There are 15 independent Channels designated 1 through 15. This means that there are 15 different sequences of frequency hops. Each Channel is at a different frequency at a different time. To minimize interference, set each Ethernet Adapter acting as a Master within the same area to a different Domain and Channel. In networks with multiple Access Points, set each Access Point to a different Channel but the same Domain to facilitate roaming. The Ethernet Adapter’s Channel may be set to a value between 0 and 15, and 0 is the default setting. When set to Channel 0, an Ethernet Adapter automatically selects a Channel upon boot-up based on the configured Domain number. The Channel selected is the Domain number plus 1. Therefore, if the Domain is set to 0, the Channel is 1. Note that the automatic selection procedure will choose Channel 15 when set to either Domain 14 or 15. This parameter is visible only when the Ethernet Adapter is set as a Master. All Stations will determine their channel by the Master to which they are synchronized. The Subchannel is a software code that is appended to each radio packet. It does not affect the frequency hopping sequence like a Channel does. Use a Subchannel if you need more than 15 Masters in the same area and, therefore, all the Channels are used. The Subchannels are designated 1 through 15, and 1 is the default setting. This parameter is visible only when the Ethernet Adapter is set as a Master. For example, you can use Channel 1, Subchannel 1 for Network A and Channel 1, Subchannel 2 for Network B. The two networks will not communicate with one another. They are, however, still sharing the 1.6 Mbps data rate since they are both using Channel 1.

35

Page 42

The optional Master Name parameter of up to 11 characters specifies an alphanumeric name to simplify the identification of each Master in your network. You may not have spaces in the name. This parameter is visible only when the Ethernet Adapter is set as a Master. To further improve the security of a wireless subnetwork, each unit requires the same Security ID to establish communication. The Security ID is used on all RangeLAN2 products and all Station Types. This ID is encrypted and stored within the RangeLAN2 Ethernet Adapter itself, not in software. It cannot be accessed, but you may change it. However, if you do change it, then you will need to change the Security ID on all of the other radios to the same new value to reestablish communication. The Security ID parameter can be up to 20 characters and is an empty string by default. There are 1,048,576 unique choices for the Security ID.

Note: The Security ID value is not a software parameter but is stored within the Ethernet Adapter’s radio. Therefore, if you choose the Reset Parameters to Factory Defaults option from within the Ethernet Adapter Main Menu, the Security ID will not be reset to its default value. The Repeating Enabled parameter gives the ability to enable or disable the RangeLAN2 repeating feature. When enabled, a RangeLAN2 Ethernet Adapter, acting as a Master, will repeat signals coming from one Station and destined for another Station. These two Stations must be out of range of one another, but both in range of the RangeLAN2 Ethernet Adapter for repeating to occur. 36

Page 43

However, be aware that by enabling the repeating feature, the network throughput will drop by as much as one-half when repeating occurs. This parameter is only visible when the Ethernet Adapter is configured as a Master. By default, Repeating is disabled. See Chapter 3 for more information on Repeating. The MAC Optimize parameter can help improve throughput for small networks. The default setting of Auto allows the RangeLAN2 Ethernet Adapter to determine the number of units synchronized to it and to then adjust this parameter accordingly. Alternately, you may force the parameter to one of the other settings. If you have 0 or 1 wireless nodes communicating with an Ethernet Adapter, use the Very Light setting. If you have between 2 and 7 wireless nodes communicating with an Ethernet Adapter at the same time, use Light. (You can have more than 7 nodes synchronized to an Ethernet Adapter but between 2 and 7 communicating at the same time for the Light parameter setting.) In networks with more than 7 concurrent wireless users, use Normal. The MAC Optimize parameter is visible only when the Ethernet Adapter is set as a Master. To conserve power, the RangeLAN2 Ethernet Adapter has an Inactivity Timeout doze mode for the radio. The doze mode is automatically engaged when a certain period of time has elapsed since the unit has sent or received data over its radio. An Ethernet Adapter in doze mode will wake up when a Master unit attempts to send data to it. There is no inactivity timeout set by default, but you may change this to any interval of 10 seconds. This parameter is visible only when the Ethernet Adapter is set as a Station.

37

Page 44

The Roam Config parameter allows you to determine how quickly an Ethernet Adapter, set as a Station, will roam from one Master Access Point to another. In areas with many RangeLAN2 Access Points that provide heavy overlapping coverage, set this parameter to Fast to maintain high throughput for each of the wireless nodes. In most networks, set the Roam Config parameter to Normal. Wireless node throughput will not change noticeably, and an overabundance of RangeLAN2 Access Points is not required. If the wireless coverage area provided by RangeLAN2 Access Points is sparse, set the Roam Config parameter to Slow. Wireless nodes will not roam until they are nearly out of range of the RangeLAN2 Access Point to which they are synchronized. This parameter is visible only when the Ethernet Adapter is set as a Station.

Note: Note that wireless clients can NOT roam between multiple Ethernet Adapters set as Masters or between a RangeLAN2 Access Point and an Ethernet Adapter. RangeLAN2 products only support roaming between Access Points and Extension Points. You may choose to disable a RangeLAN2 Ethernet Adapter’s ability to roam from one Master RangeLAN2 Access Point to another with the Roaming Enabled parameter. This feature is enabled by default and is visible only when the Ethernet Adapter is set as a Station.

38

Page 45

7. Advanced Configuration Menu Use these parameters to configure the advanced features of the RangeLAN2 Ethernet Adapter.

Eth ern et Ad ap ter M ain M en u

D isp lay Param eter Valu es R eset Param eters to Facto ry D efau lts R ad io C o n figu ratio n M en u Ad van ced C o n fig u ratio n M en u

S et IP Ad d ress

F orw ard in g D atab ase T ab le T im eo u t

C PU Po w er S ave M o d e

Ech o M od e

T echn ical Su p p ort Access View Statistics D o w n lo ad N ew So ftw are Versio n R eset th e Eth ern et Ad apter Exit

39

Page 46

Advanced Parameters Parame te r Name

Rang e

De fault

Se t IP Ad d re ss

-

0.0.0.0

Fo rward ing Datab ase Tab le Time o ut

10 to 1,000,000 se co nd s

300

CPU Po we r Save Mo d e

Y/ N

No

Echo Mo d e

No ne , Simp le , and Te rminal

Te rminal

Te chnical Sup p o rt Ac c e s s

N/A

N/A

Set IP Address allows you to assign the Ethernet Adapter a unique network IP address. If the unit is attached to an Ethernetready device, do not assign the Ethernet Adapter the same IP address as the Ethernet-ready device. The Ethernet Adapter must have its own IP address if you choose to give it one.

Note: The IP Address parameter is provided for diagnostic purposes so that a remote system may ping the Ethernet Adapter. The Forwarding Database Table Timeout parameter allows you to control the length of time the Ethernet Adapter will hold a learned address of a network node in its Forwarding Database Table. This data is dynamically acquired by the RangeLAN2 Ethernet Adapter so that it can forward packets properly to wired and wireless nodes. By default, a Forwarding Database Table entry will expire after 300 seconds or 5 minutes.

40

Page 47

The CPU Power Save Mode parameter will reduce the amount of power drawn by the Ethernet Adapter during operation. This is a useful feature for customer who are powering the Ethernet Adapter with a battery.

Note: Enabling the CPU Power Save Mode will reduce the Ethernet Adapter’s rate of data transfer. The Ethernet Adapter’s serial port supports three Echo Modes when configuring the unit through a terminal session: None, Simple, and Terminal. When set to None, the Ethernet Adapter will not echo typed characters to the terminal screen. When set to either Simple or Terminal, all characters typed are echoed to the screen during a terminal session. The Ethernet Adapter is set to Terminal mode by default. This parameter will only affect the appearance of data within the configuration menu; it plays no role in normal operation. The Ethernet Adapter configuration menu contains several parameters that are not needed for normal operation. A password is needed to enable Technical Support Access to view these settings. If you call Proxim Technical Support, they may ask you to enable the Technical Support parameters, but, in general, you will not need to access these parameters.

41

Page 48

42

Page 49

8. Display Parameter Values The Ethernet Adapter displays all of the relevant parameters in one centralized location. By choosing “Display Parameter Values,” you can view the current and configured values for the Radio and Advanced parameters. Current values are already in use by the Ethernet Adapter. If the configured value is different from the current value, the Ethernet Adapter must be reset before the configured value takes effect and at that time, the configured value becomes the new current value. The diagram on the next page shows the software trees associated with the Display Parameter Values menu.

43

Page 50

E the rne t Ada pte r M a in M e nu

D ispla y P a ra m e te r V a lue s

R a dio Pa ra m e te rs

D o m a in

C ha nn e l

S u bc ha n ne l

S ta tion T y pe

M a ste r N a m e

R e pe a ting E na ble d

M AC O ptim ize

In a c tivity T im e out (se c .)

R o a m C onfig.

R oa m ing E na ble d

Adva nc e d C onfigu ra tio n Pa ra m e te rs

IP Addre ss

Filte r T a b le T im e out (se c .)

C P U Pow e r S a ve M ode E na b le d

E c ho M ode

T e c h S upport Ac c e ss E na b le d R e se t Pa ra m e te rs to Fa c tory D e fa ults R a dio C onfigura tion M e nu Adva n c e d C onfigu ra tion M e n u V ie w S ta tistic s D ow nloa d N e w S o ftw a re V e rsion R e se t the E the rne t Ada pte r E x it

Dotted Line - Visible w hen configured as a M aster Dashed Line - Visible w hen configured as a Station

44