The text of a manual · part 3 of 9
RangeLAN2 Extension Point Models 7540 and 7541 User's Guide, pages 21 to 30
Pages 21 to 30 of 84
The original document is the PDF (965 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Proxim 7541
Page 21
The figure below illustrates a two-hop topology. Each Extension Point is further from the wired 7510/752x/753x Access Point, allowing the final wireless clients to communicate at greater distances. Note that each Master, while on the same Domain, uses a unique Channel to create an independent 1.6 Mbps pipe, as described in Chapter 6.
Network Backbone
Master, Domain 0, Channel 3, Subchannel 3
Master, Domain 0, Channel 2, Subchannel 2
Station, Domain 0
RangeLAN2 754x Extension Point
Station, Domain 0
RangeLAN2 754x Extension Point
RangeLAN2 7510/752x/753x Access Point Master, Domain 0, Channel 1, Subchannel 1
Laptops w/RangeLAN2 7400 PC Cards
Figure 6 Multiple Linear Topology
Tree A tree topology is created when there are two or more Extension Points communicating directly with the same 7510/752x/753x Access Point. Each of the Extension Points can support wireless clients. The maximum recommended tree width is 3 Extension Points. The next figure shows two Extension Points, each supporting three wireless clients. Again, note that each Master, while on the same Domain, uses a unique Channel to create an independent 1.6 Mbps pipe.
14
Page 22
Network Backbone
Laptops w/RangeLAN2 7400 PC Cards Master, Domain 0, Channel 2, Subchannel 2
Station, Domain 0
RangeLAN2 754x Extension Point
RangeLAN2 7510/752x/753x Access Point
Master, Domain 0, Channel 3, Subchannel 3
Master, Domain 0, Channel 1, Subchannel 1
Station, Domain 0
RangeLAN2 754x Extension Point
Laptops w/RangeLAN2 7400 PC Cards
Figure 7 Tree Topology
Building-to-Building The Extension Point can be used to extend the range of a Building-to-Building link created using two 7510/752x Access Points. One of the 7510/752x Access Points is configured as a Master; the other as a Station. The BSA radio of the Extension Point communicates with the Station 7510/752x Access Point; the Backbone radio communicates with the Master 7510/ 752x Access Point. All radios are configured on the same Domain, and each Master radio has a unique Channel. The next figure illustrates this configuration. 15
Page 23
Network Backbone
Network Backbone
Master, Domain 0, Channel 2, Subchannel 2
RangeLAN2 7510/752x Access Point
Station, Domain 0
RangeLAN2 754x Extension Point
RangeLAN2 7510/752x Access Point Master, Domain 0, Channel 1, Subchannel 1
Station, Domain 0
Figure 8 Building-to-Building Topology
Roaming For seamless roaming, all RangeLAN2 devices in the network (7510/752x/753x Access Points, Extension Points, and PC Cards) must be configured with the same Domain and Security ID. For best performance, all radios configured as Masters in the network (7510/ 752x/753x Access Points and BSA radios in each Extension Point) should use different Channels when possible. If Channels must be reused, try to avoid using the same Channel in two adjacent cells. The user can move freely between the Extension Points and 7510/752x/753x Access Points in the network. When the roaming PC leaves the transmission range of one Access Point or Extension Point, the software automatically polls the other Access Points or Extension Points in the same Domain to continue the network connection. 16
Page 24
Note: If the roaming PC must remain connected to the network, cells must overlap for continuous coverage without gaps. Roaming stations will only roam among Access Points and Extension Points with the same Domain and Security ID.
Roaming Scenarios The following roaming scenarios are supported by the Extension Point: ❑ Roaming among Extension Points ❑ Roaming among Extension Points and 7510/752x/753x Access Points ❑ Backbone radios of Extension Points themselves roaming among Extension Points and 7510/752x/753x Access Points
How to Configure 7510/752x/753x Access Points When Using Extension Points The Repeating Enabled setting on the 7510/752x/753x Access Point defaults to False. If a tree topology is desired, all 7510/752x/753x Access Points must change that setting to True. If the default False setting is used, Extension Points will only be able to communicate in a linear (one hop, multiple linear, building to building) topology. You must have V1.3 or greater software on the 7510/752x/753x Access Point. Note that the Access Point software version number is visible in the upper right corner of the menu.
17
Page 25
18
Page 26
5. Configuration You need to configure the Extension Point if: ❑ There is more than one Extension Point on this network ❑ The 7510/752x/753x Access Point or Extension Point to which this Extension Point will synchronize is not configured at default Domain or Channel ❑ You need to change the software default values, including IP addresses ❑ You want to set Security IDs on your network There are four ways to configure the Extension Point: ❑ Locally via a null modem cable and a terminal or terminal emulation package ❑ Remotely across the network using a telnet session ❑ Remotely across the network using an SNMP management package ❑ Remotely across dial-up modems
Locally (Out-of-band) You may use the DB-9 Local Management Port on the back of the Extension Point to configure the unit. To locally configure the Extension Point, you need a null modem RS-232 cable with a nine pin female connector on the Extension Point side and a terminal or PC with an available serial port running a terminal application package.
Note: If you use a terminal application that has the option to check for the CD signal before establishing a connection, configure the software to ignore CD. Alternatively, verify that your null modem cable is a full handshake cable and pulls CD high.
19
Page 27
1. Connect the null modem RS-232 cable between the Extension Point Local Management Port and a free serial port on your terminal or PC. 2. Configure the terminal or terminal emulation package for 9600 bps N81 operation. If you are using a terminal emulation package, choose TTY as the terminal type. 3. Apply power to the Extension Point. During the boot process messages will be displayed on the terminal screen. When they are completed and you see the “Initialization Complete” message, press <Enter> to enter the software configuration menu. If the unit was already turned on, you can press <Enter> to display the menu.
Remotely (In-band) The second configuration option is remote configuration across the wired network.
Note: The Extension Point is not manufactured with a default IP address. In order to telnet to the Extension Point, you must first assign it a valid IP address for your network using null modem cable configuration or a BOOTP server. 1. From a wired or wireless client on your network, open a telnet session to the Extension Point. A wireless client must have some link to the Extension Point in order to open a telnet session. Either it is directly synchronized to the BSA radio on the Extension Point, or it is synchronized to a device that contains a wireless communications link through several other Extension Points.
Note: You cannot open more than one simultaneous telnet session, nor can you telnet to an Extension Point that is currently being configured locally. 2. You will be prompted for a password if you enabled this option through the TCP/IP Configuration Menu. 3. You will enter the configuration menu. 20
Page 28
Main Menu After using one of the above two methods, you will see the following software menu whose choices will be described in the next chapters:
M ain M enu
C onfiguration M enu
Statistics M enu
Status M enu
D ow nload M enu
D iagnostics M enu
R eset Extension Point
Note: Depending on the current settings of the Extension Point, the order of the options in the menu tree may change slightly.
SNMP Management You may configure and monitor the Extension Point using an SNMP management package. The Extension Point supports the following MIBs: ❑ MIB-II (RFC 1213) ❑ IEEE 802.1d Bridge MIB (RFC 1493) 21
Page 29
❑ Proxim Enterprise MIB The Proxim Enterprise MIB is supplied in ASN.1 format. It is available on the Proxim BBS and Web site. The filename is AP7540.MIB. Follow the instructions in your SNMP management package for incorporating enterprise-specific MIBs.
Modem Support The Extension Point may be remotely configured via a dial-up modem. To allow for this type of configuration: 1. Configure the modem from a terminal or terminal emulation program at 9600 bps. 2. Issue the following commands to the modem: ATS0=1 AT&D0 ATE0 ATQ1 AT&W0
(Auto-answer after 1 ring) (Ignore DTR) (No local echo) (Suppress result codes) (Store configuration in non-volatile memory)
3. Attach the modem via a straight-through cable to the Extension Point. 4. From a remote modem, dial the phone number of the modem connected to the Extension Point. 5. After the Extension Point's modem has answered the phone, press <Enter> on the terminal connected to the remote modem until you see the configuration menu tree .
22
Page 30
6. Configuration Parameters To configure the Extension Point, pick the Configuration option from the Main Menu. The following diagram illustrates the software tree:
C o nfig ura tio n M e nu
T C P /IP C o nfig ura tio n M e nu
IP A dd r es s
S u bn et M a sk
B O O T P S er v er ( 0.0 .0.0 fo r B r o ad ca st)
T e ln et A cce ss
D efa ult G atew a y A dd r es s
S en d B O O T P a t B o ot T im e
T e lne t P a ssw o r d
B rid g e C o nfig ura tio n M e nu
A g in g P e r io d ( se co nd s)
F o rw ard ing D B U s age T r ap Th r es hold ( %)
B S A R a d io C o nfig ura tio n M e nu
R a dio P o r t A d m inistr a tive S ta tus
C o nfigu r ed D om ain
C on fig ur e d C h an ne l
C on fig ur e d S ub ch an ne l
C o nfigu r ed E r r or D om ain
* C o nfigu r ed E r r o r D om ain T im er
* C on fig ur e d M a ster N a m e
R ep ea tin g E na ble d
D e lay R a dio R e co nfigu r e
M A C O ptim ize
N o T r affic T r a p P e r io d ( se co nd s)
R ad io T r a ffic T r a p T hr e sho ld ( % )
R a dio B r o ad ca st T r a p T hr e sh old ( % )
S e t S e cu r ity ID
R es et R ad io
* B a c k b o ne R a d io C o nfig ura tio n M e nu
R a dio P o r t A d m inistr a tive S ta tus
C o nfigu r ed D om ain
C on fig ur e d F ir s t M as te r T o S ync T o
H ig h P r ior ity P r oto col E na bled
D e lay R a dio R e co nfigu r e
R o am in g E n ab le d
S et S ecu r ity ID
R es et R ad io
S N M P C o nfig ura tio n M e nu
E n ab le /D is ab le S N M P
R e ad - O n ly S N M P C o m m u nity
R ea d- O n ly S N M P M an ag er IP A dd r ess
R ea d/W r ite S N M P C o m m un ity
R e ad /W r ite S N M P M a na ge r IP A d dr e ss
S N M P T r ap C om m un ity
T r a p T ar g et A dd r es s
E na ble/D isa ble A uth en tic ation T r a ps
+ R eset Extension Point to Factory D efaults
D um p C o nfig ura tio n to S c re e n
S ta tis tic s M e nu
S ta tus M e nu
D o w nlo a d M e nu
+ N ot A ccessible via Telnet * N ot configurable via S N M P
D ia g no s tic s M e nu
R e s e t E x te ns io n P o int
23