Page 41

Start configuration

ITEM

Check-sum transmission

End configuration

OPTION

* Disable

Enable Min. code length (Default: 00)

Ref: Appendix (0-50H)

Max. code length (Default: 50H)

Ref: Appendix (0-50H)

Truncate Leading (Default: 00)

Ref: Appendix (00-7EH)

Truncate Ending (Default: 00)

Ref: Appendix (00-7EH)

Insert group selection Ref: Appendix (00-02H)

- 41 -

Page 42

3.8 Code 128

Start configuration

ITEM

Read

End configuration

OPTION

Disable

* Enable

Code ID setting (Default : M)

Check-sum verification

Ref: Appendix (20-7EH)

Disable

* Enable

- 42 -

Page 43

Start configuration

ITEM

Check-sum transmission

End configuration

OPTION

* Disable

Enable

FNC2 Append

* Disable

Enable

UCC/EAN128

* Disable

Enable

FNC1 transmission

* Disable

Enable

- 43 -

Page 44

Start configuration

ITEM

End configuration

OPTION

Truncate Leading (Default: 00)

Ref: Appendix (00-7FH)

Truncate Ending (Default: 00)

Ref: Appendix (00-7FH)

Min. code length (Default: 00)

Ref: Appendix (00-7FH)

Max. code length (Default: 7FH)

Ref: Appendix (00-7FH)

Insert group selection (Default: 00)

Ref: Appendix (00-02H)

- 44 -

Page 45

3.9 Interleaved 2 of 5

Start configuration

ITEM

Read

End configuration

OPTION

* Disable

Enable

Code ID setting (Default : N)

Check-sum verification

Ref: Appendix (20-7EH)

Disable

*Enable

Check-sum transmission

Disable

* Enable

- 45 -

Page 46

Start configuration

ITEM

End configuration

OPTION

Truncate Leading (Default : 00)

Ref: Appendix (00-7EH)

Truncate Ending (Default : 00)

Ref: Appendix (00-7EH)

Min. code length (Default : 00)

Ref: Appendix (00-7FH)

Max. code length (Default : 7FH)

Ref: Appendix (00-7FH)

Insert group selection (Default : 00)

Ref: Appendix (00-02H)

- 46 -

Page 47

3.10 Industrial 2 of 5

Start configuration

ITEM

Read

End configuration

OPTICON

* Disable

Enable

Code ID setting (Default : O)

Ref: Appendix (20-7EH)

Min. code length (Default : 00)

Ref: Appendix (00-32H)

Max. code length (Default : 32H)

Ref: Appendix (00-32H)

- 47 -

Page 48

Start configuration

ITEM

End configuration

OPTION

Truncate Leading (Default : 00)

Ref: Appendix (00-32H)

Truncate Ending (Default : 00)

Check-sum verification

Ref: Appendix (00-32H)

* Disable

Enable

Check-sum transmission

Disable

* Enable Insert group selection (Default : 00)

Ref: Appendix (00-02H)

- 48 -

Page 49

3.11 Matrix 2 of 5

Start configuration

ITEM

Read

End configuration

OPTION

* Disable

Enable

Code ID setting (Default : P)

Check-sum verification

Ref: Appendix (20-7EH)

* Disable

Enable

- 49 -

Page 50

Start configuration

ITEM

Check-sum transmission

End configuration

OPTION

Disable

* Enable

Truncate Leading (Default : 00)

Ref: Appendix (00-50H)

Truncate Ending (Default : 00)

Ref: Appendix (00-50H)

Min. code length (Default : 0B)

Ref: Appendix (00-50H)

Max. code length (Default : 50H)

Ref: Appendix (00-50H)

Insert group selection (Default : 00)

Ref: Appendix (00-02H)

- 50 -