The text of a manual · part 2 of 12
User's / Programming Guide, Handheld Laser Bar Code Scanners, Keyboard Wedge / Wand Emulation Interface, pages 7 to 13
Pages 7 to 13 of 84: Introduction; Unpacking
The original document is the PDF (680 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the PSC 5381
Page 7
Introduction Keyboard Wedge Mode As a keyboard wedge interface, the PSC scanner can be used with terminals provided by most of the major terminal manufacturers. In most cases, the PSC scanner is easily connected between the keyboard and display of the terminal. The use of Preamble/Postamble, embedded keyboard function codes or keyboard function records allow operation of the terminal without manual entry from the keyboard. In this mode of operations, the PSC scanner draws power from the terminal.
Serial Communications Mode The PSC scanner can be configured by the user for a serial communication output. In this mode, the scanner can be connected to any device that accepts serial ASCII data at TTL voltage levels. RS232 voltage levels can be achieved by the use of an optional RS232 conversion pod. AutoSense® Mode The PSC scanner may be configured at the factory with PSC’s AutoSense® feature. AutoSense® operates with a passive stand for hands-free operation. When the scanner is placed in the stand, it becomes immediately active for reading any bar code label presented to it. The user can remove the scanner from the AutoSense® Stand and use it as a conventional hand-held scanner. When replaced in the stand, the scanner reverts automatically to AutoSense®.
Wand Emulation Mode The PSC scanner can be configured by the user for Wand Emulation. In this mode, the PSC scanner can be connected to any device that accepts a wand signal input. Wand Emulation communication presents bar code data to a host device exactly as a wand does. This precludes the use of any option which adds information to the bar code symbol data (preamble, for example). A typical example of this would be to interface the scanner to a portable data terminal for remote data collection.
Magnetic Stripe Reader Magnetic stripe reading capabilities are available with appropriate cabling.
06656
1
Page 8
Unpacking Your package should include a scanner, interface cable, User’s Manual, and a plastic scanner holder. The unit should be inspected immediately upon receipt to determine if any damage has occurred during shipment. If damage has occurred, a claim should be filed with the carrier immediately. Retain the shipping box, since it should be used to return the scanner to the factory for service.
Installation Keyboard Wedge In Keyboard Wedge mode the PSC scanner simulates keyboard keystrokes. Whether a person has pressed a key on the keyboard or data has been transmitted from the scanner is indistinguishable by the host device. When the PSC scanner is not transmitting data to the terminal the keyboard operates as if the PSC scanner was not attached. Installation of the PSC scanner should be completed by a user who is familiar with installing computer systems and cabling.
Cable Installation
2
1.
Turn off power to the terminal to which the PSC scanner will be connected.
2.
Verify that you received the correct cabling. The cable supplied for keyboard wedge installation is referred to as a “Y” cable.
3.
Connect the modular plug to the PSC scanner. Insert plug into the rectangular opening in the bottom of the scanner handle.
4.
Unplug the keyboard from the terminal and replug the keyboard into the short leg of the “Y” cable that mates with it.
5.
Plug the remaining long leg of the “Y” cable into the terminal where the keyboard was connected.
6.
Arrange the fully connected unit so that all cables run freely.
User’s / Programming Guide
Page 9
Connecting the Power Supply If supplied, plug the connector from the external power supply into the receptacle located on the housing connector. Then plug the power supply into a power source.
Connecting a Magnetic Stripe Reader If a detached Magnetic Stripe Reader (MSR) is to be used, plug the connector into the MSR receptacle located on the housing connector.
Terminal Power-Up Sequence Turn on the power to the terminal to which the PSC scanner is connected. The unit will issue a series of beeps which are intentional and indicate that the terminal/keyboard power-on reset routines have been completed. Programming for Terminal Type
NOTE
If this is a first-time installation, it is NECESSARY to program the PSC scanner for use with the connected terminal.
Proceed as follows: 1.
Using the Keyboard Wedge Parameters menu given in the Keyboard Wedge Parameters Section scan: WEDGE MODE ENABLE (CE) This sets the PSC scanner into a Keyboard Wedge interface mode.
2.
NOTE
06656
Select the terminal type by next scanning the appropriate symbol for your terminal. Scanning Reset to Default (ZA) will cause the PSC scanner to revert to Keyboard Wedge mode with a PC-AT terminal type.
3
Page 10
Serial Communications The PSC scanner provides the user with two different serial communications options: Serial TTL and Serial RS232 communications.
Serial TTL Mode Serial TTL is a serial communications interface that uses TTL/CMOS voltage levels ranging from 0 to 5 volts. The user can select a normally high (default setting) or normally low (inverted) voltage levels. Serial TTL communications mode uses different cables than those used in keyboard wedge applications. To configure the PSC scanner in a Serial TTL mode, the user must have the appropriate cable with the correct signal pinouts in order to interface the scanner to the host terminal. To program the PSC for Serial TTL communications, the user must first identify the serial communications parameters supported by the host terminal. Typical parameters are the baud rate, parity and number of bits in the data word. These parameters are discussed in the section on Serial Communication Parameters. The PSC scanner has the added versatility to enable the user to select the quiescent voltage levels for interfacing with terminals that require inverted signals.
Serial RS232 Mode The PSC scanner can also be used in an RS232 environment by converting the serial TTL voltage levels to RS232 voltage levels. For this installation, the user needs an optional cable, an adapter pod, and a power supply. When the PSC scanner is operated with the RS232 adapter pod, the same serial communications parameters apply as those used in a serial TTL environment. The only difference is that the RS232 adapter pod inverts the polarity of all the signals passing through it. Therefore, the user needs to program the scanner for serial communication, normal polarity (symbol CA). RS232 levels are available only in full continuous power mode.
4
User’s / Programming Guide
Page 11
AutoSense® Operation AutoSense® is a factory installed feature requested at time of order. It provides for hands-free or handheld operation. AutoSense® is activated by scanning the Enable AutoSense® symbol. The scanner will respond by emitting a continuous, low level red beam of light known as the trigger beam. AutoSense® is deactivated by scanning the Disable AutoSense® symbol. When the AutoSense® feature is used with PSC’s AutoSense® stand (specifically designed for standard and HP scanners), the user must first attach the plastic scanner holder to the bracket of the stand as shown in Figure 1, next page. The scanner is then mounted into the holder. Insure that the trigger beam is aimed at the reflective tape affixed to the stand. AutoSense® is now ready to automatically scan bar code labels presented to it. When the trigger beam is broken by the bar code label, the scan beam will automatically engage and decode the bar code symbol. Any time the scan beam disappears, whether by a decode or by a scan beam timeout, the automatic trigger must be re-enabled by allowing the trigger beam to sense the reflective tape. While AutoSense® is activated, the user is able to remove the scanner from its holder and use it for handheld scanning operation. When the scanner is removed from the AutoSense® holder, the trigger beam will be broken and the scan beam will automatically be engaged. If the scanner does not decode a bar code symbol, the scanning beam will turn off after two to six seconds. Scanning is re-initiated by manually pulling the trigger. When the scanner is replaced into the holder AutoSense® will be automatically re-engaged when the trigger beam senses the reflective tape.
NOTE
06656
When the scanner is powered from a battery, such as in a hand-held terminal, AutoSense® should be disabled. In a battery powered application, the user is strongly recommended to use the power conservation feature of scanner operation. Power conservation reduces power draw from the battery between scans to extremely low levels. AutoSense® will function only in full power mode.
5
Page 12
NO
Enable AutoSense®
NN
Disable AutoSense®
To use this mode of operation properly, the user must first attach the plastic scanner holder to the bracket of the stand as shown in Figure 1. The (NO) Enable AutoSense® programming symbol is scanned until the green “Good Decode” light blinks. This will activate the trigger screen. The scanner is then placed into the holder and the user must check that the red laser beam is aimed at the reflective label affixed to the stand. The AutoSense® is now ready to read labels presented to it. Figure 1. The PSC AutoSense® Stand a. b. c.
6
Riser sub-assembly Scanner holder Scanner d. e.
Reflective tape Stand base
User’s / Programming Guide
Page 13
Wand Emulation Operation To operate the PSC scanner in Wand Emulation the user must first turn off the powerto the host device and then detach the scanner from the host device by removing the cable from the scanner. The proper Wand Emulation cable must be connected between the scanner and the portable data terminal for remote data collection. If using an optional Smart Cable, the scanner automatically switches to Wand Emulation. Specific Wand Emulation parameters may still need to be set. If using a cable without Smart Cable switching, the user must then configure the scanner to its Wand Emulation mode by scanning the symbol CC.
CC
Same Code Wand Emulation
This symbol activates the following default parameters: Code Type = Same Code Wand Emulation Code type, bar code polarity, and transmission rate can each be set for Wand Emulation. Menu symbols for these parameters are found in the section on Wand Emulation Parameters. When the user with a Smart Cable again connects to the host device, the scanner will automatically revert to the original communication mode. Without Smart Cable, scan the appropriate programming symbol. CE
Enable Wedge
CA
Enable Serial Mode
06656
7