The text of a manual · part 7 of 17

User's Manual PHL-7100 PHL-7200 Ruggedized Portable Data Terminal, pages 61 to 70

Pages 61 to 70 of 168

The original document is the PDF (4.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Opticon PHL-7254

Page 61

OPTICON User's manual PHL-7000 series

6. Bad scanning position. 1) Make sure that the laser beam sweeps across whole bar code. 2) Scanning operations may fail if the illumination beam is positioned as below.

7. Upon reading a bar code, the red LED indicator turns on until the trigger is release or after five seconds. The green LED and the beep tone indicates a good read.

2.5.9 Help Tap “?” to get information for each program.

2-42

Page 62

OPTICON User's manual PHL-7000 series

2.6 Power management 2.6.1 Suspend Mode The PDT will go into a suspend mode when it is idle for a period of time. The idle duration can be customized using the Power control panel (refer to Figure “Schemes Tab”) Suspend mode works and looks just like you have turned the unit off. Press the key to suspend the PDT, Press the key again for the PDT to resume its Previous state. Use the Battery power control panel to set the duration to switch state to Suspend mode when system using battery power. This will save battery power when PDT is not in use. Figure 2-24 Schemes Tab

Suspending: The following conditions will suspend:

z

Press <Power> key while the unit is on. The duration timer of item “Switch state to Suspend” expires, which indicates that there has been no user activity for a specified of time. The battery pack is almost empty.

z

Tap Start > Suspend z z

Tap here to let PDT enter into suspend mode Figure 2-25 Suspend

2-43

Page 63

OPTICON User's manual PHL-7000 series

2.6.2 Resuming Use the following method to resume (wake up the PDT): Press <Power> key to suspend or resume (wake up). When a battery pack completely discharges while the unit is in suspend mode, the PDT remains suspended until discharged battery condition is corrected. z

2.7 Resetting the PDT 2.7.1 Warm Reset A warm reset is a transition from the on, idle, or suspend power state that close all applications, clears the working RAM, but preserves the file system. Reason to Warm Reset: If an application “hangs”, initiate a warm reset to terminate the application only. Process to Warm Reset: To warm reset, press “F1” and “F4” button simultaneously. After Warm Reset: z The desktop appears with the application shortcuts on the screen. z The custom settings in the registry are persistent.

2.7.2 Cold Reset CAUTION: Try warm reset before you initiate Cold Reset. All applications will be Closed and working RAM and all files will be cleared if you initiate the Cold Reset. It is strongly recommended to back up your files to FlashROM, Flashcard or PC. 1) You can use Cold Reset to initialize the PDT if WINCE.NET OS lock up or Warm Reset has no effect. 2) To perform Cold Reset, press “Power”, “F1” and “F4” button simultaneously. 3) PDT will initiate boot up after Cold Reset.

2-44

Page 64

OPTICON User's manual PHL-7000 series

Chapter 3. PDT settings 3.1 Introduction To view available options for PDT’s setting, tap Start > Settings. Then, there are three items inside Settings: “Control Panel”, “Network and Dial-up” and “Taskbar and Start”.

3.2 Control Panel To view the Control Panel and settings you can modify by tapping Start > Settings > Control Panel.

Figure 3-1 Control Panel

3-1

Page 65

OPTICON User's manual PHL-7000 series

3.2.1 BarCode Settings ICON

ITEM & FUNCTION •

9 9 9 9 9

Start bar code settings tool : Enable or disable bar code scanner Select bar code symbologies Select prefixes and suffixes Select quiet zone options Select read mode options

Table 3-1 Bar code settings

3.2.1.1 Basic TAB In the “Basic tab” the bar code reader behavior can be changed.

Figure 3-2 Basic Tab

Field name

Description

Enable bar code reader

Enable or disable the bar code reader. Default is enabled.

Beep After Scan OK

Select the number of beeps after scanning a bar code which is successfully decoded by the bar code reader.

3-2

Page 66

OPTICON User's manual PHL-7000 series

Keybd Message

Read mode

Read time

None

Disable beep after scanning bar code.

One Time

Beep one time after scanning bar code (default).

Two Times

Beep two times after scanning bar code.

Select the bar code data transfer method Disable

Data from bar code reader is ignored.

Type Writing

Data from bar code reader is send as keyboard data to the application which currently has the focus (default).

Select the bar code reading mode. Single read

When a bar code has been decoded, the reader will be turned OFF. The reader must be triggered again to read another bar code (default).

Multiple read

When a bar code has been decoded, the reader will stay ON for the time as set by ‘Read time’ options. The same bar code can only be decoded again after the label has not been detected for a number of scans.

The length of the period that the reader is ON after the trigger switch is pressed, or (in multiple read mode), after a label has been read. 0 sec

Reader will stay on as long as the trigger switch is being pressed.

1 sec

1 second

2 sec

2 seconds (default)

3 sec

3 seconds

4 sec

4 seconds

5 sec

5 seconds

6 sec

6 seconds

7 sec

7 seconds

8 sec

8 seconds

3-3

Page 67

OPTICON User's manual PHL-7000 series

Version

9 sec

9 seconds

Indefinitely

Single read mode : reader will stay on until a bar code is read. Multiple read mode : reader will stay on until power is recycled (not recommended)

X1

No multiplication of read time (default)

X10

Read time * 10

Information field which shows the bar code readers firmware version. RBAV01xx is used for 1D laser module. FL23Jxx is used for 2D CMOS module. If no version is displayed the bar code reader is not found. Note xx can have a value between 01 and 99.

Table 3-2 Basic TAB description

3.2.1.2 Code Configure TAB In the Code Configure tab the bar code symbologies can be enabled or disabled. It is strongly recommended to select only the required code. Advantages of selecting the required codes are : • • • faster reading, no accidental scanning of unwanted bar codes, reduced probability of reading errors which can not be prevented completely, because of the limited security of some bar code types.

Bar code specific options can not be selected in this version of the Bar Code Settings tool. In case bar code specific options are required, refer to Opticon’s Universal Menu Book, chapter 3 and lookup the serial command sequence, and enter this commands sequence in Bar Code Settings tool’s “Advanced” TAB.

3-4

Page 68

OPTICON User's manual PHL-7000 series

The Opticon Universal Menu Book can be downloaded from the opticon website. Note : support for symbologies may be dependent of the bar code reader firmware.

Figure 3-3 Code configure Tab

Field name

Description

UPC

Enable UPC A and UPC-E (default)

UPC+2

Enable UPC-A ADDON 2 and UPC-E ADDON 2

UPC+5

Enable UPC-A ADDON 5 and UPC-E ADDON 5

EAN

Enable EAN-13 and EAN-8 (default)

EAN+2

Enable EAN-13 ADDON 2 and EAN-8 ADDON 2

EAN+5

Enable EAN-13 ADDON 5 and EAN-8 ADDON 5

Code 39

Enable Code 39 (default)

Tri-optic

Enable Tri-optic (default)

Codabar

Enable Codabar (default)

Industrial 2of5

Enable Industrial 2of5 (default)

Interleaved 2of5

Enable Interleaved 2of5 (default)

S Code

Enable S Code (default)

Matrix 2of5

Enable Matrix 2of5

3-5

Page 69

OPTICON User's manual PHL-7000 series

Chinese Post Matrix 2of5

Enable Chinese Post Matrix 2of5

Korean Postal Authority code

Enable Korean Postal Authority code

IATA

Enable IATA (default)

MSI/Plessey

Enable MSI/Plessey (default)

Telepen

Enable Telepen (default)

UK/Plessey

Enable UK/Plessey (default)

Code 128

Enable Code 128 (default)

Code 93

Enable Code 93 (default)

Code 11

Enable Code 11

RSS-14

Enable RSS-14

RSS-limited

Enable RSS-limited

RSS-expanded

Enable RSS-expanded

PDF417

Enable PDF417 (default)

MicroPDF417

Enable MicroPDF417 (default)

Table 3-3 Code configure description 1D laser

Field name

Description

UPC

Enable UPC A and UPC-E (default)

UPC+2

Enable UPC-A ADDON 2 and UPC-E ADDON 2

UPC+5

Enable UPC-A ADDON 5 and UPC-E ADDON 5

EAN

Enable EAN-13 and EAN-8 (default)

EAN+2

Enable EAN-13 ADDON 2 and EAN-8 ADDON 2

EAN+5

Enable EAN-13 ADDON 5 and EAN-8 ADDON 5

Code 39

Enable Code 39 (default)

Tri-optic

Enable Tri-optic (default)

Codabar

Enable Codabar (default)

Industrial 2of5

Enable Industrial 2of5 (default)

Interleaved 2of5

Enable Interleaved 2of5 (default)

IATA

Enable IATA (default)

MSI/Plessey

Enable MSI/Plessey (default)

Code 128

Enable Code 128 (default)

Code 93

Enable Code 93 (default) 3-6

Page 70

OPTICON User's manual PHL-7000 series

RSS-14

Enable RSS-14

RSS-limited

Enable RSS-limited

RSS-expanded

Enable RSS-expanded

DataMatrix ECC000-ECC140

Enable DataMatrix ECC000-ECC140

DataMatrix ECC200

Enable DataMatrix ECC200 (default)

Aztec

Enable Aztec (default)

Aztec Runes

Enable Aztec Runes

QR Code

Enable QR Code (default)

Maxi Code

Enable Maxi Code (default)

PDF417

Enable PDF417 (default)

MicroPDF417

Enable MicroPDF417 (default)

Table 3-4 Code configure description 2D CMOS

3.2.1.3 Prefix and suffix TAB With these options alterations can be made to the format of the transmitted data string.

Options available are : - Transmission of a preamble, - Transmission of a prefix, - Transmission of a suffix, - Transmission of a postamble.

Figure 3-4 Prefix and Suffix Tab

3-7