Page 95
X p l o r e r
G L X
U s e r s ’
Cha p te r 4 : Na vi ga t ion an d I n pu t Da ta S ou rce M enu s The axes of the Graph, the columns of the Table, the sections of the Digits display, and the Meter each have a data source field, which you access to choose what data to display. Selecting any of these data source fields opens a data source menu containing a list of all available data sources.
Identifying a Data Source •
In one of the simplest cases - a GLX with one single-measurement sensor connected, and no calculations or manually entered data - the data source menu contains two items, as illustrated to the right. In this example, there is only one data source option, so it is selected automatically. Selecting the other option in the menu, Data Properties, opens the Data Properties dialog box for the selected measurement. See “Accessing Data Properties” on page 90.
•
In this example, the GLX is connected to two single-measurement sensors: a Temperature Sensor and a Relative Pressure Sensor. There are two data sources to choose from. The selected data source has a check mark next to it. The two data sources are from two different sensors, so each has a different icon.
•
Certain sensors make more than one measurement. The data source menu pictured here is from a GLX connected to a Pressure/Temperature Sensor. Note that the two data sources have the same icon, indicating that they both come from the same sensor.
•
The menu pictured to the right is from a GLX connected to two sensors: a Temperature Sensor and pH/ORP/ISE/Temperature Sensor. The pH/ORP/ ISE/Temperature Sensor makes several measurements, one of which is Temperature. There are two data sources named “Temperature,” one from the pH/ORP/ISE/Temperature Sensor and one from the Temperature Sensor. You can tell which sensor each temperature measurement is from by looking at the icons next to the measurement names.
Expanding the Data Source Menu •
The menu pictured to the right is from a GLX connected to a Motion Sensor. The Motion Sensor makes three measurements: Position, Velocity, and Acceleration. Only one measurement, Position, is visible. The “More” option that appears with a Motion Sensor icon indicates that other measurements are available from that sensor, but are not shown. Select “More” to see the other available measurements.
•
In the menu pictured to the right, two sensors are present that each have hidden measurements. There are two “More” options, one for each sensor. They can be distinguished by their different icons.
G u i d e
89
Page 96
90
M u l t i p r e s s
T e x t
I n p u t
M o d e
Accessing Data Properties Selecting the Data Properties option from a data source menu opens the Data Properties dialog box for the selected measurement. In this example, the Data Properties for Relative Pressure would open. To access the Data Properties of another measurement, first select that measurement from the data source menu, then open the menu again and select Data Properties. For information on the Data Properties dialog box, see page 69.
Mult ipr ess Text In put Mode Multipress text input is used to enter numbers and letters through the keypad of the GLX. Each of the GLX’s input keys has a number and several letters or punctuation marks printed on it. In multipress mode, repeatedly pressing a key will cycle through these characters. The 7 key ( 7 ) will cycle through punctuation marks, not all of which are printed on the key. The characters in the cycle are: ?!
7?!@(),:;&~%#<> The 0 key ( 0 ) cycles through two characters: 0 and a space. The decimal point key ( ) cycles through two characters: a period (or decimal point) and E, which is used often in scientific notation. EE
Us ing a U SB K eyb oar d For most users, text entry is faster and easier with a USB keyboard1 connected to the GLX. A keyboard also allows the input of capital letters in areas of the GLX environment where Shift and Caps Lock are not available. Most keys on the GLX’s keypad have an obvious equivalent key on an attached USB keyboard. The less obvious keyboard equivalents are shown in the table below. GLX Key
USB Keyboard Equivalent Enter and Return Home F5 F6
Õ
Backspace and Delete
X
* (asterisk)
1PASCO part PS-2540 or PS-2541
Page 97
X p l o r e r
G L X
U s e r s ’
G u i d e
91
Sci ent if ic N otati on The GLX displays very large and very small numbers using scientific notation. You can also input any number using scientific notation. On the GLX, the letter E, when it is placed between two numbers (with no spaces) is interpreted as meaning “times 10 raised to the power of….” The letter E can always be input by pressing the decimal point key ( even when the GLX is not in multipress text input mode.
EE
) twice,
Below are some examples of scientific notation and their normal equivalents.
5E2 = 500 1.234E5 = 123400 56.789E1 = 567.89 6.518E-3 = 0.006518 A lowercase e can be used interchangeably with uppercase E:
4.35e5 = 4.35E5 = 435000 A number expressed in scientific notation must not have a space adjacent to the E. The number to the left of the E can contain a decimal point, but one is not required. The number to the right of the E must not contain a decimal point.
Pr in tin g The Graph, Table, Calculator, Sensors, Output, Notes, Meter, and Stopwatch screens can all be printed on certain models of printers2 connected to the GLX’s USB port. In these screens, select the print command (or commands) from the F4 menu. To install a printer on the GLX, simply connect it to the GLX’s USB port using the cable that came with your printer. Drivers for compatible printers are factory installed on the GLX and updated whenever the GLX receives a firmware update (see page 93).
2The list of compatible printers is contin- ually increasing as new printer models become available. For an up-to-date list of compatible printers, visit www.pasco.com or contact PASCO technical support at: support@pasco.com or (916) 786-3800 or (800) 772-8700
Page 98
92 Printing
Page 99
X p l o r e r
G L X
U s e r s ’
G u i d e
93
Cha p te r 5 : Ha rdw are Ma int e na nc e an d O pe ra ti on Fir mw ar e U pd ate From time to time, PASCO issues a free update to the firmware that runs on the GLX. Updates include new and improved features and bug fixes. Send in the registration card that you received with your GLX, or register at www.pasco.com/glx to be notified of new updates. To check the version of firmware currently installed on your GLX, open the Settings screen (see page 85) and press F4 . You can always download the latest update from www.pasco.com/glx. Follow the instructions at the website to download the update to your computer or a USB flash drive. When you download the firmware update, also download the latest revision of this Users’ Guide from the same web page. Installing updates may delete files saved in the RAM and Flash folders of the GLX. Transfer stored files to your computer before upgrading the GLX. (See “Transferring Files” on page 100.)
F4
Version numbers displayed in the Settings screen
Updating from a Computer Once the update is on your computer, connect the GLX to the USB port and run DataStudio. When DataStudio detects a GLX running an older firmware version, it will give the option of upgrading that GLX. (See “GLX with DataStudio” on page 99.)
Updating from a USB Flash Drive1 Connect the USB flash drive containing the update to the GLX’s USB port. Open the Data Files screen (see page 78). Press F4 to open the Files menu and select Upgrade GLX Firmware.
1To update the firmware from a flash drive, the previous firmware version must be 1.35 or later.
Ba tte ry and Po w er Battery Charging 2The icon in the upper-right corner of the
To charge the battery, simply connect the GLX to the AC power adapter. The GLX will automatically power on. If its battery is less than fully charged, the GLX will begin to charge the battery and remain powered on until the battery is fully charged.2 display indicates the condition of the battery. See page 11 for details.
3The GLX is considered idle when
• the GLX is not collecting data,
If the battery is fully charged and AC power is connected, the GLX will automatically save data and shut down after 60 minutes of idle time.3 It will periodically power on and top off the battery as needed. The typical full charging time for a new battery at room temperature is about 14 hours. When practical, allow the GLX to charge its battery in a room-temperature or cooler environment. Place the GLX on a flat surface with its stand unfolded to accommodate air flow and heat dissipation.
• the Stopwatch is not running, • the GLX is not connected to a computer running DataStudio, and • the GLX is not receiving input through its keypad, a mouse, or a USB keyboard. See “Timed Auto Power Off” on page 8 for more information.
Page 100
94
B a t t e r y a n d
P o w e r
While charging, the GLX monitors its own temperature to prevent overheating. The maximum recommended ambient temperature for charging is 32 °C (90 °F) without sensors, or 28 °C (82 °F) with four maximum-load sensors4 connected. If the GLX becomes too hot, it will temporarily stop charging to allow itself to cool, resulting in a longer charge time.
Battery Power and Data File Storage
4A maximum-load sensor is one that draws 100 mA of current from the GLX, such as the PASPORT CO2 sensor. Most PASPORT sensors draw much less current.
The GLX’s RAM (random-access memory) requires a small amount of power. In order to preserve stored data, the GLX automatically shuts down when its battery begins to run low. At that point, AC power must be connected within three days to preserve data files stored in the RAM folder. When powered off, disconnected from AC power, and starting with a fully charged battery, the GLX will store RAM data for two weeks. Flash memory does not require power. Data files stored in the Flash folder will be preserved indefinitely even if the battery runs down or is removed. For permanent storage, save files in the GLX’s Flash folder or transfer files to a USB Flash drive or a computer.5
GLX Storage To maximize the long-term performance of the battery, keep it charged as much as possible. Note that the battery will drain slowly even when the GLX is powered off and disconnected from AC power. When you are not using the GLX, follow these storage guidelines: •
Whenever possible: Keep the GLX connected to AC power.
•
Unplugged for more than a few days: Backup your data and allow the battery to fully charge before disconnecting the AC power.
•
Unplugged for more than a month: Backup your data, allow the battery to fully charge, then follow the instructions under “Manual Internal Disconnection” below. A disconnected battery or a GLX in “deep sleep” mode can be stored for up to a year before you should recharge it.
Battery Disconnection Automatic Internal Disconnection When it is unplugged and turned off, the GLX uses a small amount of battery power to preserve data saved in RAM. In order to avoid fully discharging the battery (which is not good for it), the GLX will go into “deep sleep” mode when either of these conditions is met: •
The GLX has been unused and unplugged for two weeks.
•
The battery has drained to a critical level.
When the GLX enters deep sleep mode, it disconnects its battery by opening a switch on its circuit board. At this point, data saved in RAM is lost, but data saved in Flash is preserved. Connect the GLX to AC power or press the reset button (on the back of the GLX) to turn it back on.
5
See “Data Files Screen” on page 78 for more information.
Page 101
X p l o r e r
G L X
U s e r s ’
G u i d e
95
Manual Internal Disconnection If you anticipate that your GLX will be left unused and unplugged for more than a month, manually put it into deep sleep mode. This will make it more likely that the battery will be charged the next time you use it. Follow these steps: 1.
Leave the GLX plugged in until the battery is fully charged.
2.
Unplug the AC Adapter.
3.
Open the Settings screen (see page 85). F3 to open the Battery Set menu. Press
F3
4.
Press Battery.
5.
You will see a warning message (right). If you are sure that you want to disconnect the battery, press F1 for OK.
6.
The GLX disconnects its battery and powers off. To turn the GLX back on, connect the AC adapter or press the reset button on the back (using a paper clip).
Select Disconnect Battery from the Set menu.
to select Disconnect
F1
Warning Message
Battery Disconnection for Early Hardware Versions Some earlier versions of the GLX do not contain a switch for internal battery disconnection.6 If you have one of these models and you follow the manual disconnect instructions above, the GLX will display a message indicating that it does not support internal battery disconnection. If this is the case, store the GLX connected to AC power or remove the battery door on the back of the GLX and unplug the battery. (Do not connect the AC adapter when the battery in not installed.)
Battery Capacity The operating time for a single battery charge depends on many factors including the age and history of the battery, the number and type of sensors connected, the use of sound output, and the backlight. At an ambient temperature of 25 °C, a GLX with a newer battery, no PASPORT sensors connected (using only the included temperature and voltage probes), sound output turned off and backlight off will operate for about six to seven hours before it automatically saves data and shuts down. You can maximize the operating time by unplugging sensors when they are not collecting data, using the backlight only when necessary, and turning off the GLX while not in use. If the GLX will be collecting data over a long time, set the sampling period of all sensors to 30 s or greater (see page 56). This will allow the GLX to conserve power by “sleeping” between samples. In this mode of data collection, the battery will last for several days or more.
Battery Reconditioning and Replacement As with all rechargeable batteries, the GLX’s nickel metal hydride battery will lose capacity with age and repeated use. Under typical conditions, the battery can be used for about 500 charge-discharge cycles before capacity loss becomes significant.
F2
6
A GLX that does not contain an internal battery switch can be identified by the first four digits of its serial number, which will be less than 0626. These units were manufactured in 2005 and early 2006. You will find the serial number on the barcode sticker on the back of the GLX.
Page 102
96
R e s e t t i n g
When the battery’s capacity begins to decrease, it will continue to function, but it will require more frequent recharging, and the maximum unpowered time for the GLX to store data in RAM will decrease. If this happens, try to recondition the battery by running it through three complete, uninterrupted charge-discharge cycles: Disconnect the AC adapter. Plug in a sensor. Start data collection and wait until the GLX shuts down due to low battery. Plug in the AC adapter and let the GLX charge uninterrupted until the battery gauge indicates full (about 14 hours). Repeat this cycle at least two more times. If the battery can not be reconditioned, replace it with a new battery7 (PASCO part PS-2527): Use a Phillips screwdriver to remove the screws securing the battery door on the back of the GLX. Remove the door, unplug the old battery, and install the new battery in its place. Replace the door. To calibrate the GLX’s battery gauge for the new battery, run it through one full charge-discharge cycle: Connect the AC adapter and allow the battery to fully charge. Then disconnect the AC adapter, plug in a sensor, start data collection, and allow the battery to discharge until the GLX automatically shuts down.
7To avoid damage to the GLX, remove the AC adapter before disconnecting the battery. To preserve data files in the GLX’s RAM folder, transfer them to the Flash folder, a USB storage device, another GLX, or a computer. See “Data Files Screen” on page 78 and “Using the Xplorer GLX with a Computer” on page 99 for instructions.
Re sett ing To Start a New Experiment To start a new experiment without turning off the GLX, go to the Data Files screen (see page 78), press F4 to open the Files menu, and press 1 to select New File. Previous data, displays, and sensor settings will be unloaded from the GLX and returned to their default configurations. pqrs
To Force the GLX to Restart The following procedures are not necessary in normal GLX operation. They will force the GLX to restart and may also result in the loss of data saved in RAM. •
Press and hold
•
Press the key sequence Esc ,
•
Use a paperclip to press the recessed Reset button on the back of the GLX (see picture). The GLX will power off or restart depending on the state of its battery and the presence of AC power.
F4 Start a new experiment for 5 seconds. The GLX will power off. ,
0
. The GLX will restart.
Reset Button
To Restore the GLX to Factory Configuration These procedures are not recommended during normal GLX operation. All data files and system settings will be deleted. The normal method for deleting files stored in RAM or Flash is described on page 80.
Follow these steps to reset system settings to factory defaults and delete saved data in RAM. 1.
Turn the GLX off then on again.
2.
When the Splash Screen is visible, press the key sequence Esc - Õ . Splash screen
Page 103
X p l o r e r
3.
Connect the GLX to a computer running DataStudio to re-install sensor data sheets.
Follow these steps to reset system settings to factory defaults and delete saved data in RAM and Flash. 1.
Turn the GLX off then on again.
2.
When the Splash Screen is visible, press the key sequence Esc -
3.
Connect the GLX to a computer running DataStudio to re-install sensor data sheets.
.
Oper ati ng Te mper atu re The GLX can be operated and stored without damage at temperatures between -10 °C and 40 °C. Do not leave the GLX in a parked car or other environment that may exceed this range. Protect the GLX from long-term exposure to direct sunlight, which may heat the unit above the specified limit even if the surrounding air temperature is less than 40 °C. Temperatures at the extremes of this operating range may affect battery performance, measurement accuracy, and display contrast. Whenever possible, use and store the GLX at or close to normal room temperature.
G L X
U s e r s ’
G u i d e
97
Page 104
98 Operating Temperature