For the Opticon OPN-2001

Page 9

Opticon OPN 2001 Specifications Manual

•

The number of scans when fully charged is determined based on a scanning operation where the laser beam is on for 4 seconds and the lighting LED is on for 1 second per scan.

6.4. Main Battery The main battery is a lithium-ion rechargeable battery. Nominal capacity: 150 mAh Nominal voltage: 3.7 V DC

6.5. Battery Operating Time and Charging Time Parameter

Specification

Notes Conditions: Every scan, 2 seconds laser beam on and 1 second good read LED on

Main battery pack operating time

1000 scans

Current consumption

100 mAh operation, idle

Power management

Extreme low power

Charging time

2 ½ hours

Charging method

Recharging lithium-ion pack in scanner via USB port

Note: Battery life may be shorter than specified above when the quality of the battery pack is degraded.

7. Optical Specifications 7.1. Laser Scan Specifications Parameter

Specification

Unit

Light-emitting element

Red laser diode, Emission wavelength

650 ±10 (25° C)

nm

Light output

1.0 or less mW

Scanning method

Bi-directional scanning, Scanning speed

100 ±20 scans/s

Scan angle

Scan angle: 54 ±5

°

Read angle: 44 (Min)

°

Notes: Refer to chapter 8, “Technical Specifications,” to read about scanning performance.

9

Page 10

Opticon OPN 2001 Specifications Manual

7.2. Laser Scanning Standards 7.2.1. Laser Scanning Tilt Laser scanning tilt is the vertical difference between both ends of a laser scan line. Measure it in the middle of the laser scan line. • Up to 0.92 degrees angle in a vertical direction from the scan origin (mirror motor). •

Up to 2.46 mm at 150 mm from the scan origin.

7.2.2. Scanning Curvature The maximum difference between the laser scan line and the line between both ends of the laser scan line. Measure it in the middle of the laser scan line. • Up to 1.17 degrees angle in a vertical direction from the scan origin (mirror motor). •

Up to 3.06 mm at 150 mm from the scan origin.

Figure 1: Scanning curvature

10

Page 11

Opticon OPN 2001 Specifications Manual

8. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient temperature and humidity:

Room temperature (5 to 35º C) Room humidity (45% to 85% RH)

Ambient light:

500 to 900 lx

Background:

Barcode = black Space = white Margin = white Background of label = black

Power supply voltage:

3.7 V

Decoding test:

Approve the performance when decoding is successful in all ten tests. (Decoding is deemed successful when completed in 0.5 seconds or less.)

8.1. Print Contrast Signal (PCS) 0.45 or higher (over 70% of reflectivity of space and quiet zone). PCS=

Reflectance of white bar-Reflectance of black bar Reflectance of white bar

Scanning performance may decline if dirt or scratches mar the optical window. Keep the optical window clean.

8.2. Minimum Resolution 0.127 mm

11

Page 12

Opticon OPN 2001 Specifications Manual

8.3. Scan Area and Resolution 8.3.1. Depth of Field The depth of field is measured from the edge of the data collector. The scan area is a circular area centered on the beam, which appears at various resolutions.

Figure 2: Depth of field and resolution

Symbology

Resolution (mm)

Decode Depth (mm)

PCS

Code 39

1.0 mm

60–570

0.9

Code 39

0.5 mm

40–360

0.9

Code 39

0.25 mm

40–220

0.9

Code 39

0.15 mm

40–120

0.9

Code 39

0.127 mm

50–100

0.9

Conditions Barcode Sample: OPTOELECTRONICS Test Sample N/W Ratio:

1:2.5

Angle:

α = 0°, β = 15°, γ = 0°

Curvature:

R=∞

12

Page 13

Opticon OPN 2001 Specifications Manual

Resolution

Symbology

PCS

Quiet Zone

Digit

1.0 mm

Code 39

0.9

25 mm

1

0.5 mm

Code 39

0.9

18 mm

3

0.25 mm

Code 39

0.9

10 mm

8

0.15 mm

Code 39

0.9

7 mm

10

0.127 mm

Code 39

0.9

5 mm

4

8.4. Pitch, Skew, and Tilt 8.4.1. Pitch Angle α = ±30°

Figure 3: Pitch

13

Page 14

Opticon OPN 2001 Specifications Manual

8.4.2. Skew Angle and Dead Zone Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8° (There are some areas in which decoding fails due to specular reflection)

Figure 4: Skew and dead zone

8.4.3. Tilt Angle γ = ±20°

Figure 5: Tilt angle

14

Page 15

Opticon OPN 2001 Specifications Manual

Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance

100 mm from the edge of the data collector

Label

Pitch, Skew Angle, Dead Zone PCS = 0.9, Resolution = 0.25mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Tilt Angle PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm

Pitch

Skew angle: β = +15°, tilt angle: γ = 0°

Skew

Pitch angle: α = 0°, tilt angle: γ = 0°

Tilt

Pitch angle: α = 0°, skew angle: β = +15°

Curvature

R=∞

8.5. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥20 mm.

Figure 6: Curvature

Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm Distance:

100 mm from the edge of the data collector

Angle:

Skew Angle β = +15°

15

Page 16

Opticon OPN 2001 Specifications Manual

9. Interface Specifications 9.1. USB Interface Specifications 9.1.1. Settings The interface is full-speed USB. 9.1.2. Interface Circuit

Figure 7: Interface circuit

10. Cable and Connector 10.1. USB Cable A dedicated cable with PC connector is provided.

10.2. Connector

Figure 8: Mini USB B connector

16

Contact Number

Signal Name

1

VCC

2

-DATA

3

+DATA

4

NC

5

GND