Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 4

Harmony OpenAir Access Point Model 7550 User's Guide, pages 21 to 30

Pages 21 to 30 of 37

The original document is the PDF (355 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Proxim 7550

Page 21

By default, the Harmony System will automatically provide a Channel assignment to a Harmony OpenAir Access Point. The Harmony System will assign Channel 1 through 15 to the first 15 Access Points. The Harmony System will assign Channel 1 to the 16th Access Point, Channel 2 to the 17th Access Point, and so on. If necessary, you may manually configure the Channel assignment of an OpenAir Access Point using the Harmony System’s Web browser interface. If you have more than 15 Access Points on the network, make sure that units that share the same Channel are as far away from each other as possible, based on the results of your site survey of the facility. This will minimize interference between the two radios.

Note: Proxim recommends that you manually assign Channels if you have more than 15 Harmony OpenAir Access Points on one network. Subchannel The Subchannel is a software code that is appended to each radio packet. It does not affect the frequency hopping sequence like a Channel does. Use a Subchannel if you need more than 15 Access Points in the same coverage area and, therefore, all the Channels are used. For example, you can use Channel 1, Subchannel 1 for Access Point A and Channel 1, Subchannel 2 for Access Point B. The mobile clients in cell A will not communicate with the Access Point or clients in cell B and vice versa. However, both cells are still sharing the same 1.6 Mbps pipe since they are both using Channel 1. By default, the Harmony System will assign Subchannel 1 to the first 15 Access Points, Subchannel 2 to the next 15 Access Points, and so on. There are 15 Subchannels, designated 1 through 15. If necessary, you may manually configure the Subchannel for each Access Point using the Harmony System’s Web browser interface.

21

Page 22

In general, Access Points that share the same Channel should have different Subchannels and be installed as far away from each other as possible, based on the results of your site survey of the facility. Master Name The optional Master Name parameter specifies an alphanumeric name to simplify the identification of each Access Point when using a mobile client’s radio diagnostic tools. The Master Name may be up to 11 characters long. The default Master Name is “MASTER.” Security ID To further improve the security of a radio subnetwork, each OpenAir device requires the same Security ID to establish communication. The Security ID is used on all OpenAir products. This ID is encrypted and stored in the Harmony OpenAir Access Point itself, not in software. It cannot be accessed but you can change it. If you do change it, however, you will need to change the Security ID on all other radios with which this one was communicating. The Security ID parameter can be up to 20 characters and is an empty string by default. It is case sensitive. MAC Optimize The MAC Optimize parameter can help improve throughput for small networks. If you have zero or one mobile client communicating with an Access Point, set this parameter to Very Light. If you have between two and eight mobile clients communicating with an Access Point at the same time, set this parameter to Light. (You can have more than eight nodes synchronized to an Access Point but between two and eight communicating at the same time for the Light parameter setting.) In networks with more than eight concurrent mobile users, set the parameter to Normal.

22

Page 23

When configured to Auto, the default setting, the Access Point automatically determines the number of units synchronized to it and adjusts this parameter accordingly. Proxim recommends that you configure each of your OpenAir Access Points to Auto so that each Access Point can change this setting as necessary. IP Addressing An Access Point must have a unique IP address in the same IP subnet as the System’s AP Controllers in order to partner with one of the AP Controllers (unless the Access Point is installed on a remote subnet, in which case, refer to the “Subnet Table” section in Chapter 5 of the Harmony Access Point Controller Model 7560 User’s Guide for details).

Note: If you have assigned static IP addresses to the System’s AP Controllers and you do not have a DHCP server on the network, then the Access Point will not partner with one of the AP Controllers until you have specified an IP address for the Access Point within the Web browser interface. You can configure an Access Point’s IP address in one of three ways: q The Access Point may receive a dynamic IP address from a network DHCP (Dynamic Host Configuration Protocol) server. q The Access Point is assigned a default IP address of 169.254.x.y at the factory. This IP address is printed on the underside of the unit along with its serial number and physical (or MAC) address. The Access Point will use this IP address if it is configured to Use DHCP and a DHCP server is not present on the network. q You can assign the Access Point a specific IP address via the Harmony System’s Web browser interface. The AP Controller assigns the Access Point the specified IP address using DHCP.

23

Page 24

If you want the Access Point to receive an IP address via the first or second method described above, then choose the Use DHCP option within the Access Point’s configuration screen (accessed via the Web browser interface). Note that Use DHCP is the Access Point’s default setting. Otherwise, select Specify IP and enter a static IP address, subnet mask, and default gateway in the fields provided. Click <SAVE> within the Access Point’s configuration screen to save these changes. Any changes to the Access Point’s IP Addressing parameters will take effect immediately (if the System’s AP Controllers are running firmware version 1.1 or greater). However, if you find that the new IP address has not taken effect, try recycling power on the Access Point.

Note: Refer to the Harmony Access Point Controller Model 7560 User’s Guide for information on additional Access Point parameters, such as Group Membership and Auto Image Synchronization Upon Reboot.

24

Page 25

5. Performance Hints This section suggests several ways to improve the performance of a Harmony OpenAir network.

Microwave Ovens Microwave ovens operate in the same frequency band as the Harmony OpenAir Access Point. Therefore, if you use a microwave within range of the Access Point you may notice network performance degradation. However, both your microwave and your Access Point will continue to function.

Antenna Options The OpenAir Access Point is shipped with a standard directly connected antenna. To install the antenna, screw it clockwise onto the antenna connector. Proxim sells several antenna alternatives, including higher gain omnidirectional and directional antennas that can increase the range of the products. Each of these antennas ship with installation and mounting instructions. For information on additional antenna options, please contact your Proxim Sales Representative.

Range Every environment is unique with different obstacles, barriers, materials, etc. and, therefore, it is difficult to determine the exact range that will be achieved without testing. However, Proxim has developed some guidelines to estimate the range that users will see when the product is installed in their facility, but there are no hard and fast specifications. Radio signals may reflect off of some obstacles or be absorbed by others depending on their construction. For example, with two OpenAir radios, you may achieve up to 1000' in open space outdoors where the two antennas have line of sight, meaning they see each other with no obstacles. However, the same two units may only achieve up to 300' of range when used indoors.

25

Page 26

Proper antenna placement can help improve range. Here are some guidelines: q The antenna should be placed so that it emits its signal in the appropriate direction. For example, the standard antenna shipped with the unit should be mounted vertically. Higher gain omnidirectional antennas may be mounted upside down to the ceiling or a beam. The omnidirectional antenna emits its signal from all sides of the antenna but not from the top or bottom. The directional antenna typically emits a beam only from a front face plate in a horizontal direction. This type of antenna should be mounted against a wall. q Place the antenna as high as possible. In an office environment, try to place it above cubicle walls. q Do not place a sheet of metal (like a filing cabinet) between two antennas. q Two antennas that are communicating should be in the same plane. For example, do not place one antenna on its side and have its partner standing upright.

Using Harmony With Other OpenAir-Compatible Products Harmony OpenAir products are designed to be compatible with existing devices that use the OpenAir standard, such as Proxim’s RangeLAN2 product line. For example, a RangeLAN2 PC Card can communicate with a Harmony OpenAir Access Point, and a Harmony OpenAir PC Card can communicate with a RangeLAN2 Access Point. Refer to the Harmony Access Point Controller Model 7560 User’s Guide for information on how to deploy Harmony on a network that already uses RangeLAN2.

26

Page 27

6. Troubleshooting The Harmony OpenAir Access Point is designed to be very easy to install and operate. However, if you experience difficulties, use the information in this chapter to help diagnose and solve problems. Also, refer to the Harmony Access Point Controller Model 7560 User’s Guide for additional troubleshooting suggestions. If you cannot resolve a problem, contact Proxim Technical Support, as described in Appendix C, “How to Reach Technical Support.”

How to Obtain Help with Your LAN Installation If you require assistance to install your LAN, Proxim can put you in contact with a Harmony reseller in your area. The reseller is an expert in the design, installation, and maintenance of LANs and will be able to examine your needs and recommend the most cost-effective solution for your LAN, whether you are installing a new LAN or adding on to an existing one. For the location of the Harmony reseller nearest you, contact Proxim at 1-800-229-1630 and ask for the Sales Department.

LED Error Codes The Status LED, located on the top of the Harmony OpenAir Access Point, will flash red in a repeating pattern to indicate the following errors: 1 blink: Memory error 2 blinks: Flash write error 3 blinks: Ethernet initialization error 4 blinks: Radio initialization error If you see any of the above flashing sequences, recycle power to the Access Point. If the flashing sequence persists after you have reset the unit, make a note of which of the above patterns you have and contact Proxim Technical Support.

27

Page 28

Common Problems and Solutions Problem 1: The AP Controller does not automatically detect a new Access Point. Solution 1: Follow these steps if an Access Point is not automatically recognized and configured by an AP Controller: 1.

Confirm that the Access Point’s Link LED is on. This means that the Access Point has a network connection. If the LED is not on, try another Ethernet cable. Also, confirm that you have connected the 10Base-T crossover adapter, included with the unit, to the Access Point’s 10Base-T port. If you do not have the 10Base-T crossover adapter, then use a 10Base-T crossover cable to connect the Access Point to the network.

Note: If you have connected the Harmony OpenAir Access Point to an AP Power Over LAN Module, do not use the 10Base-T crossover adapter. 2.

Try recycling power to the unit. The Access Point will try to contact an AP Controller during boot-up. Therefore, if you are using the external AC power supply, you should connect the Access Point to the Ethernet network before turning on the unit.

3.

Confirm that the Harmony System’s “Allow new APs to be added automatically” parameter is set to True. Refer to the Harmony Access Point Controller Model 7560 User’s Guide for details.

4.

If none of the above solves the problem, try to manually add the Access Point as described in the Harmony Access Point Controller Model 7560 User’s Guide.

Problem 2: I can’t configure the Access Point locally via the serial port.

28

Page 29

Solution 2: The serial port is nonfunctional. Configure the Access Point using the Harmony System’s Web browser interface. Problem 3: My Harmony OpenAir PC Card will not synchronize to the Harmony OpenAir Access Point. Solution 3: Follow these steps if an OpenAir client adapter cannot synchronize with the Access Point: 1.

Try to bring the devices closer together; the client adapter may be out of range of the Access Point.

2.

Confirm that the Access Point and client adapter have the same Domain number.

3.

Confirm that the Access Point and client adapter have the same Security ID.

4.

Confirm that the Access Point’s Status LED is green or use the Harmony System’s Web browser interface to confirm that it is partnered with an AP Controller. A client adapter cannot synchronize with an Access Point unless the Access Point is partnered with an AP Controller.

Problem 4: The Status LED is amber. Solution 4: The Status LED will turn solid amber under two conditions: q The unit is initializing q The unit has successfully initialized but could not find an AP Controller to partner with

29

Page 30

Open the Harmony System’s Web browser interface to determine if the Access Point has successfully partnered with an AP Controller. If the Access Point is not partnered with an AP Controller, refer to the steps in Solution #1 above. Also, confirm that the AP is enabled. A disabled Access Point cannot partner with an AP Controller. Problem 5: The Status LED is blinking amber. Solution 5: The Status LED will blink amber if the Access Point requires a new firmware image. The Access Point receives new firmware images from the AP Controller. Refer to the Harmony Access Point Controller Model 7560 User’s Guide for information on upgrading Access Point firmware. Problem 6: The throughput seems slow. Solution 6: 1. To achieve maximum throughput, verify that your antennas are well-placed, not behind metal, and do not have too many obstacles between them. If you move the client closer to the antenna and throughput increases, you may want to consider adding a second Access Point and implementing roaming. 2.

Check the AP Controller’s filter settings to confirm that it is not forwarding unnecessary Ethernet traffic to mobile clients.

Problem 7: How do I upgrade the firmware on an Access Point? Solution 7: The Access Point receives new firmware images from the AP Controller. Refer to the Harmony Access Point Controller Model 7560 User’s Guide for details.

30