Page 61

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

25. Buzzer Operation Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

T0

Volume = Maximum

U1

T1

Volume = Upper Mid-range

U2

T2

Volume = Lower Mid-range

U3

T3

Volume = Minimum

U!

W0

Disable buzzer

X1

W1

Enable buzzer at 3kHz

X2

W2

Enable buzzer at 3kHz with 2.5kHz interval

X3

W3

Enable buzzer at 3kHz with 4kHz interval

X!

W4

Buzzer duration 0.10 sec

X5

W5

Buzzer duration 0.20 sec

X6

W6

Buzzer duration 0.40 sec

X7

W7

Buzzer duration 0.05 sec

X8

W8

Enable buzzer

X9

%

%

%

%

Page 57

Page 62

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

26. Positive & Negative Bar Codes Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

V2

Positive bar code only (black bars/white spaces)

W3

V3

Negative bar codes

W!

V4

Both positive & negative bar code

W5

%

27. Setting the Trigger & Auto-Trigger Functions Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

S7

Disable the trigger function / laser is ON continuously

T8

S8

Enable the trigger function /laser is OFF until trigger is activated or “pulled”

T9

+F

Disable Auto-trigger

,G

+I

Enable Auto-trigger

,J

Z

Activate the trigger; turns on the laser

Use as Computer Command

% %

The Trigger function is enabled in the default setting. This means that the laser is “OFF” until triggered by command or via the Auto-Trigger which is also enabled in the default setting. For some applications, you may wish the laser to operate continuously, although this is not recommended. This can be done by disabling the Trigger function using the S7 command. Once in the “Trigger Disabled” mode, the laser is on continuously. The software trigger is actuated by downloading and <ESC> Z <CR> computer command from the host. (See Scanner Timeout to establish the length of time the scanning light remains ON after the trigger is activated.) A hardware trigger is not available with this scanner.

Page 58

Page 63

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

28. Selecting the Read Mode Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

S0

Single Read Mode (Trigger enabled mode only)

T1

S1

Multiple Read Mode

T2

S2

Continuous Read Mode

T3

%

The operation of the scanner in the various read modes is described in the table below. The “Continuous Read” mode is helpful in positioning the scanner for optimum reading. In “Continuous Read,” the scanner’s buzzer functions like a Geiger counter, sounding the most active at the position achieving the greatest number of good reads.

Mode

Trigger Function Enabled (S8) Trigger Function Disabled (S7) After receiving a trigger pulse, scanner will read multiple, Scanner will read different bar codes different bar codes in succession in succession if they are presented Multiple until it times out. (Each read will to the read window. reset the scanner’s time out) Read Scanner may not read the same Scanner may not read the same bar bar code twice if they are code twice if they are consecutive. consecutive. (See Sect. 32) (See Sect. 32) Scanner will read the same bar code continuously after receiving Continuous Scanner will read the same bar code a trigger pulse until the label is Read continuously. removed, the laser then times out. Scanner will read only one bar code after receiving a trigger Single Same as Multiple Read mode, pulse. The scanner time out is Read above. terminated on a good read and the laser turns off.

Page 59

Page 64

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

29. Parallel Read Mode Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

+6

2 Parallel labels only

,7

+7

3 Parallel labels only

,8

+8

4 Parallel labels only

,9

30. Add-on Wait Mode (Applies to UPC/EAN only) Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

XA

Disable Add-on wait mode

YB

XB

Enable Add-on wait mode of 0.25 seconds

YC

XC

Enable Add-on wait mode of 0.50 seconds

YD

XD

Enable Add-on wait mode of 0.75 seconds

YE

%

These commands are used when UPC/EAN with add-on is enabled. The reader searches within the selected time for a valid add-on code. If a valid add-on code is found, the reader transmits the data immediately. If nothing is found behind the code, the reader will transmit the data without the add-on.

Page 60

Page 65

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

31. Scanner Timeout (Trigger Enabled Mode only) These commands, which are only applicable in the Trigger Enabled mode, establish the time-out period after the trigger pulse is received. In Single Read Mode, the time out is terminated upon a good read. In Multiple Read and Continuous Read Modes the time out is reset after any good read. Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

Y1

1 Second after triggering

Z2

Y2

2 Seconds after triggering

Z3

Y3

3 Seconds after triggering

Z!

Y4

4 Seconds after triggering

Z5

Y5

5 Seconds after triggering

Z6

Y6

6 Seconds after triggering

Z7

Y7

7 Seconds after triggering

Z8

Y8

8 Seconds after triggering

Z9

Y9

9 Seconds after triggering

Z:

YL

Read time x 10

ZM

YM

Indefinitely after triggering

ZN

%

Page 61

Page 66

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

32. Multiple Read Reset Time This option is used in conjunction with the multiple read mode. The selected time sets the period the scanners should be pointed away from a label before that same label can be decoded again. Indefinitely means that the next bar code must always be different during the time the scanner is triggered. Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

AH

Set at 50 msec

BI

AI

Set at 100 msec

BJ

AJ

Set at 200 msec

BK

AK

Set at 300 msec

BL

AL

Set at 400 msec

BM

AM

Set at 500 msec

BN

AN

Set at 600 msec

BO

AG

Set indefinitely

BH

%

Page 62

Page 67

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

33. Quiet Zone Options With this option the scanner can decode bar codes that have smaller quiet zone margins than specified for the symbology. Be careful when using this option as its use may increase the possibility of partial and ghost reads. Do not use smaller margin checks than necessary. If possible, replace the bar codes labels with others that have the correct start and end margins. Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

YN

No margin check

ZO

YO

Margin check 1/7 nominal

ZP

YP

Margin check 2/7 nominal

ZQ

YQ

Margin check 3/7 nominal

ZR

YR

Margin check 4/7 nominal

ZS

YS

Margin check 5/7 nominal

ZT

YT

Margin check 6/7 nominal

ZU

YU

Margin check normal

ZV

%

Page 63

Page 68

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

34. Redundant Decoding The Number of Redundant Decodes determines how many times the scanner must decode a bar code and obtain the same value before it will transmit the data. For example, if the redundancy is set at three times, the scanner will not transmit data until it has completed three consecutive, identical “good reads”. In the case of a poor label which generates an intermediate “no decode” within a sequence of four scans where three of the four have resulted in “good reads”, the scanner will transmit the data after the fourth scan. In other words, a “no decode” does not restart the sequence. Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

X0

Read bar code once

Y1

X1

Read bar code twice

Y2

X2

Read bar code three times

Y3

X3

Read bar code four times

Y!

BS

Read bar code five times

CT

BT

Read bar code six times

CU

BU

Read bar code seven times

CV

BV

Read bar code eight times

CW

BW

Read bar code nine times

CX

%

Page 64

Page 69

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

35. Transmitting Error Indications (Trigger Enabled only) Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

TH

Error message no label

UI

TI

Error message no decode

UJ

TG

Clear error messages for no label and no decode

UH

WD

Disable response to command

XE

WC

Enable response to command OK=ACK, ERROR=NAK

XD

WB

Buzzer Control to Command – Disable

XC

WA

Buzzer Control to Command – Enable

XB

%

%

Error Messages – No decode / no label Messages may be user defined for the “no decode” and “no label” error modes independently. Using the “Error message no label” (TH) and “Error message no decode” (TI) menu commands a maximum of 4 characters may be user specified for transmission should these errors occur.

The following process should be followed to designate these error codes: 1. Scan “START” to enter the programming mode. 2

Scan “Error message no label” (TH).

3. Scan bar codes of the desired error message characters (4 max) 4. Scan “END” to end the programming sequence.

In a similar fashion, the “Error message no decode” (TI) can be defined.

Page 65

Page 70

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

36. Good Read LED Operation Computer Command

Function /Description

Bar Code Command

(ZZ)

START/END Programming Menu

[[

T4

Good read LED disabled after decode

U5

T5

Good read LED ON after decode for .20 seconds

U6

T6

Good read LED ON after decode for .40 seconds

U7

T7

Good read LED ON after decode for .80 seconds

U8

%

Page 66