Page 111
OPTICON User's manual PHL-7000 series
Figure 3-79 Stylus Properties
Figure 3-80 Stylus Properties
Figure 3-81 Stylus Properties
Figure 3-82 Stylus Properties
3-48
Page 112
OPTICON User's manual PHL-7000 series
3.2.20 System ICON
ITEM & FUNCTION • 9
•
“General” Tab (Figure 3-83) : To show: ¾ Firmware information ¾ Information about Processor type, Memory size, Expansion card “Memory” (Figure 3-84) :
9
Move the slider to adjust memory allocation. Default storage memory is normally set to about 8MB with the reminder assigned to Program memory.
9
Press the “OK” key on the Keypad.
Note: the difference is occupied by OS between the RAM size in Information properties and total memory size of storage memory and program memory • 9
9 9
• 9
“Device Name” Tab (Figure 3-85) : Your device uses this information to identify itself to other computers. The input panel will open to facilitate data entry. To close the Device Name, press the “OK” button, or press the <Enter> key on keypad. “Copyrights” Tab (Figure 3-86) : Refer to this tab for specific copyright data. As a user, you are responsible to read this statement.
Table 3-28 System
3-49
Page 113
OPTICON User's manual PHL-7000 series
Figure 3-83 System Properties
Figure 3-84 System Properties
Figure 3-85 System Properties
Figure 3-86 System Properties
3-50
Page 114
OPTICON User's manual PHL-7000 series
3.2.21 Volume & Sounds Properties ICON
ITEM & FUNCTION • 9
“Volume” Tab (Figure 3-87) : The factory default for Volume is the forth level. You can adjust the volume to your environment and comfort. ¾
• 9
Set the volume by adjusting the slider from Soft to Loud, or press Right or Left edge of Navigation keys
“Sounds” Tab (Figure 3-88) : Enable the desired sounds for key clicks, screen taps, notifications, and applications.
Table 3-29 Volume & Sound
Figure 3-87 Volume & Sound
Figure 3-88 Volume & Sound
3-51
Page 115
OPTICON User's manual PHL-7000 series
3.3 Taskbar and Start Menu ICON Taskbar and Start Menu
ITEM & FUNCTION • 9
“General” Tab : In this tab, You can change the position of the Taskbar and Start menu ¾ ¾ ¾
•
Is always on top or not Auto hide or not Show Clock or not
“Advanced” Tab :
9
Tap the “Clear” button to remove the contents of the Documents Menu.
9
Enable “Expand Control Panel” to list all icons of Control Panel from top to bottom.
Table 3-30 Taskbar and Start menu
3-52
Page 116
OPTICON User's manual PHL-7000 series
Chapter 4. Communication 4.1 Installing & Setting Up Microsoft ActiveSync 4.1.1 Installing Microsoft ActiveSync on the Host PC Microsoft ActiveSync is a file transfer tool to synchronize the files on a PC with the files on your PDT. To install Microsoft ActiveSync, complete the following steps on the PC: 1. Go to the Microsoft website www.microsoft.com. In the search field, search for "active sync". Download the latest current version of ActiveSync. 2. Install the latest version of Microsoft ActiveSync on the host PC. 3. Open ActiveSync. 4. Select File > Communication Settings from ActiveSync’s menu bar. 5. Go to “Using ActiveSync” on page 4-1 to continue using ActiveSync. 4.1.2 Connecting PDT to Host PC 1. You can use either the USB/Serial (RS232) port from the IRU-7000 cradle or a USB/Serial (RS232) cable to connect the PDT to the Host PC. • To use the cradle, you must first insert the PDT into the slot, making sure that the unit is firmly seated the cradle. • To use the cable, connect the USB/Serial cable to the PDT. 2. Connect the USB/Serial cradle or cable to the Host PC’s serial port or USB port. 3. Connect the cradle or PDT to the power adapter and power source.
4.2 Using ActiveSync Use ActiveSync to transfer and synchronize files between the PDT and the Host PC. 4.2.1 Setting up a Partnership During the Microsoft ActiveSync installation, you were prompted to create a partnership with your mobile device. When you set up a partnership, you select synchronization and file conversation settings, which are contained in a file on your desktop computer. This file enables your desktop computer to recognize your device. Only devices that have a partnership with a desktop computer can synchronize information between the two computers. For more information on partnerships, please refer to your Microsoft ActiveSync documentation or help file.
4-1
Page 117
OPTICON User's manual PHL-7000 series
Transferring Files: To transfer files, complete the following steps on the host PC: 9 9 9
9
Select Start > Programs > Communication > (Serial, or USB) Activesync. Double-click on the selected ActiveSync icon After you have established a connection with PDT, tap the “Explore” button at the top of the ActiveSync window (or select Explore from the File menu). Navigate to the target directory on your PDT and copy the desired file by using the Copy/paste method or dragging and dropping the desired file(s) into the folder.
Figure 4-1 Communication
4-2
Page 118
OPTICON User's manual PHL-7000 series
4.2.2 ActiveSync File Synchronization ActiveSync files synchronization requires an ActiveSync partnership between the PDT and the Host PC. Refer to “Setting up a Partnership”, above: 9 Select the files in the synchronization configuration for the PDT partnership. 9
Select Tools > Options from the ActiveSync command bar to configure the synchronization options.
9
Place the file to be synchronized in the Synchronization folder createdin your My Documents directory. Defaults to the desktop. During the ActiveSync connection, all files in the Synchronization folder will be synchronized to the \My Documents directory on the PDT.
Figure 4-2 Connected
4.3 Networking Please see the 3.2.12 “Owner”, Table 3-20 “Owner” on page 3-40 for setting up the network ID. And see the 2.5.6 Setting Up Wireless LAN RF to setup the 802.11b Wireless LAN for RF connecting.
4-3
Page 119
OPTICON User's manual PHL-7000 series
Chapter 5. Software Applications 5.1 Introduction The PDT includes several applications for example Calculator, email, etc. You can switch to any software application by tapping the Start Menu.
5.2 Software Applications 5.2.1 Calculator It can be used for basic calculations with “+”, “-“ “*” and “/“. 9
Procedure: Tap numeric number ¾
¾
Tap one operator “+”, “-“, “*” or “/” Then, tap another numeric number Tap another operator or numeric number if needed
¾
Tap “=” to get result
¾ ¾
9
Button Function: ¾ “MC” – Memory Clear : clear the memory ¾ “MS” – Memory Store : store the displayed value to memory ¾ “MR” – Memory Recall : Display the most recent stored value ¾ “M+” – Add stored numeric number into the displayed numeric value. ¾ “Backspace” – Same as “ backspace” key ¾ “CE” – Clear current keying numeric number. Same as “ Delete” key ¾ “C” – Clear the current calculation. Same as “ESC” key.
5-1
Page 120
OPTICON User's manual PHL-7000 series
5.2.2 Inbox Use Inbox to send and receive e-mail messages in the following ways: 9 Synchronize e-mail messages with Microsoft Exchange or Outlook on the Host Computer. 9 Send and receive e-mail messages by connecting directly to an e-mail server through an Internet server provider (ISP) or a network. 5.2.2.1 Setup “Inbox”: 9
Select Start > Programs > Inbox to open it.
9
Select Service > Options from the command bar. Drag the dialog to show the right edge to configure e-mail.
9
Select “Add…”
9
In the “Service Type” list, select POP3 Mail or IMAP4 Mail. (POP3 is the most common mail protocol for ISPs).Enter a unique name for e-mail service in the “Service name” field. This name cannot be changed later.
9
Select “OK”.
9
The Mail Service Setup wizard appears after you add a service. If you are adjusting the setting of an existing service, select Service > Options, select the service you are using, and then Properties. In the Service Definition dialog box, complete the following entries as needed: ¾
Connection: Select the name of the connection you created to connect to the mail server. If you are receiving e-mail through a network(Ethernet) connection, select Network Connection. If you want Inbox to use your current connection, select (none). If you have not created a connection, select Create new connection. Double-tap the “Make new Connection” icon, and follow the instructions in wizard. When finished, select Inbox in the Taskbar and continue setting up Inbox.
¾
POP3 Host(POP3 only): Enter the name of the mail server you use to receive and send messages.
¾
Server(IMAP4 only): Enter the name of the mail server you use to receive and send messages.
¾
User ID: Enter the user name or mailbox ID assigned to you.
¾
Password: Enter the password you use to access this mail account. If you do not want to be prompted to enter the password each time you connect, select “Save password”.
¾
Domain(Windows NT): Enter your Windows NT domain name. This name is required only when connecting to networks, such as a corporate network, that use
5-2