The text of a manual · part 17 of 17
Xplorer GLX Users' Guide: Part 2: Sample Activities, pages 147 to 152
Pages 147 to 152 of 152, from Xplorer GLX Users' Guide
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Pasco PS-2002
Page 147
X p l o r e r
G L X
U s e r s ’
G u i d e
I nd ex A abs function 51 AC power 6 Analog Adapter 59 and() function 52 Annotation 25 Area Tool 20 Audio notes 25 Audio output 39, 50 Audio Settings 87 Audio temperature indicator, example 52 Automatic display launching 86 Automatic file opening 86 Automatic shut down 8, 85 Autoscale 16 Averaging 56 B Back light 6, 86 Backup GLX (to USB storage device) 83 Battery and file storage 94 capacity 95 charging 93 gauge 11 internal disconnection 94 reconditioning 95 replacement 95 Bits per sample (audio recording) 87 C Calculator 41 Calibration 71 multiple-measurement 73, 77 navigating in dialog box 73 one-point offset 73 one-point slope 72 step-by-step instructions 75 two-point 72 Cell-selective manual sampling 60 Collision Timer 66 Computer connecting GLX to 7 DataStudio 99 file transfer to 100, 104 GLX Simulator 103 using GLX with 99 Connected lines in Graph 22 Continuous Sampling mode 57 Contrast 6 Coordinates in Graph 16 Copying a file 81 Create Calculation from Linear Fit 22 D Data annotation 25 Data Cursor 16, 22 Data Files screen 78 Data notes 25 Data Properties 69, 90 Data source menus 89 DataStudio 99 Date 85, 87
Date/Time (in Table) 31 Deep sleep mode 94 Deleting calculations 50 data runs 16 files 80 Graph pages 25 sensors 59 Table cells 30 Delta Tool 18 Derivative 20 Digital Adapter 67 Digital Input timer 67 Digital output 51, 67 Digits display 37 E Editing data 34 EE for Exponent settings 70 Engineering notation 70 Equipment included with GLX 4 Excel, export data to 32 Export All Data (as tab-delimited text) 32 F File transfer between GLXs 84 to and from computer 100, 104 to and from USB storage device 83 Files 78 copying 81 deleting 80 moving 81 opening 80 renaming 81 saving 80, 81 size limits 82 Firmware update 93 Flash drive (USB) for file storage 83 for firmware update 93 Flash memory 82 Free Fall Adapter timer 65 G General Counting timer 66 GLX settings 85 GLX Simulator 103 GLX storage 94 GLX-to-GLX File Transfer 84
Graph display 13 Area Tool 20 Autoscale 16 Delta Tool 18 Derivative 20 Graphs menu 22 Linear Fit 19 pages 24 Scale/Move 16, 17 Scope mode 22 Slope Tool 19 Smart Tool 18 Statistics 19 Swap Cursors 21 Tools menu 17 Trigger 20 Two Graphs mode 24 Two Measurements mode 23 Two Runs mode 24 Zoom Tool 21 Graphing equations 44 manually entered data 36 greater than operator 52 H Hardware maintenance 93 Headphones 7, 40 Home Screen 9 I inrange function 52 K Keyboard 7, 90 L Language 86 less than operator 52 limit function 51 Linear Fit 19 Linear Fit Cal 22 Lock Run Selection 31 M Maintenance 93 Manual sampling 60 Manually entered data 32, 36 Mapping software, export data to 32 Measurements name 69 unit 69 visibility 57 Memory Gauge 11 Memory types 82 Meter display 38 Mic Input Volume 87 Microphone 58 in DataStudio 102 mod function 51 Mouse 7 Moving a file 81 Multiple-measurement alignment 73, 77
141
Page 148
142
I n d e x
Multipress text input 90 N Name of GLX 85 New Page Graph 24 Notes 53 not() function 52 Note Editor dialog box 27 Notes (data annotation) 25 Notes screen 53 Numeric styles 70 O On/Off button 6 One-point offset calibration 73, 77 One-point slope calibration 72, 76 Opening a file 80 or() function 52 Oscilloscope emulation 22 Output Device (audio) 87 Output screen 39 Output-control calculations 50 outputfreq function 52 outputstate function 51 outputswitch function 51 outputvolume function 52 P Page Graph 24 Notes 53 PASPORT sensors 6 Photogate and Pendulum timer 65 Photogate and Picket Fence timer 64 Photogate Timing 66 Power button 6 Power source 6 Printing 91 Q Quick Start 5 R RAM (random-access memory) 82 random function 51 Recording modes 57 Recording Status icons 11 Reduce/Smooth Averaging 56 Relay control 67 Renaming data run 16 file 81 Resetting 96 Restore (from USB storage device) 83 S Sample activities 105 Sample rate (audio recording) 87 Sampling modes 57 Sampling rate 56 Saving a file 80, 81 ScienceWorkshop sensors 59, 67 Scientific notation 70, 91 Scope mode 22 Screen contrast 6, 86 Screen mirroring and capture 104 Sensor Auto-Display 86
Sensors calibration 71 multiple 55 removing 59 sampling rate 56 ScienceWorkshop 59, 67 set-up 55 Sensors screen 55 Settings screen 85 Set-up options for GLX 6 Shut down 7 automatic 8 manual 7 resuming after 8 Signal output 7, 39, 50 Significant figures 70 Sleep between samples 8 Slope Tool 19 Smart Pulley timer 65 Smart Tool 18 Sound level sensor 58 in DataStudio 102 Sound sensor 58 in DataStudio 102 Speaker Configuration in Audio Settings dialog box 87 in Output Screen 40 Speaker Volume 87 Speakers 7, 40, 87 Spreadsheet, export data to 32 Start condition 20 Startup Action 86 Statistics in Graph 19 in Table 29 Sticky Start 8 Stop condition 21 Stopwatch 54 Storage of GLX 94 Swap Cursors 21 T Table display 28 Edit menu 30 editing 34 manual data entry 32 scrolling 29, 35 Statistics menu 29 Tables menu 31 Temperature probe 6 Temperature, GLX operating range 97 Text data 33 Text data notes 53 Text input via keypad 90 Time 85, 87 Time data in Table 31 Time of Flight timer 66 Timing screen 62 Top Bar 11 Trigger 20 Two Graphs mode 24 Two Measurements mode 23 Two Runs mode 24 Two-point calibration 72, 75 U Update firmware 93 USB flash drive for file storage 83 for firmware update 93
USB storage device for file storage 83 for firmware update 93 V Version 87 Voltage probe 6 Z Zero |Value| 70 Zero Automatically On Start 57 Zoom Tool 21
Page 149
X p l o r e r
G L X
Sh o rt cut Su mm ary These keys and key combinations work from any screen in the GLX environment. Start and stop data collection Backlight
+
Contrast
+
Graph
+
F1
Table
+
F2
Calculator
+
F3
Sensors
+
F4
Home Screen Next Screen
+
Previous Screen
+
Use these shortcuts when working in the Graph Screen. Swap Cursors
Esc
+
Toggle Active Data
Esc
+
Õ
U s e r s ’
G u i d e
143
Page 150
Page 151
PASCO scientific XplorerGLX Font Software PRODUCT LICENCE AGREEMENT Read this license agreement carefully before signing it. You may use this PASCO Product only if you agree to the following terms and conditions. If you do not agree to the following terms and conditions, you must not use the PASCO Product. The following are the terms and conditions to which you agree upon when opening the package: 1. The PASCO Product contains font software which generates typeface designs (“Font Software”) You may not alter Font Software for the purpose of adding any functionality which such Font Software did not have when delivered to you as part of the PASCO Product. You may not embed Font Software into a document which is distributed as a commercial product in exchange for a fee or other consideration (For example, End-Users shall not embed Font Software into an electronic book that is offered to the public for a fee). 2. The PASCO Product may be used with your computer only and may not be reformatted or decompiled for any purpose. The PASCO Product can only be used for your “Internal Use” and not for resale, sublicensing, or further distribution. As used herein, “Internal Use” shall mean use in the course of your customary and ordinary business. Internal Use shall not include any distribution whatsoever of the PASCO Product or any component thereof except that you may electronically distribute Internal Use documents created by the PASCO Product in a static graphic image or in an embedded electronic document which is distributed in a format that permits only the viewing and printing (and not the editing, altering, enhancing, or modifying) of such static graphic image or embedded document. Internal Use shall not include any use of the PASCO Product by entities that are neither your authorized employees nor your authorized agents. All such employees and agents shall be notified by you as to the terms and conditions of this End-User Agreement and shall agree to be bound by it. As used herein. “Internal Use” shall occur when an individual is able to give commands (whether by keyboard or otherwise) that are followed by the Font Software, regardless of the location in which the Font Software resides. 3. The PASCO Product may not be used to create any electronic document in which Licensed Type Software is embedded in a document in a format, which may be edited, altered, enhanced, or modified by the recipient of such document. 4. The PASCO Product may not be duplicated or copied except for one copy for archival purposes, program error verification or to replace defective media. All copies must remain in your possession and bear the copyright notices contained on the original except that an archival copy may be placed for safekeeping in the hands of a third party that otherwise has no right to use such copy. All archival copies placed in hands of a third party must contain all proprietary notices set forth on the original PASCO Product. 5. No copies of the PASCO Product may be produced for any purpose other than those purposes expressly permitted in paragraph 2 above. 6. This license does not transfer any right, title, or interest in the PASCO Product to you except as specifically set forth herein. You are on notice that PASCO claims protection of this software product under copyright laws. The PASCO Product may have been developed by an independent third party software supplier, which holds copyright or other proprietary rights to its software product. You may be held responsible by this supplier for any infringement of such rights by you. 7. PASCO reserves the right to terminate this license upon breach. In the event of termination, you will be required to return all copies of this product or provide PASCO with a certificate of destruction of all copies. 8. In the event you modify the PASCO Product or include it in any other software program, upon termination of this license, you agree either to remove the software product or any portion thereof from the modified program and return it to PASCO or to provide PASCO with a certificate of destruction thereof. 9. If this product is acquired under the terms of a (i) GSA contract - use, reproduction or disclosure is subject to the restrictions set forth in the applicable ADP Schedule contract, (ii) DOD contract - use, duplication or disclosure by the Government is subject to restrictions set forth in subparagraph (c)(1)(ii) of 252.277-7013; (iii) Civilian agency contract use, reproduction, or disclosure is subject to 52.277-19(a) through (d) and restrictions set forth in the accompanying End User Agreement. All rights reserved under the copyright laws of the United States, United Kingdom and elsewhere. MONOTYPE IMAGING Ltd, Unit 2 Perrywood Business Park, Salfords, Surrey, RH1 5DZ, England.