instructions are for use with the RS-232 cable. This includes both Power Off the Terminal (P.O.T.) and external power. NOTE

1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the imager. For the imager to work properly, you must have the correct cable for your type of terminal/computer. NOTE

Cable Connector Retainer Boss

Captive Screws

4

For 220-230 VAC adapters, the cord must be facing down as shown in the illustration. If installed upwards, it will pose an undue strain on the socket outlet.

PowerScan® 7000 2D

Page 13

Plug and Play

3. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. 4. If the terminal does not support Power Off the Terminal (P.O.T.) connections plug the power supply into the host connector and the AC outlet. 5. Once the imager has been fully connected, power up the computer. All communication parameters between the imager and terminal must match for correct data transfer through the serial port using RS-232 protocol. Scanning the RS-232 interface bar code, programs the imager for an RS-232 interface at 115,200 baud, parity–none, 8 data bits, 1 stop bit, and adds a suffix of a CR LF.

RS-232 Interface

Connecting the imager with USB This interface applies to USB compatible models only. NOTE

An imager can be connected to the USB port of a computer. 1. Connect the appropriate interface cable to the imager and to the computer.

Captive Screws

B

Cable Connector Retainer Boss

US

Quick Reference Guide

5

Page 14

2. The imager beeps. 3. Verify imager operation by scanning the part number bar code from the back cover of this manual.

NOTE

The following USB “Plug and Play” codes are supported on specific models. Refer to the Product Reference Guide to determine if this interface applies to your unit.

For additional USB programming and technical information, visit the website listed on the back cover of this manual.

IBM SurePos Scan one of the following “Plug and Play” codes to program the imager for IBM SurePos (USB Hand Held imager) or IBM SurePos (USB Tabletop imager). After scanning one of these codes, you must power cycle the cash register NOTE

IBM SurePos (USB Hand Held imager) Interface IBM SurePos (USB Tabletop imager) Interface

6

PowerScan® 7000 2D

Page 15

Plug and Play

Each bar code above also programs the following suffixes for each symbology: Symbology EAN-8 EAN-13 UPC-A UPC-E Code 39 Interleaved 2 of 5 Code 128

NOTE

Suffix 0C 16 0D 0A 00 0A 0B 00 0D 0B 00 18 0B

The following USB “Plug and Play” codes (USB Keyboard - PC, USB Keyboard - Mac, and USB HID) are supported on specific imager models. Check your model type to determine if this interface applies to your unit.

USB PC Keyboard or USB Macintosh Keyboard Scan one of the following codes to program the imager for USB PC Keyboard or USB Macintosh Keyboard. Scanning these codes adds a CR and selects the terminal ID (USB PC Keyboard - 124, USB Macintosh Keyboard - 125).

USB Keyboard (PC) USB Keyboard (Mac)

Quick Reference Guide

7

Page 16

USB HID Scan the following code to program the imager for USB HID bar code imagers. Scanning this code changes the terminal ID to 131.

USB HID Bar Code imager

USB COM Port Emulation Scan the following code to program the imager to emulate a regular RS232-based COM port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the website listed on the back cover of this manual. The driver will use the next available COM port number. Apple® Macintosh computers recognize the imager as a USB CDC class device and automatically use a class driver. Scanning the code below changes the terminal ID to 130.

USB COM Port Emulation

No extra configuration (e.g., baud rate) is necessary. NOTE

CTS/RTS Emulation

On * Off

8

PowerScan® 7000 2D

Page 17

Plug and Play

ACK/NAK Mode

On * Off

Reference the Product Reference Guide (PRG) for more information about keyboard support. NOTE

Connecting the imager in Universal Keyboard Wedge mode The Universal Keyboard Wedge (UKBW) model allows an RS-232 transmission or Keyboard Wedge mode according to the type of cable connected. Contact Datalogic or your dealer for cable and/or power supply part numbers. 1. Turn off power to the terminal/computer. 2. Connect the keyboard wedge interface cable to the imager. For the imager to work properly, you must have the correct cable for your type of terminal/computer. NOTE

Quick Reference Guide

9

Page 18

3. Connect one end of the Y cable to the keyboard cable and the other to the keyboard port on the host/computer.

Cable Connector Retainer Boss K ey

Captive Screws bo ard

4. Scan the following bar code to program the imager for the UKBW interface.

~ p Universal a p 2 Keyboard 3 2 ; Wedge 2 3 (UKBW) 2 C T Interface S 1 ³

.

Configuring Parameters Configurable options are available for each interface type, which can be set using the Product Reference Guide (download from the website listed on the back cover of this manual). UKBW parameters are available exclusively in the Universal Keyboard Wedge Programming Guide, using the programming feature set provided for “PowerScan” models. This manual can also be downloaded from that website.

10

PowerScan® 7000 2D

Page 19

Resetting the Standard Product Defaults

Resetting the Standard Product Defaults If programming settings for your scanner are in an unknown condition, factory settings can be restored by scanning the “Standard Product Default Settings” bar code below. A listing of factory default settings is available in the PRG. Settings can vary, depending upon the interface type.

Standard Product Default Settings

Repairs Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center. See the Product Reference Guide for further information.

Maintenance The imager provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable imager operation:

Cleaning the Imager’s Window Reading performance may degrade if the imager’s window is not clean. If the window is visibly dirty, or if the imager isn’t operating well, clean the window with a soft cloth or lens tissue dampened with water (or a mild detergent- water solution). If a detergent solution is used, rinse with a clean lens tissue dampened with water only.

Quick Reference Guide

11

Page 20

The imager’s housing may also be cleaned the same way.

CAUTION

Do not submerge the imager in water. Do not use abrasive wipes or tissues on the imager’s window – abrasive wipes may scratch the window. Never use solvents (e.g., acetone, benzene, ether, or phenol-based agents) on the housing or window – solvents may damage the finish or the window.

Inspecting Cords and Connectors Inspect the imager’s interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with imager operation. Contact your dealer for information about cable replacement. Cable replacement instructions are included below.

Troubleshooting The imager automatically performs self-tests whenever you turn it on. If your imager is not functioning properly, review the following Troubleshooting Guide to try to isolate the problem. •

Is the power on? Is the green aiming illumination line on?

If the green aiming illumination line isn’t illuminated, check that: •

The cable is connected properly.

•

The host system power is on (if external power isn’t used).

•

The trigger works.

Is the imager having trouble reading your symbols? If the imager isn’t reading symbols well, check that the symbols: •

Aren’t smeared, rough, scratched, or exhibiting voids.

•

Aren’t coated with frost or water droplets on the surface.

12

PowerScan® 7000 2D