For the Datalogic 7000 (P70) and PSC 7000 (P70)

Page 69

Chapter 6

Symbologies This programming section contains the following menu selections. Refer to Chapter 10 for settings and defaults. ·Linear Symbologies

·Japanese Post

·Australian Post

·Kix (Netherlands) Post

·Aztec Code Enable

·Korea Post

·British Post

·Matrix 2 of 5 Enable

·Canadian Post

·MaxiCode Enable

·China Post Enable

·MicroPDF417 Enable

·Codabar Enable

·MSI Enable

·Codablock F Enable

·PDF417 Enable

·Code 11 Enable

·Planet Code

·Code 128 Enable

·Plessey Code Enable

·Code 16K Enable

·PosiCode A and B Enable

·Code 2 of 5 Enable

·Postnet

·Code 39 Enable

·QR Code

·Code 49 Enable

·Micro QR Code

·Code 93 Enable

·RSS Expanded Enable

·Data Matrix Enable

·RSS Limited Enable

·EAN/JAN-13 Enable

·RSS-14 Enable

·EAN/JAN-8 Enable

·TCIF Linked Code 39 (TLC39)

·EAN•UCC Composite Codes

·Telepen

·IATA Code 2 of 5 Enable

·UPC-A Enable

·Interleaved 2 of 5 Enable

·UPC-A/EAN-13 with Extended Coupon Code

Product Reference Guide

6-1

Page 70

Symbologies

Linear Symbologies All Symbologies If you want to decode all the symbologies allowable for your imager, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On symbol for that particular symbology.

All Symbologies On All Symbologies Off

Message Length Description You are able to set the valid reading length of some of the bar code symbologies. If the data length of the scanned bar code doesn’t match the valid reading length, the imager will issue an error beep. You may wish to set the same value for minimum and maximum length to force the imager to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes included in the explanation of the symbology, then scan the digit value of the message length and Save bar codes on the Programming Chart on page B-5 of this manual. The minimum and maximum lengths and the defaults are included with the respective symbologies.

6-2

PowerScan® 7000 2D

Page 71

Linear Symbologies Codabar <Default All Codabar Settings>

Codabar Enable

* On Off Codabar Start/Stop Characters

Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.

Transmit * Don’t Transmit Codabar Check Character

Codabar check characters are created using different “modulos.” You can program the imager to read only Codabar bar codes with Modulo 16 check characters. Default = No Check Character. No Check Character indicates that the imager reads and transmits bar code data with or without a check character. When Check Character is set to Validate and Transmit, the imager will only read Codabar bar codes printed with a check character, and will transmit this character at the end of the scanned data.

Product Reference Guide

6-3

Page 72

Symbologies

When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data.

* No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit Codabar Concatenation

Codabar supports symbol concatenation. When you enable concatenation, the imager looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted. Default = On. Character

Start

Stop

Start

Stop

Codabar A12D

D34A

Select Require to prevent the imager from decoding a single “D” Codabar symbol without its companion. This selection has no effect on Codabar symbols without Stop/Start D characters.

On * Off Require

6-4

PowerScan® 7000 2D

Page 73

Linear Symbologies Codabar Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60.

Minimum Message Length

Maximum Message Length

Code 39 < Default All Code 39 Settings >

Code 39 Enable

* On Off Code 39 Start/Stop Characters

Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.

Transmit * Don’t Transmit

Product Reference Guide

6-5

Page 74

Symbologies Code 39 Check Character No Check Character indicates that the imager reads and transmits bar code data with or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 bar codes printed with a check character, but will not transmit the check character with the scanned data. When Check Character is set to Validate and Transmit, the imager only reads Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Character.

* No Check Character Validate, but Don’t Transmit Validate and Transmit Code 39 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 0-48. Minimum Default = 0, Maximum Default = 48.

Minimum Message Length Maximum Message Length

6-6

PowerScan® 7000 2D

Page 75

Linear Symbologies Code 39 Append

This function allows the imager to append the data from several Code 39 bar codes together before transmitting them to the host computer. When this function is enabled, the imager stores those Code 39 bar codes that start with a space (excluding the start and stop symbols), and does not immediately transmit the data. The imager stores the data in the order in which the bar codes are read, deleting the first space from each. The imager transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space. Default = Off.

On * Off Code 32 Pharmaceutical (PARAF or Pharmacode)

Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as PARAF. Trioptic Code (page 6-33) must be turned off while scanning Code 32 Pharmaceutical codes. NOTE

On * Off

Product Reference Guide

6-7

Page 76

Symbologies Full ASCII

If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off. NUL %U

DLE $P

0

0

@

%V

P

P

‘

%W p

+P

DC1 $Q

SP SPACE ! /A

SOH $A STX $B

1

1

A

A

Q

Q a

+A q

+Q

DC2 $R

“

2

2

B

B

R

R b

+B r

+R +S

/B

ETX $C

DC3 $S

#

/C

3

3

C

C

S

S c

+C s

EOT $D

DC4 $T

$

/D

4

4

D

D

T

T d

+D t

+T

ENQ $E

NAK $U

%

/E

5

5

E

E

U

U e

+E u

+U

ACK $F

SYN $V

&

/F

6

6

F

F

V

V f

+F v

+V

BEL $G

ETB $W

‘

/G

7

7

G

G

W

W g

+G w

+W

BS

$H

CAN $X

(

/H

8

8

H

H

X

X h

+H x

+X

HT

$I

EM

$Y

)

/I

9

9

I

I

Y

Y i

+I y

+Y

LF

$J

SUB $Z

*

/J

:

/Z

J

J

Z

Z j

+J z

+Z

VT

$K

ESC %A

+

/K

;

%F

K

K

[

%K k

+K

{

%P

FF

$L

FS

%B

,

/L

<

%G L

L

\

%L l

+L

|

%Q

CR

$M

GS

%C

-

-

=

%H

M

M

]

%M m

+M

}

%R

SO

$N

RS

%D

.

.

>

%I

N

N

^

%N n

+N

~

%S

SI

$O

US

%E

/

/O

?

%J

O

O

_

%O o

+O

DEL %T

Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9.

Full ASCII On * Full ASCII Off

6-8

PowerScan® 7000 2D

Page 77

Linear Symbologies Code 39 Code Page

Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see Code Page Mapping of Printed Bar Codes on page A-7) and scan the value and the Save bar code from the Programming Chart on page B-5 of this manual. The data characters should then appear properly.

Code 39 Code Page

Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings >

Interleaved 2 of 5 Enable

* On

Off

Check Digit No Check Digit indicates that the imager reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.

Product Reference Guide

6-9

Page 78

Symbologies

When Check Digit is set to Validate and Transmit, the imager only reads Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit.

* No Check Digit Validate, but Don’t Transmit Validate and Transmit Interleaved 2 of 5 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80.

Minimum Message Length Maximum Message Length

6-10

PowerScan® 7000 2D