Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 6

Barcode Scanner Magstripe Decoder & Scanner Programming Manual, pages 1 to 9

Pages 1 to 9 of 52

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the POS-X Xi1000

Page 1

Barcode Scanner Magstripe

Decoder & Scanner

Programming Manual

Page 2

CONTENTS Getting Started ............................................................ 2 Setup Procedures ....................................................... 3 Setup Flow Chart .........................................................4 Group 0 : Interface Selection................................ 5 Group 1 : Device Selection for keyboard Interface.............................................6-7 Group 2 : Inter-character Delay.............................8 Group 3 : Language for Keyboard Interface... 9-10 Group 4 : Terminator......................................11-12 Group 5 : Scan Mode.....................................13-14 Group 6 : Preamble and Postamble.....................15 Group 7 : RS-232 Parameters........................ 16-18 Group 8 : Code 39 / Code 32..........................19-20 Group 9-1 : Interleaved 2 of 5................................ 21 Group 9-2 : Industrial 2 of 5 / IATA....................... 22 Group 9-3 : Matrix 2 of 5....................................... 23 Group 9-4 : China Postage..................................... 24 Group 10 : Code 128............................................. 25 Group 11 : Code 11............................................... 26 Group 12 : Code 93............................................... 27 Group 13 : MSI-PLESSY...................................... 28 Group 14 : Codabar/NW7..................................... 29 Group 15 : Code 4................................................. 30 Group 16-1 : EAN-13/JAN-13................................. 31 Group 16-2 : UPC-A ................................................32 Group 16-3 : EAN-8/JAN-8..................................... 33 Group 16-4 : UPC-E................................................. 34 Group 16-5 : ISBN/ISSN..........................................35 Group 17 : General Parameter............................... 36 Group 18 : Code ID Setting.................................. 37 Group 19 : Wand Type Parameters....................... 38 Group 20-1 : Magnetic Parameters..................... 39-40 Group 20-2 : Magnetic Parameters...........................41 Group 21 : Function Key Emulation.....................42 Function Code for PC XT/AT. ..................... 43-44 Table-Hex : Hexadecimal. .............................. 45 ASCII Table. .................................................. 46 Hexadecimal-Decimal Conversion Table. ......... 47 Pin Assignments .................. ..................... 48-49

1

Page 3

Getting Started Installing Keyboard Wedge Scanner To install a keyboard wedge barcode scanner, follow the steps listed below: 1) Make sure that the scanner has the correct Y (U)cable for the system (a PC or terminal) 2) Turn off the power of the system 3) Unplug the keyboard from the system 4) Connect the Y (U)- cable to the system and keyboard 5) Turn on the power of the system 6) If the indicator LED lights up and the buzzer sounds, the scanner is ready for reading

Installing a RS-232 Interface Barcode Scanner To install a RS-232 interface scanner, the host device should have a RS-232 port to receive data from the scanner, follow the steps listed below: 1) Make sure that the scanner has the right connector for the RS-232 port of the host device 2) Make sure that there is a power supply to the scanner (if necessary) 3) Connect the cable to the RS-232 port of the device 4) If the indicator LED lights up and the buzzer sounds, the scanner is ready for reading

2

Page 4

Barcode Scanner Setup Procedures

1) Locate a group that contains the parameters to be changed. 2) Scan the "Enter Group #" label. The scanner will sound beeps indicate that setup is in progress 3) Scan the label representing the parameter to be changed 4) Scan the "Exit" to end the group currently selected, the scanner will sound beeps 5) Repeat the procedure for other groups including the parameters to be changed

Example 1: Set the operating mode to "Continuous mode" 1) Scan "Enter Group 5" 2) Scan "Continuous/Trigger off" 3) Scan "Exit"

Example 2 Assign Preamble string as "#", and postamble string as "END" 1) Scan "Enter Group 6" 2) Scan Preamble 3) Scan "#" from "Full ASCII Table and Table-Hex." 4) Scan "Confirm" Label in Table-Hex 5) Scan "Postamble" 6) Scan "E", "N", "D" from "Full ASCII Table and Table Hex" consecutively 7) Scan "Confirm" Label in Table-Hex. 8) Scan Exit

3

Page 5

Setup Flow Chart

ENTER GROUP

SELECT ITEMS

EXIT

Set All Defaults

Show Version

Note: (*) denotes default setting options marked by ( ) are only available upon request.

4

Page 6

Group 0: Interface Selection

ENTER GROUP

EXIT

KEYBOARD

RS-232

(WAND)

(OCIA)

(DTMF)

Reserved 2

Resered 3

Reserved 4 Note: The interface is pre-set at factory according to the model of the device.

5

Page 7

Group 1: Device Selection for Keyboard Interface

ENTER GROUP

EXIT

PC/AT, PS/2 50,60,70,80(*) PC/XT PS/2 25, 30 (NEC 9801) (IBM 5550) (PS 55) (NEC N5520) (ACER 7300) (KW105D/ CT-700A/WANG 5120) (WANG 5425) (MAC_SE) (LC-6533) Note: Options marked by ( ) are only available upon request.

6

Page 8

Group 1: Device Selection for Keyboard Interface

ENTER GROUP

EXIT

(IBM3196, 3197, 3476, 3477)

Reserved Q

Reserved R

Reserved T

IBM3197

IBM 3476

IBM3477

Reserved 5

Reserved 6

Reserved 7

Reserved 8

Reserved 9

7

Page 9

Group 2: Intercharacter Delay

ENTER GROUP

EXIT

Start Keyboard Setting Scan Enter Group 2 Label -- > Scan Start Keyboard (or RS-232) Setting Label --> Scan two digits labels in Table-Hex --> Scan Exit Label

Start RS-232 Setting

Keyboard Default Value: 05 RS-232 Default Value : 00

8