Page 55

X p l o r e r

G L X

U s e r s ’

G u i d e

49

Special functions, output-control functions, and logic operators and functions are typically used to control the GLX’s digital and audio output. See “Outputcontrol Calculations” on page 50 for detailed explanations of these functions and operators.

Inserting a Function When you select an item from one of the Functions menus, it is inserted at the cursor location.12 If the item includes a pair of parentheses, the cursor will be positioned between them.

12

Degrees/Radians A calculation containing a trigonometric function can be set to operate in degrees or radians. This setting is applied to each calculation separately. The lower right corner of the Calculator indicates whether the calculation that the cursor is on is set for degrees or radians.

Keypad 1. Press F1 once to open the first menu, or twice to open the second menu. 2. Use the arrow keys to highlight the desired item and press .

To switch the setting, press F4 to open the Edit menu and select (or deselect) Radians. After you have switched the setting for a calculation, you must press or = to make the GLX reevaluate the calculation.

To select an item from the Functions menus

Mouse 1. Click Functions once to open the first menu, or twice to open the second menu. 2. Click the desired item.

Degree/Radian Indicator

Predefined Constants The symbol π is a predefined constant. The Calculator will recognize its value as 3.141592 when it is used as part of an expression or on the right side of an equation. The symbol e is a predefined constant equal to 2.718282. The capital letter E can be used interchangeably with e. Typically e is used with the exponent operator (^) to form e^, the exponential function.13

F2 [Data] Press F2 (or click [Data]) to select a data source to insert into an equation. See “Sensor-based Calculations” on page 45 for more information. The [Data] menu contains sensor measurements, manually entered data, calculations, and time.

F3 Graph Press F3 or (click Graph) to plot the equation that the cursor is on in the preview graph on the lower half of the screen. See “Graphing Equations” on page 44 for more information.

13When using the constant e, be careful not to enter it in a way that the GLX will mistake for scientific notation. See page 91 for more information.

Page 56

50

C a l c u l a t o r

F4 Edit Menu Press F4 (or click Edit) to open the Edit menu, which contains the options described below. Num Lock When Num Lock is on (which it is by default), an icon ( ) appears in the lower right corner of the screen.

Edit menu

Num Lock Icon

To turn Num Lock on or off, select Num Lock from the Edit menu.14

14

With Num Lock on, you can type only numerals (not letters or punctuation marks) with the keypad. Multiple presses of a key will not cycle through multiple characters. (That way you can type “100,” for instance, without having to wait between zeros.) The single exception is the letter E, which you can always type by pressing decimal point key ( ) twice.

Keypad 1. Press F4 to open the Edit menu. 2. Use the arrow keys to highlight the desired menu option and press ; or press the number on the keypad corresponding to the desired menu option.

EE

With Num Lock off, the keypad operates in multipress text input mode (see page 90), allowing you to enter letters and punctuation marks.

To select an option from the Edit menu

Mouse 1. Click Edit to open the menu. 2. Click the desired menu option.

It is often unnecessary to turn off Num Lock because commonly used letters and other symbols can be selected from the Functions menus, and the names of data sources can be selected from the [Data] menu. Radians Select or deselect this option to switch the highlighted calculation to radians or degrees. See “Degrees/Radians” on page 49. Clear Expression This option removes the expression that the cursor is on and leaves a blank line. Delete Expression This option removes the expression that the cursor is on and shifts up everything below it to fill in the blank line. Insert Expression This option shifts the expression that the cursor is on (and everything below it) down by one line to create a blank line at the cursor location. Data Properties Select this option to open the Data Properties dialog box for the highlighted calculation. See page 69 for more information. Print If there is a printer connected to the GLX, select Print to print the Calculator screen.15

15For more information on printing, see

“Printing” on page 91.

Output-control Calculations The functions and operators described below can be selected from the third Functions menu.16 With them, you can write expressions in the Calculator that control the GLX’s audio outputs, and the outputs of connected Digital Adapters.

16See “F1 Functions” on page 48.

Page 57

X p l o r e r

G L X

U s e r s ’

G u i d e

51

Special Functions These special functions do not directly control output, but can be useful in combination with the output-control functions.

limit(min, max, x) The limit function is used keep a varying value within a specified range. The function has three arguments: min, max, and x. •

If x < min, then limit(min, max, x) = min.

•

If x > max, then limit(min, max, x) = max.

•

If min ≤ x ≤max, then limit(min, max, x) = x.

mod(numerator, denominator) The mod function is equal to the remainder when numerator is divided by denominator. The arguments numerator and denominator can be any number (not just whole numbers). If denominator = 0, then mod(numerator, denominator) = 0. abs(x) The abs function is equal to the absolute value of its argument. random() The random function equals a randomly generated number between 0 and 1. Each time the function is evaluated, a new random value is generated. Note that the random function appears with a pair of parentheses after it, but it cannot have anything between the parentheses.

Output-control Functions The output-control functions set the output of the GLX’s audio channels and connected Digital Adapters. The output-control functions work only when data collection is in process. Each function must be used as part of a sensor-based calculation (the calculation must include data from a sensor or time). Any property of the audio output that is not specified in the Calculator will be determined by the setting in the Output screen (see page 39). In the Functions menu, the names of these functions are abbreviated to outstate, outswitch, outfreq, and outvolume.

outputstate(GLXPort, AdapterChannel, state) Use the outputstate function to switch on or off a Digital Relay connected through a Digital Adapter.17 The first argument of the function, GLXPort, can equal 1, 2, 3, or 4; it identifies the port that the Digital Adapter is connected to. The second argument, AdapterChannel, can equal 1 or 2 and identifies which channel of the adapter the Digital Relay is connected to. The third argument, state, can equal any number and determines whether the relay is OFF or ON. •

If state = 0, then the relay is OFF.

•

If state ≠ 0, then the relay is ON.

outputswitch(Channel, state) Use the outputswitch function to turn on or off the left or right audio output channel.18 The first argument, Channel, can equal 1 (for left) or 2 (for right) and identifies which audio channel is to be controlled. The second argument, state, can equal any number and determines whether the audio output is OFF or ON. •

If state = 0, then the audio output is OFF.

•

If state ≠ 0, then the digital output is ON.

17

The Digital Relay is PASCO part CI-6462. The Digital Adapter is PASCO part PS-2159.

See “Relay Control” on page 67 for instructions on connecting and configuring the adapter.

18Whether the output is played through the output port (to a pair of headphones or amplified speakers) or through the GLX’s built-in speaker depends on the Output setting in the Output screen (see page 40).

Page 58

52

C a l c u l a t o r outputfreq(Channel, frequency) Use the outputfreq function to set the frequency of the audio output signal.18 The first argument, Channel, can equal 1 (for left) or 2 (for right) and identifies which channel is to be controlled. The second argument, frequency, sets the frequency, in Hz, of the output signal. The frequency can be set between 250 and 5000 Hz for the built-in speaker, or between 60 and 5000 Hz for headphones or external speakers. outputvolume(volume) Use this function to set the loudness of the output signals.18 The argument of the function can be set between 0 (for no output) and 10 (for the loudest possible output). The function controls both audio channels together.

Logic Operators and Functions A logic function has two possible values: 0 and 1. A logic operator (< or >) is used to build an expression that can have a value of 0 or 1. Less Than and Greater Than If an expression such as a < b is true, then it equals 1. If the expression is false, then it equals 0.

inrange(min, max, x) This function has three arguments: the first two, min and max, define the upper and lower limit of a range, and the third, x, is an input value to be compared with that range. If min ≤ x ≤max, then the function equals 1. If x < min, or x > max, then the function equals 0. and(a, b) This function equals 0 if either of the arguments equals 0; otherwise the function equals 1. or(a, b) This function equals 0 if both of the arguments equal 0; otherwise the function equals 1. not(x) This function equals 1 if the argument equals 0; otherwise the function equals 1.

Audio Temperature Indicator In this example, the GLX is programed to emit a sound when the temperature exceeds 30 °C. The frequency of the sound increases as the temperature increases. Connect a temperature sensor to the GLX. In the Calculator, enter these two expressions:

outputswitch(1,[Temperature (°C)]>30) outputfreq(1,[Temperature (°C)]*10) Select the outputswitch and outputfreq functions from the Select the [Temperature (°C)] measurement from the F2

Audio Temperature Indicator Example

F1

Functions menu. [Data] menu.

Press to start data collection. Place the temperature sensor in warm water. Then allow it to cool again. When the temperature reaches 30 °C, the GLX emits a tone at 300 Hz. As the temperature rises, the frequency of the tone rises.

Page 59

X p l o r e r

G L X

U s e r s ’

G u i d e

53

No tes Sc ree n Use the Notes screen to record experiment instructions, information about the sensors and displays that you have set up, notes on recorded data, or any other text information.

To Open the Notes screen From the Home Screen, do one of the following: use the arrow keys to highlight the Notes icon, then press

; or click the Notes icon. The Notes icon on the Home Screen

Entering, Reading, and Printing Text Notes Enter text via the GLX keypad or a connected USB keyboard. See “Multipress Text Input Mode” on page 90 or “Using a USB Keyboard” on page 90.

To input a single capital letter, first press F1 to turn on Shift. To input all capital letters, turn on Caps Lock by pressing F2 . To disable multipress text input mode (for typing just numbers), turn on Num Lock by pressing F3 .

19 To select an option from the Notes menu

F1

F2

F3

F4

The GLX can store multiple notes pages. To start a new page, press the Notes menu and select New Page.19

F4 to open

If more than one page exists, you can also press F4 to select a previously created page for viewing and editing, or to delete the currently displayed page. The page number of the visible page and the total number of pages are indicated in the lower right corner of the screen. To print the currently displayed page on a connected printer, press select Print. To print all notes pages, select Print All.

F4

Keypad 1. Press F4 to open the Notes menu. 2. Use the arrow keys to highlight the desired menu option and press ; or press the number on the keypad corresponding to the desired menu option. Mouse 1. Click the page number in the lower right corner to open the Notes menu. 2. Click the desired menu option.

and

For more information, see “Printing” on page 91.

Click here or Press F4 The Notes menu

Page 60

54

S t o p w a t c h

Sto pw at ch With the Stopwatch screen, you can use the GLX like a conventional stopwatch.

To Open the Stopwatch From the Home Screen, do one of the following: use the arrow keys to highlight the Stopwatch icon, then press

; or click the Stopwatch icon. The Stopwatch icon on the Home Screen

Timing with the Stopwatch The numbers displayed on the stopwatch indicate elapsed time in minutes and seconds.

minutes

F1

Press

F1

F2 to start timing. Press

When timing is stopped, press 00:00.00 seconds

F1

F2 again to stop timing. to set the displayed elapsed time back to

Page 61

X p l o r e r

G L X

U s e r s ’

G u i d e

55

Cha p te r 3 : Se t t ing s an d F il es Sen sor s S cr een In many cases, the sensor set-up process requires nothing more than simply plugging in a sensor. However, if you would like to change any of the sensor settings, or configure a sensor that you have not physically plugged in, or change the mode of data collection, go to the Sensors screen. Also use the Sensors Screen to configure the GLX’s microphone as a sound sensor.

Sensors screen

To Open the Sensors Screen From the Home Screen, do one of the following: press

F4

, the function key below the Sensors icon;

use the arrow keys to highlight the Sensors icon and press

; or The Sensors icon on the Home Screen click the Sensors icon. From anywhere in the GLX environment, you can always open the Sensors Screen with the shortcut + F4 .

Working with Multiple Sensors An icon for each sensor connected to the GLX appears at the top of the screen.1 A box around one of the icons indicates the selected sensor. Use the left and right arrow keys (or mouse) to select the sensor that you want to set up. The settings for the selected sensor appear in the lower part of the screen. Multiple Sensors Selected Sensor

Top portion of the Sensors screen; this GLX is connected to an acceleration sensor and a force sensor

1

In some cases, an icon for a sensor that is not physically connected to the GLX appears in the Sensor screen. Such icons are designated with .

Page 62

56

S e n s o r s

S c r e e n

Sensor Settings To change any of the settings, use the arrow keys to highlight the settings and press . If you are using a mouse, click the desired setting. Sample Rate Unit Select Sample Rate Unit2 to choose how the sampling rate will be measured. The choices are samples per second; or seconds, minutes, or hours (time between samples). Number of samples per second Time between samples 3

Sample Rate Select Sample Rate to set the sensor’s rate of data collection (measured in the units selected above).

2 To select Sample Rate Unit

Keypad 1. Use the arrow keys to highlight Sample Rate Unit 2. Press to open the menu. 3. Use the arrow keys to highlight the desired units and press ; or press the number on the keypad corresponding to the desired units. Mouse 1. Click Sample Rate Unit to open the menu. 2. Click the desired units. 3

To select Sample rate

Keypad 1. Use the arrow keys to highlight Sample Rate. 2. Press to open the menu. 3. Use the arrow keys to highlight the desired rate and press ; or press the number on the keypad corresponding to the desired rate. or +

Open the Sampling Rate menu or change the sampling rate with + and

Reduce/Smooth Averaging This feature is a type of oversampling. You can use it to: • reduce what would be a large data set to a manageable size,

• smooth noisy data,

• improve the effective resolution of a sensor.

1. Use the arrow keys to highlight Sample Rate. 2. Press + or to increase or decrease the value.

Mouse 1. Click box to the right of Sample Rate to open the menu. 2. Click the desired rate.

4To select Reduce/Smooth Averaging

Select Reduce/Smooth Averaging and choose the number of points to be averaged.4 The number of points represents the factor by which the effective sampling rate, data set size and noise level are reduced.

No averaging

2-point averaging

10-point averaging

Keypad 1. Use the arrow keys to highlight Reduce/Smooth Averaging. 2. Press to open the menu. 3. Use the arrow keys to highlight the desired number of points and press ; or press the number on the keypad corresponding to the desired number of points. Mouse 1. Click the box to the right of Reduce/ Smooth Averaging to open the menu. 2. Click the desired number of points.

Page 63

X p l o r e r

G L X

U s e r s ’

G u i d e

57

Zero Automatically On Start This setting appears for sensors that support zeroing (such as acceleration, rotary motion, and drop counter sensors). The three choices are “On,” “Off,” and “Zero Now.” When “On” is selected (which it is by default), the sensor measurement is adjusted with each new data run to make the first sample zero. When “Off” is selected, the measurement is not automatically zeroed. When you select “Zero Now,” the measurement is adjusted to make present value zero, but it will not be re-zeroed at the start of data collection. Measurements Each of the sensor’s measurements have a “Visible” or “Not Visible” tag. Visible measurements appear in the data source menus of the display screens. Select a measurement to change its setting from “Visible” to “Not Visible,” or vice-versa.5 A measurement set to “Not Visible” does not appear in the displays’ data source menus; however, it is still accessible by selecting “More” from the menu. See “Expanding the Data Source Menu” on page 89.

5

To change the visibility of a measurement

Keypad 1. Use the arrow keys to highlight the measurement. 2. Press . Mouse Click on the word “Visible.”

Sensors Function Keys F1 Mode The Mode menu contains options for how the GLX collects data. When you select a sampling mode6, that mode is applied to all sensors.

F1

Modes menu

Continuous Sampling Continuous Sampling is the default and most commonly used mode. In this mode, when you press , the GLX starts to collect and record data from every sensor at a constant rate. Data collection stops when you press again.

6To select a sampling mode

Keypad 1. Press F1 to open the Mode menu. 2. Use the arrow keys to highlight the desired menu option and press ; or press the number on the keypad corresponding to the desired menu option. Mouse 1. Click Mode to open the menu. 2. Click the desired menu option.

The rate of data collection is determined separately for each sensor. See “Sample Rate” on page 56 for more information.

Manual Sampling Select Manual Sampling from the Mode menu to record a series of single manually triggered samples. See page 60 for instructions on setting up and using manual sampling.

F2 Data Properties To open the Data Properties dialog box for a sensor measurement, first use the arrow keys to highlight the measurement, then press F2 . See page 69 for a description of the Data Properties dialog box.

To open the Properties dialog box, highlight a measurement before you press F2

Page 64

58

S e n s o r s

S c r e e n

F3 Microphone The Microphone menu contains options for setting how the GLX uses its built-in microphone. The selected option is indicated by a check mark ( ) appearing next to it in the menu.7

7To select an option from the

Microphone menu

Keypad 1. Press F3 to open the menu. 2. Use the arrow keys to highlight the desired menu option and press ; or press the number on the keypad corresponding to the desired option. Mouse 1. Click Microphone to open the menu. 2. Click the desired option.

Microphone

Sound Sensor When Sound Sensor is selected, the GLX’s microphone becomes a sensor that collects data showing the waveform of sound. The sound sensor appears in the upper part of the Sensors screen, just like any other sensor. Like other sensors, the Sound Sensor settings include Sample Rate Unit, Sample Rate, and Reduce/Smooth Averaging; however you typically would not change any of these settings because the sample rate is automatically set by the Graph in Scope Mode. The Sensitivity setting sets the gain of the Sound Sensor.8 For very loud sounds set the Sensitivity lower; for softer sounds, set it higher. To make the Sound Sensor automatically adjust its sensitivity based on the loudness of the sounds that it detects, set the Sensitivity to Automatic. The Sound Sensor is most commonly used with the Graph display in Scope mode. Press and F1 together to go to the Graph display. Then press F4 to open the Graphs menu, and press 3 to select Scope mode. Press . Whistle or hum; you will see sound wave in the Graph. (See page 22 for more information on Scope mode.) wxyz

Sound Level When Sound Level is selected, the GLX’s microphone measures the loudness of sound in decibels (on the dBA scale). The Sound Level sensor operates at a much lower sampling rate than the Sound Sensor. Like most other sensors, you would normally use the Sound Level sensor in continuous or manual sampling mode (see page 57), not in Scope mode. Audio Notes With this default setting, the microphone is configured to record the audio portion of data notes (see “Data Annotation” on page 25). If you have previously recorded sound-sensor or sound level data, selecting Audio Notes is equivalent to unplugging the Sound or Sound Level sensor. The GLX will preserve any sound data sets that have been recorded, but it will not collect new data from the microphone.

8To change the Sensitivity

Keypad 1. Use the arrow keys to highlight Sensitivity. 2. Press to open the menu. 3. Use the arrow keys to highlight the desired setting and press ; or press the number on the keypad corresponding to the desired setting. or 1. Use the arrow keys to highlight Sensitivity. 2. Press + or to increase or decrease the value.

Mouse 1. Click box to the right of Sensitivity to open the menu. 2. Click the desired setting.