Page 37

Group 17: General Parameters

ENTER GROUP

EXIT

Upper Case Lower Case (*)

Universal ALT Mode

Buzzer Pitch (Default : 21) Buzzer Duration (Default: AA) Buzzer Pitch & Buzzer Duration Setting: Scan Enter Group 17 Label --> Scan Buzzer Pitch or Buzzer Duration Label --> Scan Two Digit Labels in Table-Hex --> Scan Confirm Label in Table-Hex --> Scan Exit Label

Power Up Beeping Disable Enable (*)

Normal Turbo (*)

36

Page 38

Group 18: Code ID Setting

ENTER GROUP

EXIT

CODE 39/CODE 32 INTERLEAVED 2 OF 5 INDUSTRIAL 2 OF 5 MATRIX 2 OF 5 CHINA POSTAGE CODE 128 CODE 93 CODE 11 MSI/PLESSEY CODABAR/NW7 EAN-13 EAN-8 UPC-E UPC-A CODE 4 Note: Refer to ASCII Table, scan two hexadecimal labels in Table Hex to represent one character

37

Page 39

Group 19: WAND Type Parameters

ENTER GROUP

EXIT

BAR=LOW BAR=HIGH(*) Scan Speed Lowest Low (*)

High Highest Data Format

Transmit in Normal Format (*)

Transmit in Code 39 Format Transmit in Code 128 Format

38

Page 40

Group 20-1: (Magnetic Parameters)

ENTER GROUP EXIT

Enable (*) Disable Track Order Track 1/2/3 (*) Track 1/3/2

Track 2/1/3 Track 2/3/1

Track 3/2/1 Track 3/1/2

Note: Options marked by ( ) are only available upon request

39

Page 41

Group 20-1: (Magnetic Parameters)

ENTER GROUP EXIT Track Selection Track 1&2&3 any (*) Track 1 only

Track 2 only Track 3 only

Track 1 and 2 Track 2 and 3

Track 1 and 2 and 3

ISO (*) (JIS-2)

Note: Options marked by ( ) are only available upon request

40

Page 42

Group 20-2: (Magnetic Parameters)

ENTER GROUP

EXIT Start Sentinel: (SS) Tk1 Default : % Tk2 Default: ;

Tk3 Default: ; End Sentinel: (ES) Tk1&2&3 Default: ? DLE: Tk1 Default : Null Tk2 Default: Null

Tk3 Default: Null STX: Tk1&2&3 Default: Null Magnetic Output Data Format: STX - Tk1 Start Sentinel - Tk1 Data - End Sentinel - Tk1 - DLE STX - Tk2 Start Sentinel - Tk2 Data - End Sentinel - Tk2 - DLE STX - Tk3 Start Sentinel - Tk3 Data - End Sentinel - Tk3 - DLE

Note: Options marked by ( ) are only available upon request

41

Page 43

Group 21: (Function Key Emulation)

ENTER GROUP

EXIT

Enable Enable Function Key Emulation: Scan Enter Group 21 Label --> Scan Enable Label --> Scan Exit Label

Disable (*)

1: To concatenate a function key with input data, please refer to Function Key Table for its hexadecimal representation. For Example: Preamble data with F1 Scan Enter Group 6 Label --> Scan Preamble Label --> Scan Label 0 and 1 respectively in Table-Hex (Page 45) --> Scan Confrim Label in Table-Hex (page 45) --> Scan Exit Label Function Key Table (Full ASCII Code 39 Table) F1:01 F2:02 F3:04 F4:04 F5:05 F6:06 F7:07 F8:08 F9:09 F10:0A F11:0B F12:0C Enter:0D Tab:0E BS:0F Up:10 Down:11 Left:12 Home:14 End:15 PgUp:16 PgDn:17 Ins:18 Del:19 Esc:1B Right:13 S-Tab:1C 2: To scan a function key barcode label, Full ASCII must be enabled. Please refer to Full ASCII Code 39 Table to produce the function key barcode label.

Full ASCII Code 39 Enable

42

Page 44

Function Code for PC XT/AT

F1 ($A) F7 ($G) F2 ($B) F8 ($H) F3 ($C) F9 ($I) F4 ($D) F10 ($J) F5 ($E) F11 ($K) F6 ($F) F12 ($L)

43

Page 45

Function Code for PC XT/AT

Enter ($M) End ($U) ($B) Tab ($N) PgUp ($V) BS ($O) PgDn ($W) Up ($P) Ins ($X) Down ($Q) Del ($Y) Left ($R) Esc (%A) Right ($S) Home ($T)

44