Set up your personal configuration bar code configuration and commands manual

Universal menu book

Page 2

OPTICON Universal menu book

Set up your personal configuration bar code configuration and commands manual

Universal menu book ver. 12 © December 2009 Ui

Page 3

OPTICON Universal menu book

CAUTION: This information is subject to change without prior notice.

LIMITED WARRANTY AND DISCLAIMERS

Copyright 2006, Opticon Sensors Europe B.V. All rights reserved.

Under all circumstances this manual should be read attentively, before installing and or using the product.

This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon Sensors Europe.

Serial number A serial number appears on all Opticon products. This official registration number is strictly related to the device purchased. Make sure that the serial number appearing on your Opticon device has not been removed. Removing the serial number might affect the warranty conditions and liability disadvantageously, so please be strict at maintaining the label with serial number on the Opticon product. Warranty / Warranty period / Liability Unless otherwise agreed in a contract, all Opticon products are warranted for the period of two years after purchase, covering defects in material and workmanship. Opticon will repair or, at its opinion, replace products that prove to be defective in material or workmanship under proper use during the warranty period. Opticon will not be liable in cases where modifications are made by the customer. In such case the standard repair charge will be applicable. The standard charge for repair will also be applicable in cases where no defect is found at all. These rules also apply for products that are still under warranty. Under no circumstance will Opticon Sensors Europe, be liable for any direct, indirect, consequential or incidental damages arising out of use or inability to use both the hardware and software, even if Opticon has been informed about the possibility of such damages. Packaging The packing materials are not harmful for the environment. We recommend that you save all packing material, as it should be used whenever you need to transport your scanner (eg. for service). Damage caused by improper repacking is not covered by the warranty. Trademark Trademarks used are property of their respective owners.

Uii

Page 4

OPTICON Universal menu book TABLE OF CONTENTS Introduction .............................................U1

1.

Defaults ....................................................U5

2.

Interface ...................................................U7

3.

2.1. RS232 options ..................................... U8 2.1.1. Baud rate settings................................ U9 2.1.2. Data, parity, stop bits ......................... U10 2.1.3. Handshaking...................................... U11 2.1.4. Intercharacter delay for RS232 .......... U14 2.2. Keyboard wedge/USB options ........... U15 2.2.1. Keyboard layout ................................. U16 2.2.2. Special options .................................. U18 2.2.3. Intercharacter delay for wedges/USB ...................................... U19

4.

String options........................................ U83

4.1.

Case conversion .................................U84

4.2. Set prefix and suffix ............................U85 4.2.1 Set prefix ............................................U90 4.2.2. Set suffix.............................................U93

2.3. Wireless options ................................ U20 2.3.1. Bluetooth address.............................. U21 2.3.2. Bluetooth security .............................. U23 2.3.3. Trigger connection options................. U24 2.3.4. Trigger disconnect options................. U26 2.3.5. Auto disconnect options..................... U27 2.3.6. Auto reconnect options ...................... U28 2.3.7. Wireless power saving ....................... U29 2.3.8. Memorizing ........................................ U30

4.3.1. Direct input keyboard keys .................U96 4.3.2. Direct input character misc. ................U99 4.3.3. Direct input numeric..........................U102 4.3.4. Direct input character .......................U103 4.3.5. Direct input lower case character .....U105 4.3.6. Direct input control character............U107 4.3.7. Direct input code id/length ................U110 5.

3.

Code options .........................................U33

Read options ....................................... U111

5.1. Read mode options ..........................U112 5.1.1. Multiple read reset time ....................U114 5.1.2. Quiet zone options............................U115 5.1.3. Auto trigger options ..........................U116

3.1. Setting of readable codes .................. U34 3.1.1. Enabling a single read. Code............. U35 3.1.2. Enabling of readable codes ............... U38 3.2.

Code options (continued)

3.3.19. Options for Codablock F .....................U76 3.3.20. Options for DataMatrix........................U76 3.3.21. Options for Aztec ................................U77 3.3.21. Options for Chinese Sensible code ....U78 3.3.22. Options for QR Code ..........................U79 3.3.23. Options for Micro QR Code ................U80 3.3.24. Options for Maxicode..........................U80 3.3.25. Options for PDF417............................U81 3.3.26. Options for MicroPDF417 ...................U81

Setting of number of characters......... U42

3.3. Setting code specific options ............. U46 3.3.1. Options for UPC-A ............................. U47 3.3.2. Options for UPC-E ............................. U48 3.3.3. Options for EAN-13 and EAN-8 ......... U50 3.3.4. Options for Code 39 and It.Pharm. .... U52 3.3.5. Options for Codabar .......................... U55 3.3.6. Options for 2of5 and S-Code ............. U59 3.3.7. Options for IATA ................................. U61 3.3.8. Options for MSI/Plessey .................... U62 3.3.9. Options for Telepen............................ U64 3.3.10. Options for UK/Plessey...................... U65 3.3.11. Options for Code 128 and GS1-128 .. U66 3.3.12. Options for Code 93........................... U68 3.3.13. Options for Code 11........................... U70 3.3.14. Options for Korean Postal Authority... U71 3.3.15. Options for Intelligent Mail Barcode... U72 3.3.16. Options for POSTNET ....................... U72 3.3.17. Options for GS1 Databar ................... U73 3.3.18. Options for Composite Codes............ U74

5.2. 5.3. 5.4. 5.5. 5.6.

Read time options.............................U116 Power control....................................U118 Redundancy .....................................U119 Positive and negative bar codes .......U120 Floodlight and aiming options...........U121

6.

Indicator options................................. U123

6.1.

Buzzer settings .................................U124

6.2.

Good read LED.................................U126

7.

Miscellaneous ..................................... U127

7.1.

Diagnostics .......................................U127

7.2.

Serial configuration support..............U128 Appendix.............................................. U131

A. B. C.

Uiii

Trouble shooting ...............................U131 Glossary of terms .............................U132 Example codes .................................U136

Table of contents

0.

Page 5

OPTICON Universal menu book TABLE OF FIGURES 0.

3.

Introduction

2.

Interface

Fig. 2.01. RS232 options DB25 ......................U8 Fig. 2.02. RS232 options DB25 ......................U8 Fig. 2.03. Data, parity, stop bits ....................U10 Fig. 2.04. HandShaking Busy/Ready ............U11 Fig. 2.05. HandShaking Modem mode .........U11 Fig. 2.06. HandShaking ACK/NAK................U12 Fig. 2.07. HandShaking ACK/NAK no response ..................................U12 Fig. 2.08. Power saving table ........................U29 3.

Code options (continued)

Fig. 3.27. Options for 2of5 and S-Code: Industrial 2of5, Interleaved 2of5, S-Code, Matrix 2of5, Chinese Post Matrix 2of5..............U59 Fig. 3.28. Options for IATA ............................U61 Fig. 3.29. Options for MSI/Plessey ...............U62 Fig. 3.30. Options for Telepen.......................U64 Fig. 3.31. Options for UK/Plessey.................U65 Fig. 3.32. Options for Code 128....................U66 Fig. 3.33. Options for GS1-128 .....................U66 Fig. 3.34. Options for Code 93......................U68 Fig. 3.35. Options for Code 11......................U70 Fig. 3.36. Options for Korean Postal Authority code...............................U71 Fig. 3.37. Options for Intelligent Mail Barcode ........................................U72 Fig. 3.38. Options for POSTNET ..................U72 Fig. 3.39. Options for GS1 Databar, GS1 Databar Limited ....................U73 Fig. 3.40. Options for GS1 Databar Expanded................U73 Fig. 3.41. Options for Composite A...............U74 Fig. 3.42. Options for Composite B...............U74 Fig. 3.43. Options for Composite C...............U74 Fig. 3.44. Combined options for Composite Codes .........................U74 Fig. 3.45. Options for Codablock F ...............U76 Fig. 3.46. Options for DataMatrix ..................U77 Fig. 3.47. Options for Aztec ..........................U77 Fig. 3.48. Options for Chinese Sensible codeU78 Fig. 3.48. Options for QR Code ....................U79 Fig. 3.49. Options for Micro QR Code...........U80 Fig. 3.50. Options for Maxicode ....................U80 Fig. 3.51. Options for PDF417 ......................U81 Fig. 3.52. Options for MicroPDF417 .............U81

Fig. 0.01. Menu labels.....................................U1 Fig. 0.02. Configuring via the menu book .......U2 Fig. 0.03. Opticonfigure...................................U3

Code options

Fig. 3.00. Code translations and relations ....U33 Fig. 3.01. Enabling a single readable code: Symbology only.............................U34 Fig. 3.02. Enabling a single readable code: Special variation............................U34 Fig. 3.03. Enabling a single readable code: New family name...........................U34 Fig. 3.04. Enabling of readable codes ..........U38 Fig. 3.05. Enabling of readable codes addition .........................................U38 Fig. 3.06. Setting Fixed length ON all codes........................................U42 Fig. 3.07. Setting Minimum length table........U43 Fig. 3.08. Setting Fixed length ON selected codes ..............................U43 Fig. 3.09. Setting Minimum length for selected codes.........................U44 Fig. 3.10. Setting Maximum length for selected codes.........................U44 Fig. 3.11. Setting code specific options ........U46 Fig. 3.12. Options for UPC-A ........................U47 Fig. 3.13. Options for UPC-A, +2, +5 ............U47 Fig. 3.14. Options for UPC-E ........................U48 Fig. 3.15. Options for UPC-E, +2, +5 ............U48 Fig. 3.16. Options for EAN-13.......................U50 Fig. 3.17. Options for EAN-13, +2, +5...........U50 Fig. 3.18. Options for EAN-8.........................U50 Fig. 3.19. Options for EAN-8, +2, +5.............U50 Fig. 3.20. Options for Code 39......................U52 Fig. 3.21. Options for Italian Pharmaceutical U53 Fig. 3.22. Options for Tri-Optic ......................U53 Fig. 3.23. Options for Codabar......................U55 Fig. 3.24. Options for ABC Code ..................U55 Fig. 3.25. Options for CX Code.....................U55 Fig. 3.26. Options for Codabar......................U56

4.

String options

Fig. 4.01. String options................................U83 Fig. 4.02. Case conversion ...........................U84 Fig. 4.03. Set prefix and suffix ......................U85 Fig. 4.04. OPTICON Code identifiers ...........U86 Fig. 4.05. AIM/ISO15424 Code identifiers ....U87 Fig. 4.06. Modifiers for Code 39....................U87 Fig. 4.07. Modifiers for Codabar ...................U88 Fig. 4.08. Modifiers for Interleaved 2of5 .......U88 Fig. 4.09. Modifiers for IATA ..........................U88 Fig. 4.10. Modifiers for MSI/Plessey .............U88 Fig. 4.11. Modifiers for Telepen.....................U88 Fig. 4.12. Modifiers for Code 11....................U89 Fig. 4.13. Modifiers for Codablock F .............U89 Fig. 4.14. Modifiers for DataMatrix................U89 Fig. 4.15. Modifiers for Aztec ........................U89 Fig. 4.16. Modifiers for QR Code ..................U89 Fig. 4.17. Modifiers for Maxicode..................U89

Uiv

Page 6

OPTICON Universal menu book

5.

Read options

6.

Indicator options

Fig. 6.01. Buzzer settings........................... U124 6.

Diagnostics

Fig. 7.01. Serial configuration support ....... U128 Appendix A Trouble Shooting

Fig. A.01. Trouble shooting......................... U131 Appendix C Example Codes

Fig. C.01. UPC-A, UPC-A +2, UPC-A +5, ................................. U136 Fig. C.02. UPC-E, UPC-E +2, UPC-E +5, UPC-E1, UPC-E1 +2, UPC-E1 +5,................................ U136 Fig. C.03. EAN-13 and EAN-8: EAN-13 (ISBN), EAN-13 +2, EAN-13 +5, EAN-8 EAN-8 +2, EAN-8 +5 ................................... U137 Fig. C.04. Code 39 and It.Pharm.: Code 39 Code 39 Full ASCII Code 39 Italian Pharmaceutical (Full Italian Pharmaceutical) Tri-Optic...................................... U137 Fig. C.05. Codabar Codabar ABC Codabar CX ............................... U138 Fig. C.06. 2of5 and S-Code: Industrial 2of5, Interleaved 2of5, S-Code, Matrix 2of5, Chinese Post Matrix 2of5 ........... U138 Fig. C.07. IATA ............................................ U139 Fig. C.08. MSI/Plessey ............................... U139 Fig. C.09. Telepen....................................... U139 Fig. C.10. UK/Plessey................................. U139 Fig. C.11. Code 128 and GS1-128 ............. U139 Fig. C.12. Code 93...................................... U139 Fig. C.13. Code 11...................................... U139 Fig. C.14. Korean Postal Authority code ..... U139 Fig. C.15. Intelligent Mail Barcode.............. U140 Fig. C.16. POSTNET .................................. U140

Uv

Table of contents

Fig. C.17. GS1 Databar GS1 Databar stacked GS1 Databar truncated GS1 Databar Limited GS1 Databar Expanded..............U140 Fig. C.18. Composite Codes Composite Component A Composite Component B Composite Component C............U140 Fig. C.19. Codablock F ................................U141 Fig. C.20. DataMatrix...................................U141 Fig. C.21. Aztec Aztec Runes................................U141 Fig. C.22. Chinese Sensible code ...............U141 Fig. C.23. QR Code .....................................U141 Fig. C.24. Micro QR Code ...........................U141 Fig. C.25. Maxicode.....................................U141 Fig. C.26. PDF417.......................................U142 Fig. C.27. MicroPDF417 ..............................U142

Fig. 5.01. Multiple read reset time.............. U114

Page 7

OPTICON Universal menu book

Uvi

Page 8

OPTICON Universal menu book

INTRODUCTION This menu book is intended for setting up your bar code reader to optimize its performance for your particular application. When the required options have been configured, they remain in the reader, even after power down. The reader can be returned to factory default by reading the default label.

0 Introduction

Menu labels The reader must be set by reading the bar code labels in the menu table. The layout of the table is explained in next figure 0.01.

Fig. 0.01. Menu labels optional setting factory default setting

Enter mode

Save mode serial commands configuration parameters

Besides options, some chapters have commands. The commands need to be scanned directly, without reading the “SET” and “END” labels. The commands are executed directly and, unlike options, are not stored in non volatile memory.

U1

Page 9

OPTICON Universal menu book

• 5: Use chapter 5 to select the read options to your preference. These options affect the read mode, read time, trigger and redundancy.

Configuring via the menu book To configure the required options proceed as follows: • scan the SET label • scan the required option(s) • scan the END label After scanning the END label, the new settings are stored in non volatile memory.

• 6: Use chapter 6 to select the indicator options you prefer. These options affect the operation of the buzzer and good read LED. * The reader will now operate to your personal preference.

Recommended steps to follow for quick configuration After checking your connection you are ready to start the configuration of your reader.

See figure 0.02.

• Check connection: Ensure that the power is disconnected from your equipment before you connect the reader. After connecting the data cable, the power can be applied to the equipment and the reader.

Fig. 0.02. Recommended Steps

Power OFF

• 1: Use chapter 1 to set the correct default for your reader. * The reader is now in factory default.

Connect reader Power ON

• 2: Use chapter 2 to optimize the interface. * The reader is now able to read bar codes and transmit the data.

Set Default (1)

• 3: Use chapter 3 to optimize the reader for the type of bar codes you use. Set the readable codes first and then the options for each of these codes. * The reader is now able to read the codes you selected, validate the data using length and check digit and transmit that part of the data you specified.

Optimize interface (2) Optimize symbologies (3) Set string options (4) Set read options (5)

• 4: Use chapter 4 to select the string options for your application. These include transmission of code length, conversion of upper and lower case and setting a prefix and suffix. * The reader can now read and transmit the data in the required format.

Set indicator options (6)

U2

Page 10

OPTICON Universal menu book

• transmit <ESC><Command string 1><CR> • transmit <ESC><Command string 2><CR> • transmit <ESC><Command string n><CR> • transmit <ESC>Z2<CR> <ESC> <ESC> is the ASCII escape character (Hex 1B).

The characters transmitted must be separated by an intercharacter delay to allow the reader to process each character received and to execute the command string.

<Command string> <Command string> is the ASCII command with its parameters as would be scanned from the menu book, i.e. <ESC>M41B<CR> configures the ASCII control code <STX> as the prefix for Code 39. Example in hexadecimal format: 1B 4D 34 31 4B ØD Each 3-character command should be preceded with the '[' character (Hex 5B) i.e. <Esc>[BCC<CR> is used to enable Data Matrix. Each 4-character command should be preceded with the ']' character (Hex 5D) i.e. <Esc>]DIAU<CR> is used to disable auto connect.

Configuring via OptiConfigure OptiConfigure is the interactive Universal menu book version. With OptiConfigure it is possible to create your own personal setup sheet online. OptiConfigure supports Opticon bar code readers which can be configured with this Universal menu book. In addition OptiConfigure offers product specific and less often used menu labels. Based on the product and software version selected, OptiConfigure will show these specific options. OptiConfigure can be accessed via the Opticon home page (www.opticon.com). From there select the OptiConfigure button.

<CR> <CR> is the ASCII CR character (Hex ØD).

Fig. 0.03. Opticonfigure

Z2 Some options are not immediately active, like baud rate settings. Most other options are immediately active, but the command Z2 must be send to store the settings to non volatile memory.

http://opticonfigure.opticon.com/ Set up your personal configuration

Universal menu book on-line bar code configuration and commands application

U3

0 Introduction

The following commands may be used to: Command B sound a good read beep Command E sound an error beep Command G motor off Command H motor on Command L switch on good read LED Command N switch on bad read LED Command O switch on both LEDs Command Y de-trigger the reader Command Z trigger the reader Command P disable the laser Command Q enable the laser