Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 26

ORiNOCO AP-700 User Guide: Installation and Initialization, pages 19 to 25

Pages 19 to 25 of 231, from ORiNOCO AP-700 User Guide

The original document is the PDF (4.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Proxim AP-700

Page 19

Installation and Initialization Hardware Installation •

AP-700 User Guide

Use a cross-over Ethernet cable or adapter if you intend to connect the unit to a single computer.

3. Optionally, connect an RS-232 cable (not shown) to the RS-232 console port (the right port, labeled “RS-232”). NOTE: You cannot install the security cover to the AP-700 if an RS-232 cable is connected. 4. Continue with Install the Security Cover (Optional). Cabling with Power Over Ethernet (PoE) 1. To use PoE, you must use a PoE adapter such as the ORiNOCO 1-Port Active Ethernet DC Injector (ordered separately). Connect one end of an Ethernet cable (not supplied) to the unit’s LAN port. Connect the other end to the Data and Power Out port of the DC Injector (see figure). 2. Connect one end of a second Ethernet cable (not supplied) to the Data In port of the DC Injector (see figure). The other end of the cable should not be connected to another device until after installation is complete: •

Use a straight-through Ethernet cable if you intend to connect the unit to a switch, hub, or patch panel.

•

Use a cross-over Ethernet cable or adapter if you intend to connect the unit to a single computer.

3. Optionally, connect an RS-232 cable (not shown) to the RS-232 console port (the right port, labeled “RS-232”). NOTE: You cannot install the security cover to the AP-700 if an RS-232 cable is connected. 4. Continue with Install the Security Cover (Optional) below.

Install the Security Cover (Optional) You can optionally install a security cover to deter unauthorized access to the unit. The security cover is a plastic enclosure that prevents access to the cabling and the Reset and Reload buttons. 1. Open the split end of the security cover just enough to slide the power cable (if not using PoE) and the Ethernet cable through the opening until they fit inside the straight clamping portion of the cover (see figure). Exercise care as you slide the cable(s) so you do not accidentally break the cover. 19

Page 20

Installation and Initialization Hardware Installation

AP-700 User Guide

2. Slide the hinging end of the security cover into the hole on the rear panel of the unit to the left of the connectors. Once in place, pivot the right side of the cover to bring it close to the rear panel of the unit. 3. Use the two attached screws to fasten the security cover onto the rear panel of the unit.

Mount the AP-700 Proxim recommends that you have a site survey professionally conducted to determine the best location for the AP. For professional site surveyors, Ekahau Site Survey software is included in the Xtras folder on the Installation CD-ROM. Note that the AP-700 has been certified under UL Standard 2043 and can be installed in the plenum. In an office building, plenum is the space between the structural ceiling and the tile ceiling that is provided to help air circulate. Many companies also use the plenum to house communication equipment and cables. These products and cables must comply with certain safety requirements, such as Underwriter Labs (UL) Standard 2043: “Standard for Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces”. NOTE: When installed in a plenum, the AP must use PoE. Once you have chosen a final location for your unit, the following are the mounting options are available: •

Wall Mounting

•

Ceiling Mounting

Wall Mounting Follow these steps to mount the unit on a wall: 1. If the unit’s power supply is plugged in, unplug it. 2. Put the mounting plate up to the wall so that the embossed letter “L” is on top (see figure). If the plate is correctly oriented, the circular tab that is vertically aligned with the square hole should be on top. 3. Fasten the mounting plate with two screws through the circular holes of the plate. Depending on the type of wall, you may need to use the two fasteners provided. 4. Holding the unit so that the connectors on the rear are facing left, align the two holes on the bottom of the unit with the two tabs on the mounting plate. Press the unit down so it is flush with the plate. 5. Carefully slide the unit to the right until the tabs snap securely onto the narrow holes of the unit. If the unit is mounted correctly, no portion of the mounting plate should protrude from any of the sides of the unit.

20

Page 21

Installation and Initialization Hardware Installation

AP-700 User Guide

Ceiling Mounting Follow these steps to mount the unit to a ceiling: 1. If the unit’s power supply is plugged in, unplug it. 2. Snap the rectangular tabs on the back of the mounting plate onto a ceiling T-bar. You may need to slightly rotate the plate until it securely snaps onto the T-bar. 3. Fasten the mounting plate to the ceiling tile with two screws through the circular holes of the plate. 4. Position so that the embossed letter “L” on the mounting plate is facing up (see previous figure). Holding the unit so that the connectors on the rear are facing to left, align the two holes on the bottom of the unit with the two tabs on the mounting plate. Press the unit up so it is flush with the plate. 5. Carefully slide the unit to the right until the tabs snap securely onto the narrow holes of the unit. If the unit is mounted correctly, no portion of the mounting plate should protrude from any of the sides of the unit.

Power On the Unit The AP can be powered by a power supply (just plug the power cord of the power supply into an AC power outlet), or by Power-over-Ethernet (connect a PoE DC injector to the Ethernet cable). When the unit is powered on, it performs startup diagnostics. When startup is completed, the LEDs show the operational state of the unit. The LED indicators exhibit the following behavior: Indication Solid Green Blinking Green Solid Amber

Ethernet Ethernet interface is connected at 100 Mbps with no traffic. Ethernet interface is connected at 100 Mbps with traffic. Ethernet interface is connected at 10 Mbps with no traffic.

Wireless Interface Power (802.11a/b/g radio) Wireless interface is preparing AP image running. for use. Wireless interface is transmitting n/a or receiving wireless packets. n/a The Bootloader is loading the application software.

21

Page 22

Installation and Initialization Hardware Installation Indication Blinking Amber

AP-700 User Guide

Ethernet

Wireless Interface (802.11a/b/g radio)

Power n/a

The AP is reloading.

Solid Red

The Ethernet interface is connected at 10 Mbps with traffic. n/a n/a

Blinking Red n/a n/a

Power On Self Test (POST) running. Rebooting.

Install External Antennas (Professional Installation Required) Optionally, you can connect two external antennas to your AP. All products using external antennas must be professionally installed, and the transmit power of the system must be adjusted by the professional installers to ensure that the system EIRP is in compliance with the limit specified by the regulatory authority of the country of application. See the following sections for more information: •

Connecting Antenna(s)

•

Adjusting Tx Output Power

•

Antenna Types and Maximum Gain

Connecting Antenna(s) Follow the mounting instructions included with your external antenna, and then connect the antenna cable to the AP, as follows: 1. Press down near the center of the compartment covering and slide open the external antenna access compartments. The compartment closer to the LED panel contains the connectors. NOTE: AP-700 models 8675-US2 and 8675-AU do not provide external antenna connectors for 5 GHz (802.11a) operation.

Figure 2-4 Opening the Antenna Compartment

22

Page 23

Installation and Initialization Hardware Installation

AP-700 User Guide

2. There are two antenna connectors in the AP-700, labeled 1 and 2. Connect the antenna cable to connector 1 (the connector closer to the LED panel in the compartment).

Figure 2-5 AP-700 Antenna Connectors 3. If installing a second external antenna (not recommended), connect the antenna cable to connector 2. 4. Close the external antenna access compartment. 5. If desired, manually select which antenna(s) to use through the Command Line Interface. See Configure Antenna Diversity. Adjusting Tx Output Power Use the following formula in combination with the table of EIRP limits in US and EU countries to calculate system transmit power (based on EIRP limits) of these countries: Tx Power (dBm) = EIRP Limit (dBm) + FL (dB) – G (dB) where: Tx Power = Output power measured at the antenna input EIRP Limit = EIRP limits specified below FL = Feeder loss including loss of connectors G = Antenna Gain Band

EIRP Limit (dBm) USA

2.4 - 2.4835 GHz (Point-to-Multipoint 2.4 - 2.4835 GHz (Point-to-Point)

36 When G < 6: 36 When G ≥ 6, use the following equation:

EU 20 20

–6 36 - G ------------3

5.15 - 5.25 GHz 5.25 - 5.35 GHz 5.47 - 5.725 GHz 5.725 - 5.850 GHz (Point-to-Multipoint) 5.725 - 5.850 GHz (Point-to-Point)

23 30 NA* 36 No limit

23 23 30 14 14

* Not certified for FCC regulatory domain.

23

Page 24

Installation and Initialization Hardware Installation

AP-700 User Guide

Antenna Types and Maximum Gain For devices using external antennas, professional installers should select only the antenna types listed in the following table, with gain not exceeding the listed maximum gain for each type. Frequency Band 2.4 GHz

5 GHz

Antenna Type Omni Panel Yagi Parabolic Omni Panel Sector Parabolic

Maximum Gain 10 14 14 24 13 28.2 17 33.4

24

Page 25

Installation and Initialization Initialization

AP-700 User Guide

Initialization The following sections detail how to initialize the AP using ScanTool, log in to the HTTP interface, perform an initial configuration of the AP using the Setup Wizard, and download the required AP software. •

Using ScanTool

•

Logging In

•

Using the Setup Wizard

•

Installing the Software

Using ScanTool ScanTool is a software utility that is included on the installation CD-ROM. It is an initial configuration tool that allows you to find the IP address of an Access Point by referencing the MAC address in a Scan List, or to assign an IP address if one has not been assigned. The tool automatically detects the Access Points installed on your network, regardless of IP address, and lets you configure each unit’s IP settings. In addition, you can use set initial device parameters that will allow the AP to retrieve a new software to an AP that does not have a valid software image installed (see Client Connection Problems). To access the HTTP interface and configure the AP, the AP must be assigned an IP address that is valid on its Ethernet network. By default, the AP is configured to obtain an IP address automatically from a network Dynamic Host Configuration Protocol (DHCP) server during boot-up. If your network contains a DHCP server, you can run ScanTool to find out what IP address the AP has been assigned. If your network does not contain a DHCP server, the Access Point’s IP address defaults to 169.254.128.132. In this case, you can use ScanTool to assign the AP a static IP address that is valid on your network. ScanTool Instructions Follow these steps to install ScanTool and initialize the AP: 1. Power up, reboot, or reset the AP. 2. Double-click the ScanTool icon on the Windows desktop to launch the program (if the program is not already running). If the icon is not on your desktop, click Start > All Programs > ORiNOCO > AP-700 > ScanTool. NOTE: If your computer has more than one network adapter installed, you will be prompted to select the adapter that you want ScanTool to use before the Scan List appears. You can use either an Ethernet or wireless adaptor. If prompted, select an adapter and click OK. You can change your adapter setting at any time by clicking the Select Adapter button on the Scan List screen. ScanTool scans the subnet and displays all detected Access Points. The ScanTool’s Scan List screen appears, as shown in the following example.

Figure 2-6 Scan List 3. Locate the MAC address of the AP you want to initialize within the Scan List.

25