Page 41
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
10. Options for IATA Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
4H
Do not calculate check digit
5I
4J
Calculate check digit (CPN + Form + Serial)
5K
4I
Calculate check digit (Form + Serial)
5J
4K
Calculate check digit (All data)
5L
4L
Transmit check digit
5M
4M
Do not transmit check digit
5N
-X
Default Algorithm
-Y
Enables alternate decode algorithms. May improve performance on certain I 2 of 5, Code 39, Codabar or MSI/Plessey bar codes.
.Y
%
% %
.Z
The IATA code is a variable length symbology with an optional check digit and non-printable start/stop characters. The following characters are supported: Digits 0 up to 9. The checksum is calculated as the modulo seven of the data string. IATA is an acronym for International Air Transport Association. String format
CPN
Meaning of Acronym
Coupon
Number of digits (15 total)
♦ ♦ ♦
1
AC Airline Code 3
FC Form Code 2
SN Serial Number 8
CD Check Digit 1
Enable check digit check Selection of the check digit calculation Disable transmission of the check digit
Check digit calculation: If the check digit calculation is required, then the appropriate calculation method must be selected.
Page 37
Page 42
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
11. Options for Code-128 / EAN-128 Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
OF
Disable EAN-128 only
PG
JF
Enable EAN-128 only
KG
MP
Disable concatenation
NQ
MO
Enable concatenation
NP
Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
+W
Disable concatenation
,X
+V
Enable concatenation
,W
% %
12. Options for Code-93
%
Page 38
Page 43
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
13. Fixing the Number of Digits Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
H0
Disable fixed length all symbologies
I1
H1
Enable fixed length all symbologies
I2
HK
Enable fixed length for selected codes
IL
HL
Enable minimum length for selected codes
IM
HM
Enable maximum length for Selected codes
IN
%
To avoid truncation errors, the scanner can be programmed to only decode bar codes of one specific length, i.e., containing a specific number of digits. It is also possible to program the scanner to only decode bar codes of either of two specific lengths. To fix two (2) lengths (or number of digits) of bar code for all symbologies: 1. Scan “START” to enter the programming mode 2. Scan “Enable fixation(H1) for all symbologies” bar code 3. Scan a sample bar code of the desired length 4. Repeat Step #3, re-scanning the sample bar code (this may be the same as the first one) 5. Scan “END” to exit the programming mode
To fix one (1) or two (2) different lengths of bar codes for selected symbologies: 1. Scan “START” to enter the programming mode 2. Scan “Enable fixation(HK) for selected symbologies” bar code 3. Scan a sample bar code of the desired length #1 4a. Go to step 5 or 4b. Scan a sample bar code of the desired length #2 5. Scan “END” to exit the programming mode
“Fixing the Number of Digits” can only be applied to Code 39, NW-7, 2 of 5, MSI/Plessey. WPC, Code 93, IATA, Code 128 are not affected. Setting Minimum/Maximum Length This option modifies the default minimum length table. To use this option, perform the following steps: 1. Scan “START” to enter the programming mode 2. Scan “Enable minimum length for selected codes” (HL) 3. Scan bar codes of the required type and length. 4. Scan “END” to end the programming sequence. Page 39
Page 44
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
For example, if a Code 39 label of length 2 characters were scanned in Step 3 then only Code 39 labels would be checked for a minimum length of 2 characters. If a second label had been read in Step 3 (immediately following the first), then that particular symbology could have been set to different minimum character length. In a similar manner, the maximum length for selected codes can be established by using the “Enable maximum length for selected codes” (HM) command.
14. Creating a Prefix and/or Suffix Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
Z3
Display Settings including Prefix/Suffix value and length (expressed in hexidecimal format)
[[ [!
The Z3 command can be used to instruct the scanner to provide a list of its current software settings including prefixes and suffixes. The scanner can be programmed to transmit a prefix and/or suffix with the decoded data. A Prefix (or a
Example: To add the alpha character “A” as a Prefix and “B” as a Suffix to UPC-A bar code data: 1. 2. 3. 4. 5. 6.
Scan “START/END Programming Mode” Scan N1, representing a Prefix for UPC-A Scan 0A, representing the alpha character “A” Scan N6, representing a Suffix for UPC-A Scan 0B, representing the alpha character “B” Scan “START/END Programming Mode”
Suffix) is composed of up to 4 characters. The following steps are used to establish a Prefix that will be transmitted with the bar code data: 1. Scan Start 2. Scan the bar code representing the symbology to which you wish to add a Prefix 3. Scan the character(s) that will comprise the Prefix. Up to four numeric, alpha or control character(s) may be used. 4. Scan “STOP” to exit the Programming Mode.
Page 40
Page 45
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
15. Setting Prefixes (Identifying the Symbology) Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
RY
All codes
SZ
N1
UPC-A
O2
M0
UPC-A +2 or +5
N1
N2
UPC-E
O3
M1
UPC-E +2 or +5
N2
N3
EAN-13
O!
M2
EAN –13 +2 or +5
N3
N4
EAN-8
O5
M3
EAN-8 +2 or +5
N!
M4
Code 39
N5
M5
Codabar (NW-7)
N6
M6
Industrial 2 of 5
N7 CONTINUED ON NEXT PAGE..
Page 41
Page 46
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
15. Setting Prefixes (Identifying the Symbology) (continued) Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
M7
Interleaved 2 of 5
N8
M8
Code 93
N9
M9
Code 128
N:
I8
IATA
J9
N0
MSI/Plessey
O1
MB
SCode
NC
L8
Telepen
M9
Page 42
Page 47
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
16. Setting Suffixes (Identifying the Symbology) Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
RZ
All Codes
S[
N6
UPC-A
O7
O0
UPC-A +2 or +5
P1
N7
UPC-E
O8
O1
UPC-E +2 or +5
P2
N8
EAN-13
O9
O2
EAN–13 +2 or +5
P3
N9
EAN-8
O:
O3
EAN-8 +2 or +5
P!
O4
Code 39
P5
O5
Codabar (NW-7)
P6
O6
Industrial 2 of 5
P7 CONTINUED ON NEXT PAGE..
Page 43
Page 48
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
16. Setting Suffixes (Identifying the Symbology) (continued) Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
O7
Interleaved 2 of 5
P8
O8
Code 93
P9
O9
Code 128
P:
I9
IATA
J:
N5
MSI/Plessey
O6
OB
SCode
PC
L9
Telepen
M:
Page 44
Page 49
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
17. Direct Input of Numeric Characters Computer Command
Function /Description
Bar Code Command
(ZZ)
START/END Programming Menu
[[
Q0
0
R1
Q1
1
R2
Q2
2
R3
Q3
3
R!
Q4
4
R5
Q5
5
R6
Q6
6
R7
Q7
7
R8
Q8
8
R9
Q9
9
R:
Page 45
Page 50
Manual No. 25-ULPNR102-01; Mar, 2005
LMD 1135 Laser Fixed Mount Scanner
18. Direct Input of Alpha Characters
[[
0N
N
1O
A
1B
0O
O
1P
0B
B
1C
0P
P
1Q
0C
C
1D
0Q
Q
1R
0D
D
1E
0R
R
1S
0E
E
1F
0S
S
1T
0F
F
1G
0T
T
1U
0G
G
1H
0U
U
1V
0H
H
1I
0V
V
1W
0I
I
1J
0W
W
1X
0J
J
1K
0X
X
1Y
0K
K
1L
0Y
Y
1Z
0L
L
1M
0Z
Z
1[
0M
M
1N
(ZZ)
START/END Program Menu
(ZZ)
START/END Program Menu
0A
[[
Page 46