Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 8

NFT 2100/2200 Miniature High Speed CCD Fixed Position Barcode Scanners User's Guide, pages 61 to 70

Pages 61 to 70 of 73

The original document is the PDF (332 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Opticon NFT-2100

Page 61

Manual No. 25-ULNFT2100-01; Nov., 2006

NFT2100/2200 CCD Fixed Mount Barcode Scanner

28. Scanner Timeout (Trigger Enabled Mode only) These commands, which are only applicable in the Trigger Enabled mode, establish the time-out period after the trigger pulse is received. In Single Read Mode, the time out is terminated upon a good read. In Multiple Read and Continuous Read Modes the time out period is restarted after any good read.

Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

Y1

1 Second after triggering

Z2

Y2

2 Seconds after triggering

Z3

Y3

3 Seconds after triggering

Z!

Y4

4 Seconds after triggering

Z5

Y5

5 Seconds after triggering

Z6

Y6

6 Seconds after triggering

Z7

Y7

7 Seconds after triggering

Z8

Y8

8 Seconds after triggering

Z9

Y9

9 Seconds after triggering

Z:

YL

Read time x 10

ZM

Y0

On time follows the Hardware trigger active time. Can be terminated by sending the Y command

Z1

YM

Stays ON indefinitely after triggering. Must be terminated by sending the Y commands.

ZN

%

Page 61

Page 62

Manual No. 25-ULNFT2100-01; Nov., 2006

NFT2100/2200 CCD Fixed Mount Barcode Scanner

29. Multiple Read Reset Time This option is used in conjunction with the multiple read mode. The selected time sets the period the scanners should be pointed away from a label before that same label can be decoded again. Indefinitely means that the next bar code must always be different during the time the scanner is triggered.

Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

AH

Set at 50 msec

BI

AI

Set at 100 msec

BJ

AJ

Set at 200 msec

BK

AK

Set at 300 msec

BL

AL

Set at 400 msec

BM

AM

Set at 500 msec

BN

AN

Set at 600 msec

BO

AG

Set indefinitely

BH

%

Page 62

Page 63

Manual No. 25-ULNFT2100-01; Nov., 2006

NFT2100/2200 CCD Fixed Mount Barcode Scanner

30. Quiet Zone Options With this option the scanner can decode bar codes that have smaller quiet zone margins than specified for the symbology. Be careful when using this option as its use may increase the possibility of partial and ghost reads. Do not use smaller margin checks than necessary. If possible, replace the bar codes labels with others that have the correct quite zone margins.

Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

YN

No margin check

ZO

YO

Margin check 1/7 nominal

ZP

YP

Margin check 2/7 nominal

ZQ

YQ

Margin check 3/7 nominal

ZR

YR

Margin check 4/7 nominal

ZS

YS

Margin check 5/7 nominal

ZT

YT

Margin check 6/7 nominal

ZU

YU

Margin check normal

ZV

%

Page 63

Page 64

Manual No. 25-ULNFT2100-01; Nov., 2006

NFT2100/2200 CCD Fixed Mount Barcode Scanner

31. Redundant Decoding The Number of Redundant Decodes determines how many times the scanner must decode a bar code and obtain the same value before it will transmit the data. For example, if the redundancy is set at three times, the scanner will not transmit data until it has completed three consecutive, identical “good reads”. In the case of a poor label which generates an intermediate “no decode” within a sequence of four scans where three of the four have resulted in “good reads”, the scanner will transmit the data after the fourth scan. In other words, a “no decode” does not restart the sequence. Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

X2

Read bar code three times

Y3

X3

Read bar code four times

Y!

%

32. Transmitting Error Indications Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

WD

Disable ACK/NAK response to sent command

XE

WC

Enable OK=ACK, ERROR=NAK, response to sent command

XD

%

Page 64

Page 65

Manual No. 25-ULNFT2100-01; Nov., 2006

NFT2100/2200 CCD Fixed Mount Barcode Scanner

33. No read error messages. The scanner can be programmed to transmit an error message when no barcode is read. The unit must be in trigger mode, then, the error message will be sent at the end of a trigger time out. 2 types of messages can be sent. The first type will indicate that no label was present or that nothing was in front of the scanner. The second type will indicated that a barcode was present but could not be decoded. To program an error message, scan the appropriate command below then scan up to 4 direct input characters. To remove the error message, scan the appropriate command below but do not scan any direct input characters.

33. Programming No read Error Messages Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

TH

Program Error message for No label present.

UI

TI

Program Error message for label present but not decodable.

UJ

34. Good Read LED Operation Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

T4

Good read LED disabled after decode

U5

T5

Good read LED ON after decode for .20 seconds

U6

T6

Good read LED ON after decode for .40 seconds

U7

T7

Good read LED ON after decode for .80 seconds

U8

%

Page 65

Page 66

Manual No. 25-ULNFT2100-01; Nov., 2006

NFT2100/2200 CCD Fixed Mount Barcode Scanner

Appendix D: NFT2100 Dimensional Drawing

(All dimensions in millimeters [inches])

NFT2100

47.0 [1.85]

14.0 [0.55]

2-M3

20.0 [0.79]

2-M3

14.5 [0.57] 27.5 [1.08] 5.5 [0.22]

12.0 [0.47]

5.5 [0.22] 27.5 [1.08]

View Line

55.0 [2.17]

14.0 [0.55] 12.0 [0.47]

8.3 [0.33]

24.65 [0.97]

LED

22.3 [0.88]

Page 66

Page 67

Manual No. 25-ULNFT2100-01; Nov., 2006

NFT2100/2200 CCD Fixed Mount Barcode Scanner

Appendix D: (cont.) NFT2200 Dimensional Drawing (All dimensions in millimeters [inches])

Good Read Light

24.65 [0.97]

22.3 [0.88]

6.0 [0.24]

4-M3 Mounting Holes 8.3 [0.33] 14.0 [0.55]

6.3 [0.25] 24 [0.9]

27.5 [1.08] 5.5 [0.22]

14.0 [0.55]

20.0 [0.79]

12.0 [0.47]

27.5 [1.08] 31.4 [1.24]

5.5 [0.22] 80.0 [3.15]

NFT2200

13°

52.0 [2.05]

55.0 [2.17]

Page 67

Page 68

Manual No. 25-ULNFT2100-01; Nov., 2006

NFT2100/2200 CCD Fixed Mount Barcode Scanner

Appendix E: NFT 2100 – Optical Performance Depth of Field Table (Grade A Labels) NFT2100

NFT2200

Density

Min. Distance (inches)

Max Distance (inches)

Range (inches)

Min. Distance (inches)

Max Distance (inches)

Range (inches)

6 mil

0.9

1.6

0.7

0.7

1.4

0.7

10 mil

0.8

1.7

0.9

0.6

1.5

0.9

20 mil

0.8

2.0

1.2

0.6

1.8

1.2

40 mil

0.9

2.4

1.5

0.7

2.2

1.5

Depth of Field Chart NFT2200 Focal Distance 1.2" (31.4 mm) 6 Mil 10 Mil 20 Mil 40 Mil NFT2200 6 Mil 10 Mil 20 Mil 40 Mil NFT2100

0

0.5

Focal Distance 1.4" (35.4

1.0 1.5 2.0 Distance from front of scanner case (inches)

2.5

3.0

Field of View Table Distance from Front of Case

0.75"

1.0"

Focal Distance 1.2"

Focal Distance 1.4"

1.5"

2.0"

25.4mm

25.4mm

31.4mm

35.4mm

38.1mm

50.8mm

NFT2100 Field of View

2.2"

2.6"

2.9"

3.1"

3.3"

4.0"

55mm

66mm

73mm

80mm

83mm

101mm

NFT2200

2.5"

2.9"

3.1"

3.4"

3.6"

4.3"

Field of View

63mm

73mm

78mm

86mm

91mm

109mm

Page 68

Page 69

Manual No. 25-ULNFT2100-01; Nov., 2006

NFT2100/2200 CCD Fixed Mount Barcode Scanner

Appendix F: Placement Drawing (All dimensions in millimeters [inches]) These drawings shows one possible placement of the scanner relative to the target label. Other orientations are possible depending on barcode density and barcode length. Please use the optical information provided in appendix E as guidance.

35.4 [1.39]

Target Barcode

80.0 [3.15] 0.5 [0.02] Read Line

35.4 [1.39]

14.0 [0.55] 5.5 [0.22] Recommended Skew =

27.5 [1.08]

49.4 [1.95] R ead

13°

14.5±2.0 [0.57±0.08]

Line

Target Barcode

35.4 [1.39]

NFT2100 Placement Drawing

Page 69

Page 70

Manual No. 25-ULNFT2100-01; Nov., 2006

NFT2100/2200 CCD Fixed Mount Barcode Scanner

Appendix F (cont.): Placement Drawing (All dimensions in millimeters [inches])

Target Barcode

27.5 [1.08]

80.0 [3.15] 36.6 [1.44] 31.4 [1.24] Line Re a d

13°

6.3 [0.25]

27.5 [1.08] 90°

14.0 [0.55]

Target Barcode 19.8 [0.78]

5.5 [0.22]

NFT2200 Placement Drawing

Page 70