Page 129

X p l o r e r

G L X

U s e r s ’

G u i d e

123

Act iv i ty 6 : Vo lta ge v ersu s Res i s ta nc e Equipment

Quantity

Xplorer GLX

1

Voltage Probe

1

Resistors, 1000 Ω

5

Battery and Battery Holder (“AA,” “C,” “D,” or similar)

1

Short Alligator Clip Leads

6

Background F

In this experiment, you will construct the circuit pictured to the right and measure the voltage (relative to the negative terminal of the battery) at points A through F. For each point in the circuit, the GLX will record the measured voltage (V) and the total resistance across which the voltage was measured (r).

1000 W E 1000 W

Sketch a prediction of the graph of V versus r. Explain your prediction in terms of what you know about

D

+

1000 W battery -

• how current flows through the circuit;

• the relationship between voltage, current, and resistance; and

• the total resistance of two or more resistors in series.

C 1000 W B 1000 W A

Before You Begin Start a new experiment on the GLX. 1.

Press to go to the Home Screen.

2.

Use the arrow keys to highlight the Data Files icon and press the Data Files screen.

3.

Press

4.

When the GLX asks if you would like to save the previous file, press to save or F2 not to save.

F4 to open the Files menu and press 1 pqrs to open to select New File. F1

Procedure Equipment Set-Up 1.

Using the battery, battery holder, resistors, and alligator clip leads, construct the circuit pictured on the previous page.

Page 130

124

V o l t a g e

2.

v e r s u s

R e s i s t a n c e

Lay out the circuit on a piece of paper so you can label the parts of the circuit. Label points A through F and the positive and negative terminals of the battery.

GLX Set-Up 1.

Connect the voltage probe to the GLX. a)

Connect the voltage probe to the voltage port on the left side of the GLX.

b) If there are other sensors connected to the GLX, remove them. 2.

Configure the GLX for manual sampling. a)

Press screen.

b) Press to return to the Home Screen; press

F1 to open the Mode menu; press

2tuv

F4 to open the Sensors to select Manual.

The Data Properties dialog box for the manually entered resistance data will open. c)

With Measurement Name highlighted, press .

F1

; type “r” and press d) Press the down arrow key to highlight Measurement Unit. Press type “ohm”, and press .

,

Enter the Measurement Name and Unit.

F1 e)

3.

F2

Press F1 to approve these data properties and close the Data Properties window.

Prepare the Graph to plot voltage versus resistance. a)

Press to return to the Home Screen; press

F1 to open the Graph.

The Graph will be automatically set up for voltage versus time. In the next step, you will select resistance (instead of time) for the horizontal axis. b) Press to turn on the highlight; press the down arrow key to highlight “Time.” c)

Press to open the data source menu.

d) In the data source menu, use the arrow keys to highlight “r” and press . Select resistance for the horizontal axis

Page 131

X p l o r e r

G L X

U s e r s ’

Graph prepared to plot V vs. r

Data Collection 1.

Press

. The GLX is now measuring voltage, but it is not recording data.

2.

Connect the black lead of the voltage probe to the negative terminal of the battery.

3.

Place the red lead of the probe in contact with the circuit at point A.

4.

Press

5.

The GLX will prompt you to enter r, the total resistance across which the voltage is measured. (For point A, r = 0.) Type the value of r and press F1 .

6.

Repeat steps 3, 4, and 5 for points A through F.

7.

When you are finished recording data, press to record a single voltage measurement.

F1

.

Analysis F1

1.

Press

2.

Does your data appear to agree with your prediction?

3.

Apply a linear fit to the graph and find the slope. a)

Press to automatically scale the Graph.

F3 to open the Tools menu; press 5 jkl to select Linear Fit.

b) What is the slope (including units) of the best-fit line? slope = __________ c)

What physical quantity does the slope represent?

F2

G u i d e

125

Page 132 read from a scan by OCR; it may hold reading errors

126 Voltage versus Resistance

Page 133

X p l o r e r

G L X

U s e r s ’

G u i d e

127

Act iv i ty 7 : I nd uc e d E le c tr omo t ive F o rce Equipment

Quantity

Xplorer GLX

1

Voltage Probe

1

Coil1

1

1Use a coil with a few hundred turns,

Bar Magnet

1 such as the one included with PASCO part CI-6512.

Background When a permanent magnet passes through a coil, the changing magnetic flux induces and electromotive force (EMF) or voltage in the coil. According to Faraday’s Law of Induction: dφ ε = – N ----dt where ε is the induced EMF, N is the number of turns in the coil, and dφ ⁄ dt is the rate of change of magnetic flux through the coil. In this activity, you will drop a magnet through a coil while the GLX records and graphs the induced EMF versus Time. The area under the under the curve represents the total change in flux.

Before You Begin Start a new experiment on the GLX. 1.

Press to go to the Home Screen.

2.

Use the arrow keys to highlight the Data Files icon and press the Data Files screen.

3.

Press

4.

When the GLX asks if you would like to save the previous file, press to save or F2 not to save.

F4 to open the Files menu and press 1 pqrs to open to select New File. F1

Procedure Equipment Set-Up 1.

Clamp or mount the coil so that the magnet can be dropped through it.

2.

Place something soft under the coil to prevent the magnet from breaking.

3.

Connect the voltage probe to the coil so that it will measure the voltage across the coil.

Page 134

128

I n d u c e d

E l e c t r o m o t i v e

F o r c e

GLX Set-Up 1.

2.

Connect the voltage probe to the GLX. a)

Connect the voltage probe to the voltage port on the left side of the GLX.

b)

If there are other sensors connected to the GLX, remove them.

Set the sampling rate to 200 Hz. a)

Press b) Press c)

to return to the Home Screen. F4 to open the Sensors screen.

Press the down arrow key to highlight Sample Rate.

d) Press + repeatedly to set the Sample Rate to 200 Hz. 3.

Open the Graph display. a)

Press to return to the Home Screen.

b) Press F1 to open the Graph display. The display will be automatically set up to graph Voltage versus Time.

Data Collection 1.

Hold the magnet about 2 cm above the coil.

2.

Press

; drop the magnet through the coil; press again.

Analysis 1.

Scale the Graph. a)

Press

F1 to automatically scale the Graph.

b) Press F2 to enter Scale mode, press F2 again to enter Move mode. Use the left and right arrow keys in both modes to zoom in on the positive and negative peaks. See page 16 for detailed instructions on using Move and Scale modes.

2.

Find the area under the first peak. a)

Press

F3 to open the Tools menu; press

6mno to select the Area Tool.

Place the dashed box around the first peak

Page 135

X p l o r e r

G L X

U s e r s ’

G u i d e

129 b) Use the left and right arrow keys to move the right side of the dashed box to the right side of the first peak. c)

Hold Esc and press dashed box.

Õ to swap the cursor to the other side of the d) Use the left and right arrow keys to move the left side of the dashed box to the left side of the first peak. See page 20 for detailed instructions on using the Area Tool.

Area under the first peak = _________________ (include sign and units) 3.

Find the area under the second peak. Repeat step 2 to position the dashed box around the second peak. Area under the second peak = _________________

4.

Compare the incoming flux (area under the first peak) to the outgoing flux (area under the second peak).

5.

Why is the outgoing peak higher than the incoming peak?

6.

Why are the peaks opposite in direction?

Place the dashed box around the second peak

Page 136 read from a scan by OCR; it may hold reading errors

130 Induced Electromotive Force

Page 137

X p l o r e r

G L X

U s e r s ’

G u i d e

131

Act i v i ty 8 : C a pac i t o r D i s c h ar ge Equipment1

Quantity

Xplorer GLX

1

Voltage Probe

1

Capacitor (between 0.015 and 1 F)

1

Resistor (between 100 and 1000 Ω)

1

Battery and battery holder (“AA,” “C,” “D,” or similar)

1

Alligator Clip Leads

4

1

Use separate electronic components or the PASCO EM-8678 Charge/Discharge board, which includes a capacitor, resistors, and battery holder.

Background

C

R

V

In the circuit pictured above, the rate at which the voltage, V, decreases is directly proportional to the voltage. Mathematically, this can be written: dV ------ = – τV dt

(eq. 1)

where dV/dt is the rate of voltage change, and τ is a constant greater than 0 known as the Capacitive Time Constant. The negative sign indicates that the voltage decreases over time. Equation 1 can be rewritten: V ln ----- = – τt V0

(eq. 2)

where V is the voltage at any given time, t; and V0 is the voltage at t = 0. In this experiment, you will create a circuit like the one in the diagram. The GLX will measure and graph voltage over time as the capacitor discharges. From the collected data, you will determine the capacitive time constant, τ, of your circuit.

Before You Begin Start a new experiment on the GLX. 1.

Press to go to the Home Screen.

2.

Use the arrow keys to highlight the Data Files icon and press the Data Files screen.

3.

Press

F4 to open the Files menu and press 1 pqrs to open to select New File.