Page 81
OPTICON UNIVERSAL MENU BOOK
3.3.18. Options for Aztec
3.3.19. Options for QR Code
Aztec code is a variable size matrix symbology with selectable error correction levels.
QR code is a variable size matrix symbology with selectable error correction levels.
Maximum data capacity: Standard Aztec: • alphanumeric: 3067 characters • numeric: 3832 characters • byte: 1914 characters Aztec runes: • values 000 up to 255 ( 3 digits )
Maximum data capacity: Model 1: • alphanumeric data: 707 characters • 8-bit data: 486 characters • numeric data: 1167 characters • kanji data: 299 characters Model 2: • alphanumeric data: 4296 characters • 8-bit data: 2953 characters • numeric data: 7089 characters • kanji data: 1817 characters
Symbol size: Standard Aztec: • minimum: 15 * 15 modules • maximum: 151 * 151 modules Aztec runes: • fixed: 11 * 11 modules
Symbol size: Model 1: • minimum: 21 * 21 modules • maximum: 73 * 73 modules Model 2: • minimum: 21 * 21 modules • maximum: 177 * 177 modules
Error correction: User selectable Reed-Solomon error correction levels from 5% to 95% of data region. Additional features: • extended Channel Interpretation (ECI): support for different character sets and data interpretations • structured append: represent data in up to 26 Aztec symbols • mirror image: decode symbol in mirror reversal presentation Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent
Error correction: Four levels of Reed-Solomon error correction. Additional features: • extended Channel Interpretation (ECI, model 2 only): support for different character sets and data interpretations. • structured append: represent data in up to 16 QR Code symbols. Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent
Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • with ECI: many other character sets For string format see figure 3.43.
Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • with ECI: many other character sets For string format see figure 3.44.
Options for Aztec: • structured append time out: see chapter Read options
Fig. 3.43. Options for Aztec Aztec data (1 upto 3832 characters)
U76
Page 82
OPTICON UNIVERSAL MENU BOOK
3.3.20. Options for Micro QR Code Options for QR code: • structured append time out: see read mode options • no further options supported
Micro QR code is a compact version for the regular QR Code.
Fig. 3.44. Options for QR Code QR Code data (1 upto 7089 characters)
Symbol size: Model 1: • 11 modules Model 2: • 13 modules Model 3: • 15 modules Model 4: • 17 modules Error correction: Up to three levels of Reed-Solomon error correction for Model 4, no error correction for Model 1. Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) For string format see figure 3.45. Options Micro QR Code • no options supported
Fig. 3.45. Options for Micro QR Code Micro QR Code data (1 upto 35 characters)
U77
3 Code options
Maximum data capacity: Model 1: • numeric data: 5 characters Model 2: • alphanumeric data: 6 characters • numeric data: 10 characters Model 3: • alphanumeric data: 11 characters • 8-bit data: 9 characters • numeric data: 18 characters • kanji data: 6 characters Model 4: • alphanumeric data: 21 characters • 8-bit data: 15 characters • numeric data: 35 characters • kanji data: 9 characters
Page 83
OPTICON UNIVERSAL MENU BOOK
3.3.21. Options for Maxicode
3.3.22. Options for PDF417
Maxicode is a fixed size matrix symbology with selectable error correction levels.
PDF417 is variable size multi row (stacked) symbology with selectable error correction levels.
Maximum data capacity: • alphanumeric data: 93 characters • numeric data: 138 characters
Maximum data capacity: • text compaction: 1850 characters • byte compaction: 1108 characters • numeric compaction: 2710 characters
Symbol size: 28.14mm wide * 26.91mm high ( including quiet zones )
Symbol size: • number of row: 3 up to 90 • number of columns: 1 up to 30
Error correction: 2 levels of Reed-Solomon error correction.
Error correction: 8 levels of error correction. Option for error detection only.
Additional features: • extended Channel Interpretation (ECI): support for different character sets and data interpretations • structured append: represent data in up to 8 Maxicode symbols Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent.
Additional features: • extended Channel Interpretation (ECI): support for different character sets and data interpretations • macro PDF417: represent data in up to 99.999 PDF417 symbols • truncated PDF417: reduce some overhead to obtain smaller symbology size Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent
Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • with ECI: many other character sets For string format see figure 3.46.
Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • for macro PDF417: many other character sets For string format see figure 3.47
Options for Maxicode: • structured append time out: see read mode options • no further options supported
Options for PDF417: • macro PDF417 timeout ( same as Structured append time out ): see read mode options • no further options available
Fig. 3.46. Options for Maxicode Maxicode data (1 upto 138 characters)
Fig. 3.47. Options for PDF417 PDF417 data (1 upto 2710 characters)
U78
Page 84
OPTICON UNIVERSAL MENU BOOK
3.3.23. Options for MicroPDF417 MicroPDF417 is variable size multi row (stacked) symbology with fixed error correction levels.
Fig. 3.48. Options for MicroPDF417 MicroPDF417 data (1 upto 366 characters)
Maximum data capacity: • text compaction: 250 characters • byte compaction: 150 characters • numeric compaction:366 characters Symbol size: • number of row: 4 up to 44 • number of columns: 1 up to 4
3 Code options
Error correction: Number of error correction codewords is dependent of symbol size and can not be changed. Additional features: • extended Channel Interpretation (ECI): support for different character sets and data interpretations • macro MicroPDF417 ( structured append mode ): represent data in up to 99.999 MicroPDF417 symbols Support for these options is reader dependent. The supported character set and the maximum decodable number of characters, is reader dependent Encodable characters: • ASCII values 0 - 127 ( ISO 646 ) • ASCII values 128 - 255 ( ISO 8859-1, Latin alphabet No. 1, extended ASCII ) • for macro MicroPDF417: many other character sets For string format see figure 3.48. Options for MicroPDF417: • macro MicroPDF417 timeout ( same as Structured append time out ): see read mode options • no further options available
U79
Page 85
OPTICON UNIVERSAL MENU BOOK
U80
Page 86
OPTICON UNIVERSAL MENU BOOK
4. STRING OPTIONS This chapter describes the alterations which can be made to the format of the transmitted data string. Options available are: • case conversion • transmission of a code identifier • transmission of the code length • transmission of a prefix • transmission of a suffix The string format is transmitted as in figure 4.01.
4 String options
The bar code data has the format as described in chapter ‘Code Options’.
Fig. 4.01. String Options preamble prefix bar code data suffix postamble
Note: Preamble is the same as common prefix. Postamble is the same as common suffix.
U81
Page 87
OPTICON UNIVERSAL MENU BOOK
4.1. Case conversion The bar code data may be converted to either lower or upper case or the case may be exchanged. These options may be used if the user of a wedge has a preference to leave for instance the CAPSLOCK on or if the host requires upper case characters only. See figure 4.02.
Fig. 4.02. Case conversion
AbCd
Test string
AbCd
No case conversion
ABCD
Convert to upper case abcd
Convert to lower case aBcD
Exchange case
SET
_ZZ_
No case conversion
YZ
_YZ_
Convert to upper case
YW
_YW_
Convert to lower case
YX
_YX_
Exchange case
YY
_YY_
END
_ZZ_
U82
Page 88
OPTICON UNIVERSAL MENU BOOK
If the direct input keyboard key <return> from this chapter is selected then the result is a <carriage return> or <Enter> key. See figure 4.03.
4.2. Set prefix and suffix A prefix and suffix of maximum 4 direct input entries each may be included in front and at the end of the string respectively.
Fig. 4.03. Set prefix and suffix
Bar code readers with an RS232 interface may be programmed with all 128 ASCII characters. Keyboard wedges may additionally be programmed with the special keys supported by the keyboard, e.g. function keys. Default settings are: • RS232: Prefix - None, Suffix - ^M (CR) • Wedge: Prefix - None, Suffix - return
PREFIX
SUFFIX
SET
SET
Set prefix Code 39
Set suffix Code 128
C
END
9
SET
:
Set suffix All
END
^M (CR) END
Preamble and postamble: A preamble is transmitted before the prefix and can contain up to 8 direct input characters. A postamble is transmitted after the suffix and can contain up to 8 direct input characters. A preamble and postamble will be transmitted for all symbologies. By default, the preamble and postamble is empty.
Bar code readers which do not support a different prefix or suffix for each symbology have to make use of <ALL>. How to clear a prefix or suffix: To clear the suffix for example for Code 128 scan the following labels: <SET> <Set suffix Code 128> <END>
Code identification Opticon: A code identification and the code length may be included as a prefix or suffix. The direct input 'code identifier' provides a quick method of programming in addition to programming a separate prefix or suffix for each bar code type. See figure 4.04.
How to set a suffix for all symbologies: To configure for example the suffix <CR> for all symbologies scan the following labels: <SET> <Set suffix ALL> <^M (CR)> <END>
Code identification AIM/ISO: The Code identifier will be transmitted in the ISO 15424 format : ]cm, where: • ] is ASCII value decimal 93 • c is code character • m is modifier character(s) For a detailed list of the modifier character 'm' and the AIM-ID’s, refer to the ISO15424 standard. See figure 4.05.
Note that this last example is for an RS232 interface. For a wedge interface a ^M (CR) results in the key combination <ctrl>M.
U83
4 String options
3
How to set a prefix or a suffix: To configure a prefix for example for Code-39 as C39: scan the following labels from this current chapter ‘String Options’: <SET> <Set prefix Code 39> <C> <3> <9> <:> <END>
Page 89
OPTICON UNIVERSAL MENU BOOK
In case the modifier is an asterix (*), the value depends on the options of the symbology or on the configured Code options. For details refer to their own respective modifier tables. See figures 4.06 up to 4.16.
Fig. 4.04. Set prefix and suffix OPTICON Code identifiers
Code length: The code length is transmitted as 2 digits, representing the decimal number of data characters transmitted, excluding prefix and suffix characters. For 2D bar codes the code length is transmitted as 6 digits. It is also possible to send for both 1D and 2D codes the length as 6 digits.
UPC-A UPC-A +2 UPC-A +5 UPC-E UPC-E +2 UPC-E +5 EAN-13 EAN-13 +2 EAN-13 +5 EAN-8 EAN-8 +2 EAN-8 +5 Code 39 Code 39 Full ASCII Italian Pharmaceutical Codabar Codabar ABC Codabar CX Industrial 2of5 Interleaved 2of5 S-Code Matrix 2of5 IATA MSI/Plessey Telepen UK/Plessey Code 128 EAN-128 Code 93 Code 11 Korean Postal Authority code RSS CC-A CC-B CC-C DataMatrix Aztec QR code Maxi Code MicroPDF417 PDF417
These direct input characters count as 1 entry of the 4 permissible entries for a prefix or suffix. Example: If you want to configure the prefix <code identifier>:<code length>: scan the following labels: <SET> <Set prefix all> <Code identification> <:> <Code length> <:> <END> If you want to use the code identifiers, but need another code identifier for Code 39, you scan the following labels: <SET> <Set prefix all> <Code identification> <:> <Set prefix Code 39> <$> <:> <END>
U84
- C - F - G - D - H - I - B - L - M - A - J - K - V - W - Y - R - S - f - O - N - g - Q - P - Z - d - a - T - T - U - b - c - y - m - n - l - t - o - u - v - s r
Page 90
OPTICON UNIVERSAL MENU BOOK
Fig. 4.05. Set prefix and suffix
Fig. 4.06. Modifiers for Code 39 AIM/ISO15424 Code identifiers for :
AIM/ISO15424 Code identifiers
]AIM-ID *(Modifier table)
Symbology
Telepen Code 128 EAN-128 Code 93 Code 11 Korean Postal Authority code RSS RSS with CC-A RSS with CC-B EAN-128 with CC-C CC-A (transmitted separately) CC-B (transmitted separately) CC-C (transmitted separately) PDF417 MicroPDF417 Data Matrix Aztec QR Code Maxicode
-
Normal Code 39 (D5) Not check CD (C1) Transmit CD (D9) Normal Code 39 (D5) Check CD (C0) Transmit CD (D9) Normal Code 39 (D5) Not check CD (C1) Not transmit CD (D8) Normal Code 39 (D5) Check CD (C0) Not transmit CD (D8) Full ASCII Code 39 (D4) or Full ASCII Code 39 if pos. (+K) Not check CD (C1) Transmit CD (D9) Full ASCII Code 39 (D4) or Full ASCII Code 39 if pos. (+K) Check CD (C0) Transmit CD (D9) Full ASCII Code 39 (D4) or Full ASCII Code 39 if pos. (+K) Not check CD (C1) Not transmit CD (D8) Full ASCII Code 39 (D4) or Full ASCII Code 39 if pos. (+K) Check CD (C0) Not transmit CD (D8)
]E0
]E3
]E4 ]E7 ]A*
(4.06)
]X0 ]F*
(4.07)
]X0 ]S0 ]I* (4.08) ]X0 ]R* ]M* ]X0 ]B* ]C0 ]C1 ]G0 ]H* ]X0 ]X0 ]e0
(4.09) (4.10) (4.11)
(4.12)
]e1
]L0 ]d* ]z* ]Q* ]U*
(4.13) (4.14) (4.15) (4.16)
U85
A* ]AIM-ID ]A0
]A1
]A2
]A3
]A4
]A5
]A6
]A7
4 String options
UPC-A EAN-13 UPC-E UPC-A +2 UPC-A +5 UPC-E +2 UPC-E +5 EAN-13 +2 EAN-13 +5 EAN-8 EAN-8 +2 EAN-8 +5 Code 39 Code 39 Full ASCII Tri-Optic Code 39 It. Pharmaceutical Codabar Codabar ABC Codabar CX Industrial 2of5 Interleaved 2of5 S-Code Matrix 2of5 IATA MSI/Plessey
Code options