Page 25
• Total Number of Fields
• Applicable Code Type
1
All 4
Clear
2
Code 39 5
Italy Pharmacode
3
French Pharmacode Industrial 25
6 Interleave 25
Matrix 25 Codebar Code 93 Code 128 EAN128/RSS UPCE No Addon UPCE Addon2 UPCE Addon5 EAN8 No Addon EAN8 Addon2 EAN8 Addon5
Update
43
44
End of Format Programming
Page 26
•
• Field1 Setting Divide Field by Field Terminating String
EAN13 No Addon
Field Terminating String * EAN13 Addon2
Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
EAN13 Addon5
UPCA No Addon
Include Terminating String
UPCA Addon2
Discard Terminating String UPCA Addon5 Divide Field by Field Length MSI Field Length * Programming Instructions: (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 52) to complete this setting.
Plessey
Update
45
46
End of Format Programming
Page 27
• Field2 Setting
• Field3 Setting Divide Field by Field Terminating String
Divide Field by Field Terminating String
Field Terminating String *
Field Terminating String *
Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
Include Terminating String
Include Terminating String Discard Terminating String
Discard Terminating String
Divide Field by Field Length
Divide Field by Field Length
Field Length *
Field Length *
Programming Instructions: (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 52) to complete this setting.
Programming Instructions: (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page 52) to complete this setting.
Update
47
48
End of Format Programming
Page 28
• Field4 Setting
• Field5 Setting
Divide Field by Field Terminating String
Divide Field by Field Terminating String
Field Terminating String *
Field Terminating String *
Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
Include Terminating String
Include Terminating String Discard Terminating String
Discard Terminating String
Divide Field by Field Length
Divide Field by Field Length
Field Length *
Field Length *
Programming Instructions: (1) Read the label. (2) Program the desired length by on page 53. (3) Read the “Validate” label (also on page 53) to complete this setting.
Programming Instructions: (1) Read the label. (2) Program the desired length by reading Decimal Digits on page 52. (3) Read the “Validate” label (also on page52) to complete this setting.
Update
49
50
End of Format Programming
Page 29
• Additional Fields Setting
• Field Transmission Sequence
Additional Field 1 *
Start Additional Field 4 * Field 1
Additional Field 2 *
Additional Field 1
Additional Field 5 * Field 2
Additional Field 3 *
Additional Field 2
Programming Instructions: (1) Read the label. (2) Program the desired character string by reading Hexadecimal Digits on page 53. One character consists of 2 hexadecimal digits. (3) Read the “Validate” label (also on page 53) to complete this setting.
Field 3 Additional Field 3 Field 4 Additional Field 4 Field 5 Additional Field 5 Field 6
End Programming Instructions: (1) Read the “Start” label. (2) Program the desired transmission sequence by reading the Field / Additional Field labels. (3) Read the “End” label to complete this setting.
Update
51
52
End of Format Programming
Page 30
Decimal Digits
Hexadecimal Digits
LAAN LAANAIT
WAAR IAAL
LAMINA LAAMINUI AANA IMI WAARA AIK
AT LAAMIAIILI ° IAAI ° WAAR ALI
LAAN UM LAAN UII ‘ IAARUII WAAR ULI
LAAMTIM LAAMTIIUI ° ‘ WAAR ANU ‘ IAAIULAIII
LAMM °, WAIL
IAARAOUITI vA D WAAL
IAAI ° WAAMAUUILI
F e Validate IAAMLMUI I UNIO A 53 5A UN LLU ORLY VUE AUNT
Update
Enter Setup
Page 31
Key Type
KBD Wedge Character Table 0 1 2 3 4 5 6 7 8 b 0 F2 SP 0 @ P ` p c 1 Ins F3 ! 1 A Q a q d 2 Del F4 " 2 B R b r e 3 Home F5 # 3 C S c s f 4 End F6 $ 4 D T d t g 5 Up F7 % 5 E U e u h 6 Down F8 & 6 F V f v i 7 Left F9 ' 7 G W g w j 8 BS F10 ( 8 H X h x k 9 HT F11 ) 9 I Y i y A LF F12 * : J Z j z B Right ESC + ; K [ k { C PgUp Exec , < L \ l | D Enter = M ] m } E PgDn . > N ^ n ~ F F1 / ? O _ o Dly Enter* Enter* : Enter Key of the Numeric Key Pad b…k : Digits of Numeric Key Pad
< Normal > Scan Code
Key Status Add Shift Add Control (L) Add Alternate (L) Add Control (R) Add Alternate (R)
RS-232 Character Table 0 0 1 2 3 4 5 6 7 8 9 A B C D E F
Update
55
SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI
56
1 2 DLE SP DC1 ! DC2 " DC3 # DC4 $ NAK % SYN & ETB ' CAN ( EM ) SUB * ESC + FS , GS RS . US /
3 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
4 @ A B C D E F G H I J K L M N O
5 P Q R S T U V W X Y Z [ \ ] ^ _
6 ` a b c d e f g h i j k l m n o
7 p q r s t u v w x y z { | } ~ DEL