Page 79

Linear Symbologies

Code 93 < Default All Code 93 Settings >

Code 93 Enable

* On Off Code 93 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80.

Minimum Message Length Maximum Message Length Code 93 Code Page

Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see Code Page Mapping of Printed Bar Codes on page A-7) and scan the value and the Save bar code from the Programming Chart on page B-5 of this manual. The data characters should then appear properly.

Code 93 Code Page

Product Reference Guide

6-11

Page 80

Symbologies

Code 2 of 5 <Default All Code 2 of 5 Settings>

Code 2 of 5 Enable

On * Off Code 2 of 5 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.

Minimum Message Length Maximum Message Length

6-12

PowerScan® 7000 2D

Page 81

Linear Symbologies

IATA Code 2 of 5 <Default All Code IATA 2 of 5 Settings>

IATA Code 2 of 5 Enable

On * Off IATA Code 2 of 5 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.

Minimum Message Length Maximum Message Length

Product Reference Guide

6-13

Page 82

Symbologies

M atrix 2 o f 5 <Default All Matrix 2 of 5 Settings>

Matrix 2 of 5 Enable

On * Off Matrix 2 of 5 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.

Minimum Message Length Maximum Message Length

Code 11 <Default All Code 11 Settings>

Code 11 Enable

On * Off

6-14

PowerScan® 7000 2D

Page 83

Linear Symbologies Check Digits Required

This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits.

One Check Digit * Two Check Digits Code 11 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.

Minimum Message Length Maximum Message Length

Product Reference Guide

6-15

Page 84

Symbologies

Code 128 <Default All Code 128 Settings>

Code 128 Enable

* On Off ISBT 128 Concatenation

In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood information in a uniform manner. The use of ISBT formats requires a paid license. The ISBT 128 Application Specification describes 1) the critical data elements for labeling blood products, 2) the current recommendation to use Code 128 due to its high degree of security and its space-efficient design, 3) a variation of Code 128 that supports concatenation of neighboring symbols, and 4) the standard layout for bar codes on a blood product label. Use the bar codes below to turn concatenation on or off. Default =Off.

On * Off

6-16

PowerScan® 7000 2D

Page 85

Linear Symbologies Code 128 Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80.

Minimum Message Length Maximum Message Length Code 128 Code Page

Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created (see Code Page Mapping of Printed Bar Codes on page A-7) and scan the value and the Save bar code from the Programming Chart on page B-5 of this manual. The data characters should then appear properly.

Code 128 Code Page Telepen <Default All Telepen Settings>

Product Reference Guide

6-17

Page 86

Symbologies Telepen

On * Off Telepen Output

Using AIM Telepen Output, the imager reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the imager reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Default = AIM Telepen Output.

* AIM Telepen Output Original Telepen Output Telepen Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description on page 6-2 for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60.

Minimum Message Length Maximum Message Length

6-18

PowerScan® 7000 2D

Page 87

Linear Symbologies

UPC-A <Default All UPC-A Settings>

UPC-A Enable

* On Off UPC-A Check Digit Transmit

This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.

* On Off UPC-A Number System

The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On.

* On Off

Product Reference Guide

6-19

Page 88

Symbologies UPC-A Addenda

This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda.

2 Digit Addenda On * 2 Digit Addenda Off

5 Digit Addenda On * 5 Digit Addenda Off UPC-A Addenda Required

When Required is scanned, the imager will only read UPC-A bar codes that have addenda. You must then turn on a 2 or 5 digit addenda listed on page 6-20. Default = Not Required.

Required * Not Required UPC-A Addenda Separator

When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space. Default = On.

* On Off

6-20