The text of a manual · part 2 of 3
OPN 2001 Specifications Manual, pages 9 to 16
Pages 9 to 16 of 24
The original document is the PDF (543 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Opticon OPN-2001
Page 9
Opticon OPN 2001 Specifications Manual
•
The number of scans when fully charged is determined based on a scanning operation where the laser beam is on for 4 seconds and the lighting LED is on for 1 second per scan.
6.4. Main Battery The main battery is a lithium-ion rechargeable battery. Nominal capacity: 150 mAh Nominal voltage: 3.7 V DC
6.5. Battery Operating Time and Charging Time Parameter
Specification
Notes Conditions: Every scan, 2 seconds laser beam on and 1 second good read LED on
Main battery pack operating time
1000 scans
Current consumption
100 mAh operation, idle
Power management
Extreme low power
Charging time
2 ½ hours
Charging method
Recharging lithium-ion pack in scanner via USB port
Note: Battery life may be shorter than specified above when the quality of the battery pack is degraded.
7. Optical Specifications 7.1. Laser Scan Specifications Parameter
Specification
Unit
Light-emitting element
Red laser diode, Emission wavelength
650 ±10 (25° C)
nm
Light output
1.0 or less mW
Scanning method
Bi-directional scanning, Scanning speed
100 ±20 scans/s
Scan angle
Scan angle: 54 ±5
°
Read angle: 44 (Min)
°
Notes: Refer to chapter 8, “Technical Specifications,” to read about scanning performance.
9
Page 10
Opticon OPN 2001 Specifications Manual
7.2. Laser Scanning Standards 7.2.1. Laser Scanning Tilt Laser scanning tilt is the vertical difference between both ends of a laser scan line. Measure it in the middle of the laser scan line. • Up to 0.92 degrees angle in a vertical direction from the scan origin (mirror motor). •
Up to 2.46 mm at 150 mm from the scan origin.
7.2.2. Scanning Curvature The maximum difference between the laser scan line and the line between both ends of the laser scan line. Measure it in the middle of the laser scan line. • Up to 1.17 degrees angle in a vertical direction from the scan origin (mirror motor). •
Up to 3.06 mm at 150 mm from the scan origin.
Figure 1: Scanning curvature
10
Page 11
Opticon OPN 2001 Specifications Manual
8. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient temperature and humidity:
Room temperature (5 to 35º C) Room humidity (45% to 85% RH)
Ambient light:
500 to 900 lx
Background:
Barcode = black Space = white Margin = white Background of label = black
Power supply voltage:
3.7 V
Decoding test:
Approve the performance when decoding is successful in all ten tests. (Decoding is deemed successful when completed in 0.5 seconds or less.)
8.1. Print Contrast Signal (PCS) 0.45 or higher (over 70% of reflectivity of space and quiet zone). PCS=
Reflectance of white bar-Reflectance of black bar Reflectance of white bar
Scanning performance may decline if dirt or scratches mar the optical window. Keep the optical window clean.
8.2. Minimum Resolution 0.127 mm
11
Page 12
Opticon OPN 2001 Specifications Manual
8.3. Scan Area and Resolution 8.3.1. Depth of Field The depth of field is measured from the edge of the data collector. The scan area is a circular area centered on the beam, which appears at various resolutions.
Figure 2: Depth of field and resolution
Symbology
Resolution (mm)
Decode Depth (mm)
PCS
Code 39
1.0 mm
60–570
0.9
Code 39
0.5 mm
40–360
0.9
Code 39
0.25 mm
40–220
0.9
Code 39
0.15 mm
40–120
0.9
Code 39
0.127 mm
50–100
0.9
Conditions Barcode Sample: OPTOELECTRONICS Test Sample N/W Ratio:
1:2.5
Angle:
α = 0°, β = 15°, γ = 0°
Curvature:
R=∞
12
Page 13
Opticon OPN 2001 Specifications Manual
Resolution
Symbology
PCS
Quiet Zone
Digit
1.0 mm
Code 39
0.9
25 mm
1
0.5 mm
Code 39
0.9
18 mm
3
0.25 mm
Code 39
0.9
10 mm
8
0.15 mm
Code 39
0.9
7 mm
10
0.127 mm
Code 39
0.9
5 mm
4
8.4. Pitch, Skew, and Tilt 8.4.1. Pitch Angle α = ±30°
Figure 3: Pitch
13
Page 14
Opticon OPN 2001 Specifications Manual
8.4.2. Skew Angle and Dead Zone Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8° (There are some areas in which decoding fails due to specular reflection)
Figure 4: Skew and dead zone
8.4.3. Tilt Angle γ = ±20°
Figure 5: Tilt angle
14
Page 15
Opticon OPN 2001 Specifications Manual
Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance
100 mm from the edge of the data collector
Label
Pitch, Skew Angle, Dead Zone PCS = 0.9, Resolution = 0.25mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Tilt Angle PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Pitch
Skew angle: β = +15°, tilt angle: γ = 0°
Skew
Pitch angle: α = 0°, tilt angle: γ = 0°
Tilt
Pitch angle: α = 0°, skew angle: β = +15°
Curvature
R=∞
8.5. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥20 mm.
Figure 6: Curvature
Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm Distance:
100 mm from the edge of the data collector
Angle:
Skew Angle β = +15°
15
Page 16
Opticon OPN 2001 Specifications Manual
9. Interface Specifications 9.1. USB Interface Specifications 9.1.1. Settings The interface is full-speed USB. 9.1.2. Interface Circuit
Figure 7: Interface circuit
10. Cable and Connector 10.1. USB Cable A dedicated cable with PC connector is provided.
10.2. Connector
Figure 8: Mini USB B connector
16
Contact Number
Signal Name
1
VCC
2
-DATA
3
+DATA
4
NC
5
GND