Page 17
Manual No. 25-ULPNMU01-01
LPN1736 Omni-Directional Laser Scanner
4. Be sure the PC is in a program or application (for example, WordPad) that will accept input from the serial port. Reset All Defaults -- RS-232 Our scanners are shipped with factory default settings that represent the settings most commonly used by our customers. In most applications, the scanner will work right out of the box without the need for additional programming. At any time you can return the scanner back to the factory default settings by scanning the “Reset All Defaults -RS232” programming bar code. Remember that before scanning any programming codes, you must put the scanner into the programming mode by scanning the Start/Stop Programming Mode bar code. You must also scan this bar code, to exit the programming mode.
V3
(U2) Reset all Defaults
Reset All Defaults – RS232 You can also reset the scanner to the factory defaults by typing the following sequence on the keyboard (Esc) U2 (CR)
RS-232C Communication Parameters Handshaking Protocol
Q1
No Handshaking (P0) DEFAULT
Page 17
Page 18
Manual No. 25-ULPNMU01-01
LPN1736 Omni-Directional Laser Scanner
Handshaking Protocols . . . continued
Q!
ACK / NAK (P3)
[H
Xon / Xoff
(ZG)
Flow Control Time
J1
Unlimited (I0) DEFAULT
Page 18
Page 19
Manual No. 25-ULPNMU01-01
LPN1736 Omni-Directional Laser Scanner
Flow Control . . . Continued
Flow Control = 100ms (I1)
J2
Flow Control = 100ms (I1)
J3
Flow Control = 200ms (I2)
Flow Control = 200ms (I2)
Flow Control = 400ms (I3)
J!
Flow Control = 400ms (I3)
Page 19
Page 20
Manual No. 25-ULPNMU01-01
LPN1736 Omni-Directional Laser Scanner
Baud Rate
L8
Baud Rate = 19200 (K7)
Baud Rate = 19200 (K7)
Baud Rate = 9600 (K6) DEFAULT
L7
Baud Rate = 9600 (K6) DEFAULT
L6
Baud Rate = 4800 (K5)
Baud Rate = 4800 (K5)
Page 20
Page 21
Manual No. 25-ULPNMU01-01
LPN1736 Omni-Directional Laser Scanner
Baud Rate . . . continued
L5
Baud Rate = 2400 (K4)
Baud Rate = 2400 (K4)
Baud Rate = 1200 (K3)
L!
Baud Rate = 1200 (K3)
L3
Baud Rate = 600 (K2)
Baud Rate = 600 (K2)
Page 21
Page 22
Manual No. 25-ULPNMU01-01
LPN1736 Omni-Directional Laser Scanner
Data Bits
M1
7 Data Bits (L0)
7 Data Bits (L0)
8 Data Bits (L1) DEFAULT
M2
8 Data Bits (L1) DEFAULT
Page 22
Page 23
Manual No. 25-ULPNMU01-01
LPN1736 Omni-Directional Laser Scanner
Stop Bits
M6
1Stop Bit (L5) DEFAULT
1 Stop Bit (L5) DEFAULT
2 Stop Bits (L6)
M7
2 Stop Bits (L6)
Page 23
Page 24
Manual No. 25-ULPNMU01-01
LPN1736 Omni-Directional Laser Scanner
Parity
M!
Even Parity (L3)
Even Parity (L3)
Odd Parity
(L4)
M5
Odd Parity (L4)
M3
Mark No Parity (L2) DEFAULT
Mark No Parity (L2) DEFAULT
Page 24
Page 25
Manual No. 25-ULPNMU01-01
LPN1736 Omni-Directional Laser Scanner
Chapter 3 USB Interface This chapter contains information on setting up your scanner with an USB interface. The RS232 scanner cable is terminated in a Type A USB connector. The external power supply (+5VDC) is necessary. There is a pig tail adapter with the power supply jack leading to the USB connector
Plug the scanner into a USB port on your host computer. The PC must be running Windows 98 (or iMac Rev A) or higher. The computer will sense the presence of the scanner and load any required software driver. Reset All Defaults - USB
TV
Reset all defaults - USB (SU)
Reset All Defaults USB (SU)
Page 25